Experimental tests on composite beam with various slab systems
This paper presents the structural behaviour of composite beams with various floor systems tested in full-scale arrangement. Six full-scale specimens with staggered and non-staggered arrangement of studs on the composite beams were tested until failure. The moment capacities obtained from the experi...