Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits

Present investigation aims to establish the dosimetric characteristics of a novel fabricated flat fibre TLD system for postal radiotherapy dose audits. Various thermoluminescence (TL) properties have been investigated for five sizes of 6 mol% Ge-doped optical fibres. Key dosimetric characteristics i...

Full description

Bibliographic Details
Main Authors: Ahmad Fadzil, Muhammad Safwan, Ramli, N. N. H., Jusoh, M. A., Kadni, Taiman, Bradley, David Andrew, Ung, Ngie Min, Hashim, Suhairul, Mohd. Noor, Noramaliza
Format: Article
Language:English
Published: Institute of Physics Publishing 2014
Subjects:
Online Access:http://eprints.utm.my/52426/1/SuhairulHashim2014_Dosimetriccharacteristicsoffabricated.pdf
_version_ 1796859741579771904
author Ahmad Fadzil, Muhammad Safwan
Ramli, N. N. H.
Jusoh, M. A.
Kadni, Taiman
Bradley, David Andrew
Ung, Ngie Min
Hashim, Suhairul
Mohd. Noor, Noramaliza
author_facet Ahmad Fadzil, Muhammad Safwan
Ramli, N. N. H.
Jusoh, M. A.
Kadni, Taiman
Bradley, David Andrew
Ung, Ngie Min
Hashim, Suhairul
Mohd. Noor, Noramaliza
author_sort Ahmad Fadzil, Muhammad Safwan
collection ePrints
description Present investigation aims to establish the dosimetric characteristics of a novel fabricated flat fibre TLD system for postal radiotherapy dose audits. Various thermoluminescence (TL) properties have been investigated for five sizes of 6 mol% Ge-doped optical fibres. Key dosimetric characteristics including reproducibility, linearity, fading and energy dependence have been established. Irradiations were carried out using a linear accelerator (linac) and a Cobalt-60 machine. For doses from 0.5 Gy up to 10 Gy, Ge-doped flat fibres exhibit linearity between TL yield and dose, reproducible to better than 8% standard deviation (SD) following repeat measurements (n = 3). For photons generated at potentials from 1.25 MeV to 10 MV an energy-dependent response is noted, with a coefficient of variation (CV) of less than 40% over the range of energies investigated. For 6.0 mm length flat fibres 100 μm thick × 350 pm wide, the TL fading loss following 30 days of storage at room temperature was < 8%. The Ge-doped flat fibre system represents a viable basis for use in postal radiotherapy dose audits, corrections being made for the various factors influencing the TL yield
first_indexed 2024-03-05T19:31:43Z
format Article
id utm.eprints-52426
institution Universiti Teknologi Malaysia - ePrints
language English
last_indexed 2024-03-05T19:31:43Z
publishDate 2014
publisher Institute of Physics Publishing
record_format dspace
spelling utm.eprints-524262018-09-17T04:08:20Z http://eprints.utm.my/52426/ Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits Ahmad Fadzil, Muhammad Safwan Ramli, N. N. H. Jusoh, M. A. Kadni, Taiman Bradley, David Andrew Ung, Ngie Min Hashim, Suhairul Mohd. Noor, Noramaliza Q Science Present investigation aims to establish the dosimetric characteristics of a novel fabricated flat fibre TLD system for postal radiotherapy dose audits. Various thermoluminescence (TL) properties have been investigated for five sizes of 6 mol% Ge-doped optical fibres. Key dosimetric characteristics including reproducibility, linearity, fading and energy dependence have been established. Irradiations were carried out using a linear accelerator (linac) and a Cobalt-60 machine. For doses from 0.5 Gy up to 10 Gy, Ge-doped flat fibres exhibit linearity between TL yield and dose, reproducible to better than 8% standard deviation (SD) following repeat measurements (n = 3). For photons generated at potentials from 1.25 MeV to 10 MV an energy-dependent response is noted, with a coefficient of variation (CV) of less than 40% over the range of energies investigated. For 6.0 mm length flat fibres 100 μm thick × 350 pm wide, the TL fading loss following 30 days of storage at room temperature was < 8%. The Ge-doped flat fibre system represents a viable basis for use in postal radiotherapy dose audits, corrections being made for the various factors influencing the TL yield Institute of Physics Publishing 2014 Article PeerReviewed application/pdf en http://eprints.utm.my/52426/1/SuhairulHashim2014_Dosimetriccharacteristicsoffabricated.pdf Ahmad Fadzil, Muhammad Safwan and Ramli, N. N. H. and Jusoh, M. A. and Kadni, Taiman and Bradley, David Andrew and Ung, Ngie Min and Hashim, Suhairul and Mohd. Noor, Noramaliza (2014) Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits. Journal of Physics: Conference Series, 546 (1). ISSN 1742-6588 http://dx.doi.org/10.1088/1742-6596/546/1/012010 DOI: 10.1088/1742-6596/546/1/012010
spellingShingle Q Science
Ahmad Fadzil, Muhammad Safwan
Ramli, N. N. H.
Jusoh, M. A.
Kadni, Taiman
Bradley, David Andrew
Ung, Ngie Min
Hashim, Suhairul
Mohd. Noor, Noramaliza
Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
title Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
title_full Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
title_fullStr Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
title_full_unstemmed Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
title_short Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
title_sort dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
topic Q Science
url http://eprints.utm.my/52426/1/SuhairulHashim2014_Dosimetriccharacteristicsoffabricated.pdf
work_keys_str_mv AT ahmadfadzilmuhammadsafwan dosimetriccharacteristicsoffabricatedsilicafibreforpostalradiotherapydoseaudits
AT ramlinnh dosimetriccharacteristicsoffabricatedsilicafibreforpostalradiotherapydoseaudits
AT jusohma dosimetriccharacteristicsoffabricatedsilicafibreforpostalradiotherapydoseaudits
AT kadnitaiman dosimetriccharacteristicsoffabricatedsilicafibreforpostalradiotherapydoseaudits
AT bradleydavidandrew dosimetriccharacteristicsoffabricatedsilicafibreforpostalradiotherapydoseaudits
AT ungngiemin dosimetriccharacteristicsoffabricatedsilicafibreforpostalradiotherapydoseaudits
AT hashimsuhairul dosimetriccharacteristicsoffabricatedsilicafibreforpostalradiotherapydoseaudits
AT mohdnoornoramaliza dosimetriccharacteristicsoffabricatedsilicafibreforpostalradiotherapydoseaudits