Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method

In practice, a standard energy meter can only capture the overall electricity consumption and estimating electricity consumption pattern of various appliances from the overall consumption pattern is complicated. Therefore, the Non-Intrusive Appliance Load Monitoring (NIALM) technique can be applied...

Full description

Bibliographic Details
Main Authors: Asa @ Esa, Nur Farahin, Abdullah, Md. Pauzi, Hassan, Mohammad Yusri, Hussin, Faridah
Format: Article
Language:English
Published: Penerbit UTM Press 2016
Subjects:
Online Access:http://eprints.utm.my/69349/1/MohammadYusriHassan2016_Electricityconsumptionpatterndisaggregationusing.pdf
_version_ 1796861685106999296
author Asa @ Esa, Nur Farahin
Abdullah, Md. Pauzi
Hassan, Mohammad Yusri
Hussin, Faridah
author_facet Asa @ Esa, Nur Farahin
Abdullah, Md. Pauzi
Hassan, Mohammad Yusri
Hussin, Faridah
author_sort Asa @ Esa, Nur Farahin
collection ePrints
description In practice, a standard energy meter can only capture the overall electricity consumption and estimating electricity consumption pattern of various appliances from the overall consumption pattern is complicated. Therefore, the Non-Intrusive Appliance Load Monitoring (NIALM) technique can be applied to trace electricity consumption from each appliance in a monitored building. However, the method requires a detailed, second-by-second power consumption data which is commonly not available without the use of high specification energy meter. Hence, this paper analyzes the impact of different time sampling data in estimating the energy consumption pattern of various appliances through NIALM method. This is so that consumers will have an overview of time sampling data which is required in order to apply the NIALM technique. As for the analysis, air-conditioning systems and fluorescent lamps were used in the experimental setup. One minute sample rate was the minimum time interval required by NIALM carried out in this analysis. Through the study presented in this paper, it can be established that higher time sampling led to uncertain appliance detection and low accuracy.
first_indexed 2024-03-05T20:00:09Z
format Article
id utm.eprints-69349
institution Universiti Teknologi Malaysia - ePrints
language English
last_indexed 2024-03-05T20:00:09Z
publishDate 2016
publisher Penerbit UTM Press
record_format dspace
spelling utm.eprints-693492017-11-22T00:45:09Z http://eprints.utm.my/69349/ Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method Asa @ Esa, Nur Farahin Abdullah, Md. Pauzi Hassan, Mohammad Yusri Hussin, Faridah TK Electrical engineering. Electronics Nuclear engineering In practice, a standard energy meter can only capture the overall electricity consumption and estimating electricity consumption pattern of various appliances from the overall consumption pattern is complicated. Therefore, the Non-Intrusive Appliance Load Monitoring (NIALM) technique can be applied to trace electricity consumption from each appliance in a monitored building. However, the method requires a detailed, second-by-second power consumption data which is commonly not available without the use of high specification energy meter. Hence, this paper analyzes the impact of different time sampling data in estimating the energy consumption pattern of various appliances through NIALM method. This is so that consumers will have an overview of time sampling data which is required in order to apply the NIALM technique. As for the analysis, air-conditioning systems and fluorescent lamps were used in the experimental setup. One minute sample rate was the minimum time interval required by NIALM carried out in this analysis. Through the study presented in this paper, it can be established that higher time sampling led to uncertain appliance detection and low accuracy. Penerbit UTM Press 2016 Article PeerReviewed application/pdf en http://eprints.utm.my/69349/1/MohammadYusriHassan2016_Electricityconsumptionpatterndisaggregationusing.pdf Asa @ Esa, Nur Farahin and Abdullah, Md. Pauzi and Hassan, Mohammad Yusri and Hussin, Faridah (2016) Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method. Jurnal Teknologi, 78 (5-7). pp. 29-35. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v78.8692 DOI:10.11113/jt.v78.8692
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Asa @ Esa, Nur Farahin
Abdullah, Md. Pauzi
Hassan, Mohammad Yusri
Hussin, Faridah
Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method
title Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method
title_full Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method
title_fullStr Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method
title_full_unstemmed Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method
title_short Electricity consumption pattern disaggregation using non-intrusive appliance load monitoring method
title_sort electricity consumption pattern disaggregation using non intrusive appliance load monitoring method
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/69349/1/MohammadYusriHassan2016_Electricityconsumptionpatterndisaggregationusing.pdf
work_keys_str_mv AT asaesanurfarahin electricityconsumptionpatterndisaggregationusingnonintrusiveapplianceloadmonitoringmethod
AT abdullahmdpauzi electricityconsumptionpatterndisaggregationusingnonintrusiveapplianceloadmonitoringmethod
AT hassanmohammadyusri electricityconsumptionpatterndisaggregationusingnonintrusiveapplianceloadmonitoringmethod
AT hussinfaridah electricityconsumptionpatterndisaggregationusingnonintrusiveapplianceloadmonitoringmethod