An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines
The paper presents an improved stator flux estimation technique based on a voltage model with some form of low pass filtering. In voltage model-based stator flux estimation, a low-pass (LP) filter is normally used instead of a pure integrator to avoid the integration drift problem due to DC offset,...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
2000
|
Subjects: | |
Online Access: | http://eprints.utm.my/1933/1/NikRumzi2000_AnImprovedStatorFluxEstimationInSteady.pdf |
_version_ | 1825909151997362176 |
---|---|
author | Idris, Nik Rumzi Yatim, A.H.M |
author_facet | Idris, Nik Rumzi Yatim, A.H.M |
author_sort | Idris, Nik Rumzi |
collection | ePrints |
description | The paper presents an improved stator flux estimation technique based on a voltage model with some form of low pass filtering. In voltage model-based stator flux estimation, a low-pass (LP) filter is normally used instead of a pure integrator to avoid the integration drift problem due to DC offset, noise or measurement error present in the back electromotive force (EMF). In steady state condition, the LP filter estimator will degrade the performance and efficiency of the direct torque control (DTC) drive system since it introduces magnitude and phase errors, thus resulting in an incorrect voltage vector selection. The stator flux steady state error between the LP filter and a pure integrator estimator techniques is derived and its effect on the steady state DTC drive performance is analyzed. A simple method is proposed to compensate for this error which results in a significant improvement in the steady state drive performances. Simulation based on this technique is given and it is verified by experimental results. |
first_indexed | 2024-03-05T17:57:55Z |
format | Article |
id | utm.eprints-1933 |
institution | Universiti Teknologi Malaysia - ePrints |
language | English |
last_indexed | 2024-03-05T17:57:55Z |
publishDate | 2000 |
record_format | dspace |
spelling | utm.eprints-19332010-06-01T02:59:41Z http://eprints.utm.my/1933/ An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines Idris, Nik Rumzi Yatim, A.H.M TK Electrical engineering. Electronics Nuclear engineering The paper presents an improved stator flux estimation technique based on a voltage model with some form of low pass filtering. In voltage model-based stator flux estimation, a low-pass (LP) filter is normally used instead of a pure integrator to avoid the integration drift problem due to DC offset, noise or measurement error present in the back electromotive force (EMF). In steady state condition, the LP filter estimator will degrade the performance and efficiency of the direct torque control (DTC) drive system since it introduces magnitude and phase errors, thus resulting in an incorrect voltage vector selection. The stator flux steady state error between the LP filter and a pure integrator estimator techniques is derived and its effect on the steady state DTC drive performance is analyzed. A simple method is proposed to compensate for this error which results in a significant improvement in the steady state drive performances. Simulation based on this technique is given and it is verified by experimental results. 2000-10-08 Article PeerReviewed application/pdf en http://eprints.utm.my/1933/1/NikRumzi2000_AnImprovedStatorFluxEstimationInSteady.pdf Idris, Nik Rumzi and Yatim, A.H.M (2000) An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines. Industry Applications Conference, 2000. Conference Record of the 2000 IEEE , 3 . pp. 1353-1359. |
spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Idris, Nik Rumzi Yatim, A.H.M An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines |
title | An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines |
title_full | An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines |
title_fullStr | An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines |
title_full_unstemmed | An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines |
title_short | An Improved Stator Flux Estimation In Steady State Operation For Direct Torque Control Of Induction Machines |
title_sort | improved stator flux estimation in steady state operation for direct torque control of induction machines |
topic | TK Electrical engineering. Electronics Nuclear engineering |
url | http://eprints.utm.my/1933/1/NikRumzi2000_AnImprovedStatorFluxEstimationInSteady.pdf |
work_keys_str_mv | AT idrisnikrumzi animprovedstatorfluxestimationinsteadystateoperationfordirecttorquecontrolofinductionmachines AT yatimahm animprovedstatorfluxestimationinsteadystateoperationfordirecttorquecontrolofinductionmachines AT idrisnikrumzi improvedstatorfluxestimationinsteadystateoperationfordirecttorquecontrolofinductionmachines AT yatimahm improvedstatorfluxestimationinsteadystateoperationfordirecttorquecontrolofinductionmachines |