Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering

Introduction: Currently, the design of extracellular matrix (ECM) with nanoscale properties in bone tissue engineering is challenging. For bone tissue engineering, the ECM must have certain properties such as being nontoxic, highly porous, and should not cause foreign body reactions. Materials and m...

Full description

Bibliographic Details
Main Authors: Qi, J., Zhang, H., Wang, Y., Mani, M. P., Jaganathan, S. K.
Format: Article
Published: Dove Medical Press Ltd. 2018
Subjects:
_version_ 1796863101367222272
author Qi, J.
Zhang, H.
Wang, Y.
Mani, M. P.
Jaganathan, S. K.
author_facet Qi, J.
Zhang, H.
Wang, Y.
Mani, M. P.
Jaganathan, S. K.
author_sort Qi, J.
collection ePrints
description Introduction: Currently, the design of extracellular matrix (ECM) with nanoscale properties in bone tissue engineering is challenging. For bone tissue engineering, the ECM must have certain properties such as being nontoxic, highly porous, and should not cause foreign body reactions. Materials and methods: In this study, the hybrid scaffold based on polyvinyl alcohol (PVA) blended with metallocene polyethylene (mPE) and plectranthus amboinicus (PA) was fabricated for bone tissue engineering via electrospinning. The fabricated hybrid nanocomposites were characterized by scanning electron microscopy (SEM), Fourier transform and infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), contact angle measurement, and atomic force microscopy (AFM). Furthermore, activated partial thromboplastin time (APTT), prothrombin time (PT), and hemolytic assays were used to investigate the blood compatibility of the prepared hybrid nanocomposites. Results: The prepared hybrid nanocomposites showed reduced fiber diameter (238±45 nm) and also increased porosity (87%) with decreased pore diameter (340±86 nm) compared with pure PVA. The interactions between PVA, mPE, and PA were identified by the formation of the additional peaks as revealed in FTIR. Furthermore, the prepared hybrid nanocomposites showed a decreased contact angle of 51°±1.32° indicating a hydrophilic nature and exhibited lower thermal stability compared to pristine PVA. Moreover, the mechanical results revealed that the electrospun scaffold showed an improved tensile strength of 3.55±0.29 MPa compared with the pristine PVA (1.8±0.52 MPa). The prepared hybrid nanocomposites showed delayed blood clotting as noted in APTT and PT assays indicating better blood compatibility. Moreover, the hemolysis assay revealed that the hybrid nanocomposites exhibited a low hemolytic index of 0.6% compared with pure PVA, which was 1.6% suggesting the safety of the developed nanocomposite to red blood cells (RBCs). Conclusion: The prepared nanocomposites exhibited better physico-chemical properties, sufficient porosity, mechanical strength, and blood compatibility, which favors it as a valuable candidate in bone tissue engineering for repairing the bone defects.
first_indexed 2024-03-05T20:21:39Z
format Article
id utm.eprints-79745
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T20:21:39Z
publishDate 2018
publisher Dove Medical Press Ltd.
record_format dspace
spelling utm.eprints-797452019-01-28T06:50:05Z http://eprints.utm.my/79745/ Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering Qi, J. Zhang, H. Wang, Y. Mani, M. P. Jaganathan, S. K. QH301 Biology Introduction: Currently, the design of extracellular matrix (ECM) with nanoscale properties in bone tissue engineering is challenging. For bone tissue engineering, the ECM must have certain properties such as being nontoxic, highly porous, and should not cause foreign body reactions. Materials and methods: In this study, the hybrid scaffold based on polyvinyl alcohol (PVA) blended with metallocene polyethylene (mPE) and plectranthus amboinicus (PA) was fabricated for bone tissue engineering via electrospinning. The fabricated hybrid nanocomposites were characterized by scanning electron microscopy (SEM), Fourier transform and infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), contact angle measurement, and atomic force microscopy (AFM). Furthermore, activated partial thromboplastin time (APTT), prothrombin time (PT), and hemolytic assays were used to investigate the blood compatibility of the prepared hybrid nanocomposites. Results: The prepared hybrid nanocomposites showed reduced fiber diameter (238±45 nm) and also increased porosity (87%) with decreased pore diameter (340±86 nm) compared with pure PVA. The interactions between PVA, mPE, and PA were identified by the formation of the additional peaks as revealed in FTIR. Furthermore, the prepared hybrid nanocomposites showed a decreased contact angle of 51°±1.32° indicating a hydrophilic nature and exhibited lower thermal stability compared to pristine PVA. Moreover, the mechanical results revealed that the electrospun scaffold showed an improved tensile strength of 3.55±0.29 MPa compared with the pristine PVA (1.8±0.52 MPa). The prepared hybrid nanocomposites showed delayed blood clotting as noted in APTT and PT assays indicating better blood compatibility. Moreover, the hemolysis assay revealed that the hybrid nanocomposites exhibited a low hemolytic index of 0.6% compared with pure PVA, which was 1.6% suggesting the safety of the developed nanocomposite to red blood cells (RBCs). Conclusion: The prepared nanocomposites exhibited better physico-chemical properties, sufficient porosity, mechanical strength, and blood compatibility, which favors it as a valuable candidate in bone tissue engineering for repairing the bone defects. Dove Medical Press Ltd. 2018 Article PeerReviewed Qi, J. and Zhang, H. and Wang, Y. and Mani, M. P. and Jaganathan, S. K. (2018) Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering. International Journal of Nanomedicine, 13 . pp. 2777-2788. ISSN 1176-9114 http://dx.doi.org/10.2147/IJN.S151242 DOI:10.2147/IJN.S151242
spellingShingle QH301 Biology
Qi, J.
Zhang, H.
Wang, Y.
Mani, M. P.
Jaganathan, S. K.
Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_full Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_fullStr Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_full_unstemmed Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_short Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_sort development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus pva mpe pa for bone tissue engineering
topic QH301 Biology
work_keys_str_mv AT qij developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering
AT zhangh developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering
AT wangy developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering
AT manimp developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering
AT jaganathansk developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering