Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering

Ti-Ni and Ti-Ni-Ag shape memory alloys (SMAs) were prepared by microwave sintering. In Ti (49 -%Ag)-Ni51-Ag (atomic percentage), the silver was added with three percentages of (0.246, 0.5 and 1.51) at. %, respectively. The influence of Ag addition on the microstructure, phase composition, transforma...

Full description

Bibliographic Details
Main Authors: Ibrahim, M. K., Hamzah, E., Saud, S. N., Nazim, E. M., Bahador, A.
Format: Article
Language:English
Published: Penerbit UTM Press 2018
Subjects:
Online Access:http://eprints.utm.my/79705/1/EHamzah2018_SilverAdditionsInfluenceonBiomedicalPorous.pdf
_version_ 1796863093796503552
author Ibrahim, M. K.
Hamzah, E.
Saud, S. N.
Nazim, E. M.
Bahador, A.
author_facet Ibrahim, M. K.
Hamzah, E.
Saud, S. N.
Nazim, E. M.
Bahador, A.
author_sort Ibrahim, M. K.
collection ePrints
description Ti-Ni and Ti-Ni-Ag shape memory alloys (SMAs) were prepared by microwave sintering. In Ti (49 -%Ag)-Ni51-Ag (atomic percentage), the silver was added with three percentages of (0.246, 0.5 and 1.51) at. %, respectively. The influence of Ag addition on the microstructure, phase composition, transformation temperatures and mechanical properties were investigated by scanning electron microscopy (SEM), X-ray diffraction (XRD), differential scanning calorimeter (DSC) and compression test. The microstructure shows needles and plates inside Ti-rich region. The R phase appears at the plane (-112) and the plane (300). This phase has appeared during cooling and heating of the baseline of DSC test. The compression strain at maximum strength was improved, while the compression strength was reduced. The highest compressive strain was for the sample with 0.246 at. % Ag. The elastic modulus decreases with the increasing of Ag content. The elastic modulus of these alloys was low that make it proper for biomedical applications such as natural human bone due to the sintering method and also improve by adding silver.
first_indexed 2024-03-05T20:21:32Z
format Article
id utm.eprints-79705
institution Universiti Teknologi Malaysia - ePrints
language English
last_indexed 2024-03-05T20:21:32Z
publishDate 2018
publisher Penerbit UTM Press
record_format dspace
spelling utm.eprints-797052019-01-28T06:38:16Z http://eprints.utm.my/79705/ Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering Ibrahim, M. K. Hamzah, E. Saud, S. N. Nazim, E. M. Bahador, A. TJ Mechanical engineering and machinery Ti-Ni and Ti-Ni-Ag shape memory alloys (SMAs) were prepared by microwave sintering. In Ti (49 -%Ag)-Ni51-Ag (atomic percentage), the silver was added with three percentages of (0.246, 0.5 and 1.51) at. %, respectively. The influence of Ag addition on the microstructure, phase composition, transformation temperatures and mechanical properties were investigated by scanning electron microscopy (SEM), X-ray diffraction (XRD), differential scanning calorimeter (DSC) and compression test. The microstructure shows needles and plates inside Ti-rich region. The R phase appears at the plane (-112) and the plane (300). This phase has appeared during cooling and heating of the baseline of DSC test. The compression strain at maximum strength was improved, while the compression strength was reduced. The highest compressive strain was for the sample with 0.246 at. % Ag. The elastic modulus decreases with the increasing of Ag content. The elastic modulus of these alloys was low that make it proper for biomedical applications such as natural human bone due to the sintering method and also improve by adding silver. Penerbit UTM Press 2018 Article PeerReviewed application/pdf en http://eprints.utm.my/79705/1/EHamzah2018_SilverAdditionsInfluenceonBiomedicalPorous.pdf Ibrahim, M. K. and Hamzah, E. and Saud, S. N. and Nazim, E. M. and Bahador, A. (2018) Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering. Jurnal Teknologi, 80 (4). pp. 97-102. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v80.11766 DOI:10.11113/jt.v80.11766
spellingShingle TJ Mechanical engineering and machinery
Ibrahim, M. K.
Hamzah, E.
Saud, S. N.
Nazim, E. M.
Bahador, A.
Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering
title Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering
title_full Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering
title_fullStr Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering
title_full_unstemmed Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering
title_short Silver additions influence on biomedical porous Ti-Ni SMAs fabricated by microwave sintering
title_sort silver additions influence on biomedical porous ti ni smas fabricated by microwave sintering
topic TJ Mechanical engineering and machinery
url http://eprints.utm.my/79705/1/EHamzah2018_SilverAdditionsInfluenceonBiomedicalPorous.pdf
work_keys_str_mv AT ibrahimmk silveradditionsinfluenceonbiomedicalporoustinismasfabricatedbymicrowavesintering
AT hamzahe silveradditionsinfluenceonbiomedicalporoustinismasfabricatedbymicrowavesintering
AT saudsn silveradditionsinfluenceonbiomedicalporoustinismasfabricatedbymicrowavesintering
AT nazimem silveradditionsinfluenceonbiomedicalporoustinismasfabricatedbymicrowavesintering
AT bahadora silveradditionsinfluenceonbiomedicalporoustinismasfabricatedbymicrowavesintering