Broken insulator effects on charge distribution measurement along suspension insulators

In the early years of power system network, porcelain and glass were used and still continuously serve the overhead lines to the present time. Obviously, they can provide distinction services over a long period of time. In spite of that, one or two of the insulators in the suspension may be damaged...

Full description

Bibliographic Details
Main Authors: Rosli, H., Othman, N. A., Piah, M. A. M., Jamail, N. A. M., Yousof, N. F. M., Ismail, M. N.
Format: Article
Published: Penerbit UTHM 2020
Subjects:
_version_ 1796856038244220928
author Rosli, H.
Othman, N. A.
Piah, M. A. M.
Jamail, N. A. M.
Yousof, N. F. M.
Ismail, M. N.
author_facet Rosli, H.
Othman, N. A.
Piah, M. A. M.
Jamail, N. A. M.
Yousof, N. F. M.
Ismail, M. N.
author_sort Rosli, H.
collection ePrints
description In the early years of power system network, porcelain and glass were used and still continuously serve the overhead lines to the present time. Obviously, they can provide distinction services over a long period of time. In spite of that, one or two of the insulators in the suspension may be damaged due to some cases yet the suspension insulator is believed can still be used for a certain amount of time. By studying some research from previous works, it is accepted that the different properties of porcelain and glass type had made these insulators vary in their respective capabilities to serve overhead lines. This paper endeavours the distribution of charge for the porcelain suspension insulator using chamber method. Finite element software particularly QuickfieldTM was used in simulation purpose to validate the experimental results. Similar patterns of charge distributions were acquired for both experimental and simulation works.
first_indexed 2024-03-05T18:37:30Z
format Article
id utm.eprints-24695
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T18:37:30Z
publishDate 2020
publisher Penerbit UTHM
record_format dspace
spelling utm.eprints-246952022-02-28T12:18:12Z http://eprints.utm.my/24695/ Broken insulator effects on charge distribution measurement along suspension insulators Rosli, H. Othman, N. A. Piah, M. A. M. Jamail, N. A. M. Yousof, N. F. M. Ismail, M. N. TK Electrical engineering. Electronics Nuclear engineering In the early years of power system network, porcelain and glass were used and still continuously serve the overhead lines to the present time. Obviously, they can provide distinction services over a long period of time. In spite of that, one or two of the insulators in the suspension may be damaged due to some cases yet the suspension insulator is believed can still be used for a certain amount of time. By studying some research from previous works, it is accepted that the different properties of porcelain and glass type had made these insulators vary in their respective capabilities to serve overhead lines. This paper endeavours the distribution of charge for the porcelain suspension insulator using chamber method. Finite element software particularly QuickfieldTM was used in simulation purpose to validate the experimental results. Similar patterns of charge distributions were acquired for both experimental and simulation works. Penerbit UTHM 2020 Article PeerReviewed Rosli, H. and Othman, N. A. and Piah, M. A. M. and Jamail, N. A. M. and Yousof, N. F. M. and Ismail, M. N. (2020) Broken insulator effects on charge distribution measurement along suspension insulators. International Journal of Integrated Engineering, 12 (2). pp. 97-105. ISSN 2229-838X http://dx.doi.org/10.30880/ijie.2020.12.02.012 DOI: 10.30880/ijie.2020.12.02.012
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Rosli, H.
Othman, N. A.
Piah, M. A. M.
Jamail, N. A. M.
Yousof, N. F. M.
Ismail, M. N.
Broken insulator effects on charge distribution measurement along suspension insulators
title Broken insulator effects on charge distribution measurement along suspension insulators
title_full Broken insulator effects on charge distribution measurement along suspension insulators
title_fullStr Broken insulator effects on charge distribution measurement along suspension insulators
title_full_unstemmed Broken insulator effects on charge distribution measurement along suspension insulators
title_short Broken insulator effects on charge distribution measurement along suspension insulators
title_sort broken insulator effects on charge distribution measurement along suspension insulators
topic TK Electrical engineering. Electronics Nuclear engineering
work_keys_str_mv AT roslih brokeninsulatoreffectsonchargedistributionmeasurementalongsuspensioninsulators
AT othmanna brokeninsulatoreffectsonchargedistributionmeasurementalongsuspensioninsulators
AT piahmam brokeninsulatoreffectsonchargedistributionmeasurementalongsuspensioninsulators
AT jamailnam brokeninsulatoreffectsonchargedistributionmeasurementalongsuspensioninsulators
AT yousofnfm brokeninsulatoreffectsonchargedistributionmeasurementalongsuspensioninsulators
AT ismailmn brokeninsulatoreffectsonchargedistributionmeasurementalongsuspensioninsulators