Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review

Single cell mass (SCM) is one of the intrinsic properties of cell and is a vital part of single cell analysis (SCA). To date, a myriad numbers of works has been successfully reported for single cell mass measurement but the reported information are scattered, consequently a comprehensive review beco...

Full description

Bibliographic Details
Main Authors: Rahman, Md. Habibur A., Ahmad, Mohd. Ridzuan
Format: Article
Language:English
Published: Penerbit UTM 2014
Subjects:
Online Access:http://eprints.utm.my/53291/1/Md.HabiburRahman2014_Lab-on-chipmicrofluidicssystem.pdf
_version_ 1796859824086974464
author Rahman, Md. Habibur A.
Ahmad, Mohd. Ridzuan
author_facet Rahman, Md. Habibur A.
Ahmad, Mohd. Ridzuan
author_sort Rahman, Md. Habibur A.
collection ePrints
description Single cell mass (SCM) is one of the intrinsic properties of cell and is a vital part of single cell analysis (SCA). To date, a myriad numbers of works has been successfully reported for single cell mass measurement but the reported information are scattered, consequently a comprehensive review becomes mandatory to bring them together. Lab-on-chip microfluidics system integrated with micro-resonator provided an excellent platform to measure single cell mass directly (in presence of cells). On-chip microfluidics system like suspended micro channel resonator (SMR) was reported for non-adherent single yeast cell mass while 'living cantilever arrays' (LCA) was proposed to measure adherent HeLa cell mass. On the other hand, cantilever based resonant mass measurement system has non-uniform mass sensitivity; this issue has been overcome by pedestal mass measurement system (PMMS). PMMS has a unique geometrical structure that provided uniform mass sensitivity to the sensing surface. Moreover, we presented a comprehensive discussion of each of the available methods of SCM elaborating the sensing mechanism, geometry of the sensor and governing equations. It is hoped that, information presented in this comprehensive review paper will be a valuable source for the single cell mass analysers and biological researchers
first_indexed 2024-03-05T19:32:56Z
format Article
id utm.eprints-53291
institution Universiti Teknologi Malaysia - ePrints
language English
last_indexed 2024-03-05T19:32:56Z
publishDate 2014
publisher Penerbit UTM
record_format dspace
spelling utm.eprints-532912018-07-25T07:55:24Z http://eprints.utm.my/53291/ Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review Rahman, Md. Habibur A. Ahmad, Mohd. Ridzuan TK Electrical engineering. Electronics Nuclear engineering Single cell mass (SCM) is one of the intrinsic properties of cell and is a vital part of single cell analysis (SCA). To date, a myriad numbers of works has been successfully reported for single cell mass measurement but the reported information are scattered, consequently a comprehensive review becomes mandatory to bring them together. Lab-on-chip microfluidics system integrated with micro-resonator provided an excellent platform to measure single cell mass directly (in presence of cells). On-chip microfluidics system like suspended micro channel resonator (SMR) was reported for non-adherent single yeast cell mass while 'living cantilever arrays' (LCA) was proposed to measure adherent HeLa cell mass. On the other hand, cantilever based resonant mass measurement system has non-uniform mass sensitivity; this issue has been overcome by pedestal mass measurement system (PMMS). PMMS has a unique geometrical structure that provided uniform mass sensitivity to the sensing surface. Moreover, we presented a comprehensive discussion of each of the available methods of SCM elaborating the sensing mechanism, geometry of the sensor and governing equations. It is hoped that, information presented in this comprehensive review paper will be a valuable source for the single cell mass analysers and biological researchers Penerbit UTM 2014 Article PeerReviewed application/pdf en http://eprints.utm.my/53291/1/Md.HabiburRahman2014_Lab-on-chipmicrofluidicssystem.pdf Rahman, Md. Habibur A. and Ahmad, Mohd. Ridzuan (2014) Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review. Jurnal Teknologi (Sciences and Engineering), 69 (8). pp. 85-93. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v69.3301 DOI: 10.11113/jt.v69.3301
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Rahman, Md. Habibur A.
Ahmad, Mohd. Ridzuan
Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review
title Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review
title_full Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review
title_fullStr Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review
title_full_unstemmed Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review
title_short Lab-on-chip microfluidics system for single cell mass measurement: a comprehensive review
title_sort lab on chip microfluidics system for single cell mass measurement a comprehensive review
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/53291/1/Md.HabiburRahman2014_Lab-on-chipmicrofluidicssystem.pdf
work_keys_str_mv AT rahmanmdhabibura labonchipmicrofluidicssystemforsinglecellmassmeasurementacomprehensivereview
AT ahmadmohdridzuan labonchipmicrofluidicssystemforsinglecellmassmeasurementacomprehensivereview