Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse
Surges resulting from lightning strikes could propagate not only into the power line but also into a low voltage line such as the telecommunication system and could cause damage to the equipment. In order to protect this highly sensitive equipment, a telephone lightning protector (MOV) has to be ins...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
1998
|
Subjects: | |
Online Access: | http://eprints.utm.my/1974/1/Yaacob1998_Voltage-currentCharacteristicsOfMetalOxide.pdf |
_version_ | 1825909159936131072 |
---|---|
author | Yaacob, M.M. Ghani, R.A. |
author_facet | Yaacob, M.M. Ghani, R.A. |
author_sort | Yaacob, M.M. |
collection | ePrints |
description | Surges resulting from lightning strikes could propagate not only into the power line but also into a low voltage line such as the telecommunication system and could cause damage to the equipment. In order to protect this highly sensitive equipment, a telephone lightning protector (MOV) has to be installed in the telephone set. Since the natural characteristics of lightning are a multiple stroke/flash, the response of the protector under this condition has to be investigated. This paper presents the experimental studies on the voltage and current characteristic of the MOV under the application of multiple lightning impulse voltage and current |
first_indexed | 2024-03-05T17:58:02Z |
format | Article |
id | utm.eprints-1974 |
institution | Universiti Teknologi Malaysia - ePrints |
language | English |
last_indexed | 2024-03-05T17:58:02Z |
publishDate | 1998 |
record_format | dspace |
spelling | utm.eprints-19742010-06-01T03:00:00Z http://eprints.utm.my/1974/ Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse Yaacob, M.M. Ghani, R.A. TK Electrical engineering. Electronics Nuclear engineering Surges resulting from lightning strikes could propagate not only into the power line but also into a low voltage line such as the telecommunication system and could cause damage to the equipment. In order to protect this highly sensitive equipment, a telephone lightning protector (MOV) has to be installed in the telephone set. Since the natural characteristics of lightning are a multiple stroke/flash, the response of the protector under this condition has to be investigated. This paper presents the experimental studies on the voltage and current characteristic of the MOV under the application of multiple lightning impulse voltage and current 1998-06-07 Article PeerReviewed application/pdf en http://eprints.utm.my/1974/1/Yaacob1998_Voltage-currentCharacteristicsOfMetalOxide.pdf Yaacob, M.M. and Ghani, R.A. (1998) Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse. Electrical Insulation, 1998. Conference Record of the 1998 IEEE International Symposium on , 2 . pp. 460-463. |
spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Yaacob, M.M. Ghani, R.A. Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse |
title | Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse |
title_full | Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse |
title_fullStr | Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse |
title_full_unstemmed | Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse |
title_short | Voltage-current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse |
title_sort | voltage current characteristics of metal oxide varistors for low voltage telephone lightning protector under the application of multiple lightning impulse |
topic | TK Electrical engineering. Electronics Nuclear engineering |
url | http://eprints.utm.my/1974/1/Yaacob1998_Voltage-currentCharacteristicsOfMetalOxide.pdf |
work_keys_str_mv | AT yaacobmm voltagecurrentcharacteristicsofmetaloxidevaristorsforlowvoltagetelephonelightningprotectorundertheapplicationofmultiplelightningimpulse AT ghanira voltagecurrentcharacteristicsofmetaloxidevaristorsforlowvoltagetelephonelightningprotectorundertheapplicationofmultiplelightningimpulse |