Liquid to particle heat transfer in fluidised beds

The liquid to particle heat transfer coefficient was measured in beds fluidized by water and three glycerol-water mixtures. A literature survey revealed little agreement between the results of previous investigators of fluid to particle heat transfer. A variety of techniques was employed to measure...

Full description

Bibliographic Details
Main Authors: Hassan, Onn, Stepanex, J.B.
Format: Article
Language:English
Published: 1989
Subjects:
Online Access:http://eprints.utm.my/4800/1/OnnHassan1989_LiquidToParticleHeatTransfer.pdf
_version_ 1796853797843107840
author Hassan, Onn
Stepanex, J.B.
author_facet Hassan, Onn
Stepanex, J.B.
author_sort Hassan, Onn
collection ePrints
description The liquid to particle heat transfer coefficient was measured in beds fluidized by water and three glycerol-water mixtures. A literature survey revealed little agreement between the results of previous investigators of fluid to particle heat transfer. A variety of techniques was employed to measure the fluid to particle heat transfer coefficient, also, temperature data were recorded and interpreted in many ways. In this investigation, the liquid to particle heat transfer coefficients were measured under unsteady state conditions by introducing a step change in the temperature of the inflowing liquid to beds of aluminium and alumina particles fluidised by water or three glycerol-water mixtures. The coefficients were measured by employing the technique of tagging a particle with a thermocouple which allows a direct measurement of particle temperature.
first_indexed 2024-03-05T18:04:54Z
format Article
id utm.eprints-4800
institution Universiti Teknologi Malaysia - ePrints
language English
last_indexed 2024-03-05T18:04:54Z
publishDate 1989
record_format dspace
spelling utm.eprints-48002010-06-01T03:20:51Z http://eprints.utm.my/4800/ Liquid to particle heat transfer in fluidised beds Hassan, Onn Stepanex, J.B. T Technology (General) The liquid to particle heat transfer coefficient was measured in beds fluidized by water and three glycerol-water mixtures. A literature survey revealed little agreement between the results of previous investigators of fluid to particle heat transfer. A variety of techniques was employed to measure the fluid to particle heat transfer coefficient, also, temperature data were recorded and interpreted in many ways. In this investigation, the liquid to particle heat transfer coefficients were measured under unsteady state conditions by introducing a step change in the temperature of the inflowing liquid to beds of aluminium and alumina particles fluidised by water or three glycerol-water mixtures. The coefficients were measured by employing the technique of tagging a particle with a thermocouple which allows a direct measurement of particle temperature. 1989 Article PeerReviewed application/pdf en http://eprints.utm.my/4800/1/OnnHassan1989_LiquidToParticleHeatTransfer.pdf Hassan, Onn and Stepanex, J.B. (1989) Liquid to particle heat transfer in fluidised beds. Proceedings of The Fifth Symposium Of Malaysian Chemical Engineers . pp. 24-40.
spellingShingle T Technology (General)
Hassan, Onn
Stepanex, J.B.
Liquid to particle heat transfer in fluidised beds
title Liquid to particle heat transfer in fluidised beds
title_full Liquid to particle heat transfer in fluidised beds
title_fullStr Liquid to particle heat transfer in fluidised beds
title_full_unstemmed Liquid to particle heat transfer in fluidised beds
title_short Liquid to particle heat transfer in fluidised beds
title_sort liquid to particle heat transfer in fluidised beds
topic T Technology (General)
url http://eprints.utm.my/4800/1/OnnHassan1989_LiquidToParticleHeatTransfer.pdf
work_keys_str_mv AT hassanonn liquidtoparticleheattransferinfluidisedbeds
AT stepanexjb liquidtoparticleheattransferinfluidisedbeds