Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler

A directional fiber coupler with exertion loss 0.03 dB has been successfully fabricated using fusion technique with typical coupling ratio 1–90%. The coupling region of two twisted single mode fiber is heated by injecting hydrogen gas at 2.5 bar. During fusion process, both two sides of fibers are p...

Full description

Bibliographic Details
Main Authors: Irawan, Dedi, Saktioto, Saktioto, Ali, Jalil, Fadhali, Mohamed, Erwin, Erwin
Format: Article
Published: Wiley Periodicals 2012
Subjects:
_version_ 1796857201696964608
author Irawan, Dedi
Saktioto, Saktioto
Ali, Jalil
Fadhali, Mohamed
Erwin, Erwin
author_facet Irawan, Dedi
Saktioto, Saktioto
Ali, Jalil
Fadhali, Mohamed
Erwin, Erwin
author_sort Irawan, Dedi
collection ePrints
description A directional fiber coupler with exertion loss 0.03 dB has been successfully fabricated using fusion technique with typical coupling ratio 1–90%. The coupling region of two twisted single mode fiber is heated by injecting hydrogen gas at 2.5 bar. During fusion process, both two sides of fibers are pulled by stages that are automatically motorized in range of 800–4800 µm, and stopped when the desired coupling ratio is reached. The parameters of automated mechanical motion of pulling stages and coupling parameters at fusion region have been calculated by using kinetic model. The effect of heating and elongation reduces the diameter of cross section tapered region with a diameter 6.35 micrometer scale. As the fabrication of fiber couplers described by degree of fusion, which is function of heating and pulling length, it can be seen clearly that the coupling coefficient between the fibers increases exponentially with increasing the degree of fusion. However, by knowing coupling power and mechanical motion parameters, the fabrication of directional fiber coupler can be optimized.
first_indexed 2024-03-05T18:54:13Z
format Article
id utm.eprints-33526
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T18:54:13Z
publishDate 2012
publisher Wiley Periodicals
record_format dspace
spelling utm.eprints-335262018-11-30T06:37:29Z http://eprints.utm.my/33526/ Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler Irawan, Dedi Saktioto, Saktioto Ali, Jalil Fadhali, Mohamed Erwin, Erwin QC Physics A directional fiber coupler with exertion loss 0.03 dB has been successfully fabricated using fusion technique with typical coupling ratio 1–90%. The coupling region of two twisted single mode fiber is heated by injecting hydrogen gas at 2.5 bar. During fusion process, both two sides of fibers are pulled by stages that are automatically motorized in range of 800–4800 µm, and stopped when the desired coupling ratio is reached. The parameters of automated mechanical motion of pulling stages and coupling parameters at fusion region have been calculated by using kinetic model. The effect of heating and elongation reduces the diameter of cross section tapered region with a diameter 6.35 micrometer scale. As the fabrication of fiber couplers described by degree of fusion, which is function of heating and pulling length, it can be seen clearly that the coupling coefficient between the fibers increases exponentially with increasing the degree of fusion. However, by knowing coupling power and mechanical motion parameters, the fabrication of directional fiber coupler can be optimized. Wiley Periodicals 2012-08 Article PeerReviewed Irawan, Dedi and Saktioto, Saktioto and Ali, Jalil and Fadhali, Mohamed and Erwin, Erwin (2012) Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler. Microwave and Optical Technology Letters, 54 (8). pp. 1932-1935. ISSN 0895-2477 http://dx.doi.org/10.1002/mop.26937 DOI:10.1002/mop.26937
spellingShingle QC Physics
Irawan, Dedi
Saktioto, Saktioto
Ali, Jalil
Fadhali, Mohamed
Erwin, Erwin
Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler
title Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler
title_full Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler
title_fullStr Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler
title_full_unstemmed Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler
title_short Estimation of coupling parameters for auto-motorized fabrication of fused fiber coupler
title_sort estimation of coupling parameters for auto motorized fabrication of fused fiber coupler
topic QC Physics
work_keys_str_mv AT irawandedi estimationofcouplingparametersforautomotorizedfabricationoffusedfibercoupler
AT saktiotosaktioto estimationofcouplingparametersforautomotorizedfabricationoffusedfibercoupler
AT alijalil estimationofcouplingparametersforautomotorizedfabricationoffusedfibercoupler
AT fadhalimohamed estimationofcouplingparametersforautomotorizedfabricationoffusedfibercoupler
AT erwinerwin estimationofcouplingparametersforautomotorizedfabricationoffusedfibercoupler