The effect of cannulated screw placement angle in the management of femoral neck fracture

Fixation with cannulated screw was widely accepted for management of femoral neck fracture. However, the angle of placement cannulated screw for management of femoral neck fracture still controversial. The present study aims to investigate the mechanical behavior of the cannulated screws with two di...

Full description

Bibliographic Details
Main Authors: Ishak, Muhammad Farhan, Abdul Kadir, Mohammed Rafiq, Harun, Habibollah, Abdul Rahman, Shaifuzain
Format: Conference or Workshop Item
Published: 2013
Subjects:
_version_ 1796861349629788160
author Ishak, Muhammad Farhan
Abdul Kadir, Mohammed Rafiq
Harun, Habibollah
Abdul Rahman, Shaifuzain
author_facet Ishak, Muhammad Farhan
Abdul Kadir, Mohammed Rafiq
Harun, Habibollah
Abdul Rahman, Shaifuzain
author_sort Ishak, Muhammad Farhan
collection ePrints
description Fixation with cannulated screw was widely accepted for management of femoral neck fracture. However, the angle of placement cannulated screw for management of femoral neck fracture still controversial. The present study aims to investigate the mechanical behavior of the cannulated screws with two different angles of placements which are 135o and 150o in inverted triangular configuration for management of femoral neck fracture via finite element method. Therefore, the 3D model of a proximal femur consist of femoral neck fracture was constructed from CT data images using medical image processing software. The von Mises stress distributions on the cannulated screws were compared between each screw angle placement. The result showed that the cannulated screws in inverted triangle with 135o of placement angle have better stress distributions than 150o placement angle.
first_indexed 2024-03-05T19:54:59Z
format Conference or Workshop Item
id utm.eprints-62854
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T19:54:59Z
publishDate 2013
record_format dspace
spelling utm.eprints-628542017-09-06T03:39:24Z http://eprints.utm.my/62854/ The effect of cannulated screw placement angle in the management of femoral neck fracture Ishak, Muhammad Farhan Abdul Kadir, Mohammed Rafiq Harun, Habibollah Abdul Rahman, Shaifuzain R Medicine (General) Fixation with cannulated screw was widely accepted for management of femoral neck fracture. However, the angle of placement cannulated screw for management of femoral neck fracture still controversial. The present study aims to investigate the mechanical behavior of the cannulated screws with two different angles of placements which are 135o and 150o in inverted triangular configuration for management of femoral neck fracture via finite element method. Therefore, the 3D model of a proximal femur consist of femoral neck fracture was constructed from CT data images using medical image processing software. The von Mises stress distributions on the cannulated screws were compared between each screw angle placement. The result showed that the cannulated screws in inverted triangle with 135o of placement angle have better stress distributions than 150o placement angle. 2013 Conference or Workshop Item PeerReviewed Ishak, Muhammad Farhan and Abdul Kadir, Mohammed Rafiq and Harun, Habibollah and Abdul Rahman, Shaifuzain (2013) The effect of cannulated screw placement angle in the management of femoral neck fracture. In: 1st International Materials, Industrial, and Manufacturing Engineering Conference, MIMEC 2013, 4-6 Dec, 2013, Johor Bahru, Malaysia. http://dx.doi.org/10.4028/www.scientific.net/AMR.845.216
spellingShingle R Medicine (General)
Ishak, Muhammad Farhan
Abdul Kadir, Mohammed Rafiq
Harun, Habibollah
Abdul Rahman, Shaifuzain
The effect of cannulated screw placement angle in the management of femoral neck fracture
title The effect of cannulated screw placement angle in the management of femoral neck fracture
title_full The effect of cannulated screw placement angle in the management of femoral neck fracture
title_fullStr The effect of cannulated screw placement angle in the management of femoral neck fracture
title_full_unstemmed The effect of cannulated screw placement angle in the management of femoral neck fracture
title_short The effect of cannulated screw placement angle in the management of femoral neck fracture
title_sort effect of cannulated screw placement angle in the management of femoral neck fracture
topic R Medicine (General)
work_keys_str_mv AT ishakmuhammadfarhan theeffectofcannulatedscrewplacementangleinthemanagementoffemoralneckfracture
AT abdulkadirmohammedrafiq theeffectofcannulatedscrewplacementangleinthemanagementoffemoralneckfracture
AT harunhabibollah theeffectofcannulatedscrewplacementangleinthemanagementoffemoralneckfracture
AT abdulrahmanshaifuzain theeffectofcannulatedscrewplacementangleinthemanagementoffemoralneckfracture
AT ishakmuhammadfarhan effectofcannulatedscrewplacementangleinthemanagementoffemoralneckfracture
AT abdulkadirmohammedrafiq effectofcannulatedscrewplacementangleinthemanagementoffemoralneckfracture
AT harunhabibollah effectofcannulatedscrewplacementangleinthemanagementoffemoralneckfracture
AT abdulrahmanshaifuzain effectofcannulatedscrewplacementangleinthemanagementoffemoralneckfracture