Investigation into low energy beta imaging using CCD imaging sensor

Autoradiography is an extensively used technique to create a record of the radioactivity dispersion throughout the biological samples. Conventionally, this technique was performed using film. Spatial resolution and sensitivity are the main parameters of interest in developing new digital autoradiogr...

Full description

Bibliographic Details
Main Author: Hashim, Suhairul
Format: Thesis
Language:English
Published: 2004
Subjects:
Online Access:http://eprints.utm.my/6840/1/SuhairulHashimMFS2004.pdf
_version_ 1825909959617937408
author Hashim, Suhairul
author_facet Hashim, Suhairul
author_sort Hashim, Suhairul
collection ePrints
description Autoradiography is an extensively used technique to create a record of the radioactivity dispersion throughout the biological samples. Conventionally, this technique was performed using film. Spatial resolution and sensitivity are the main parameters of interest in developing new digital autoradiography systems. In conventional autoradiography, the images that have been documented display an excellent spatial resolution but at the same time show lack of sensitivity, very limited dynamic range and non-linear response. To overcome the disadvantages of this method, digital autoradiography systems have been developed to address the major drawbacks of the former technique.
first_indexed 2024-03-05T18:09:55Z
format Thesis
id utm.eprints-6840
institution Universiti Teknologi Malaysia - ePrints
language English
last_indexed 2024-03-05T18:09:55Z
publishDate 2004
record_format dspace
spelling utm.eprints-68402018-09-19T05:07:06Z http://eprints.utm.my/6840/ Investigation into low energy beta imaging using CCD imaging sensor Hashim, Suhairul QC Physics Autoradiography is an extensively used technique to create a record of the radioactivity dispersion throughout the biological samples. Conventionally, this technique was performed using film. Spatial resolution and sensitivity are the main parameters of interest in developing new digital autoradiography systems. In conventional autoradiography, the images that have been documented display an excellent spatial resolution but at the same time show lack of sensitivity, very limited dynamic range and non-linear response. To overcome the disadvantages of this method, digital autoradiography systems have been developed to address the major drawbacks of the former technique. 2004-09 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/6840/1/SuhairulHashimMFS2004.pdf Hashim, Suhairul (2004) Investigation into low energy beta imaging using CCD imaging sensor. Masters thesis, University of Surrey, United Kingdom, School of Electronics and Physical Sciences. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62447
spellingShingle QC Physics
Hashim, Suhairul
Investigation into low energy beta imaging using CCD imaging sensor
title Investigation into low energy beta imaging using CCD imaging sensor
title_full Investigation into low energy beta imaging using CCD imaging sensor
title_fullStr Investigation into low energy beta imaging using CCD imaging sensor
title_full_unstemmed Investigation into low energy beta imaging using CCD imaging sensor
title_short Investigation into low energy beta imaging using CCD imaging sensor
title_sort investigation into low energy beta imaging using ccd imaging sensor
topic QC Physics
url http://eprints.utm.my/6840/1/SuhairulHashimMFS2004.pdf
work_keys_str_mv AT hashimsuhairul investigationintolowenergybetaimagingusingccdimagingsensor