Experimental investigation on box-up cold-formed steel columns in fire

Cold-formed steel is a popular material with various advantages. Its easy production and assembly give engineer an option to speed the construction process. However, thinness relates to the major issue of buckling, especially when dealing with high temperature. The unprotected cold-formed steel beha...

Full description

Bibliographic Details
Main Authors: Muftah, F., Sani, M. S. H. M., Osman, A. R., Mohammad, S., Ngian, S. P.
Format: Article
Language:English
Published: GEOMATE International Society 2018
Subjects:
Online Access:http://eprints.utm.my/79831/1/ShahrinMohammad2018_ExperimentalInvestigationonBoxUpColdFormed.pdf
_version_ 1796863117708230656
author Muftah, F.
Sani, M. S. H. M.
Osman, A. R.
Mohammad, S.
Ngian, S. P.
author_facet Muftah, F.
Sani, M. S. H. M.
Osman, A. R.
Mohammad, S.
Ngian, S. P.
author_sort Muftah, F.
collection ePrints
description Cold-formed steel is a popular material with various advantages. Its easy production and assembly give engineer an option to speed the construction process. However, thinness relates to the major issue of buckling, especially when dealing with high temperature. The unprotected cold-formed steel behaviour under fire is expected to have a little strength as compared to hot-rolled steel. Information on such behaviour is still limited. Fire resistance testing on built-up box CFS column was presented in this paper. Two fire resistance tests were carried out under compression load. The Standard ISO 834 Fire Resistance Test under 50% and 70% degree of utilisation measured the temperatures at several points of the steel column surface by using a surface thermocouple and axial column deformation. For reference purpose, one same static test at ambient temperature was carried out to assess the load bearing capacity. Results found that the failure temperature of built-up CFS could reach up to 515 °C and 443 °C within 8 minutes and 7 minutes resistant time for 50 % and 70% degree of utilisation, respectively. Based on deformation analysis, buckling temperature of the column was 448 °C and 394 °C with a critical time of 7 minutes for 50 % and 70% degree of utilisation, respectively. This concluded that the higher degree of utilisation results in lower critical temperatures of the columns.
first_indexed 2024-03-05T20:21:54Z
format Article
id utm.eprints-79831
institution Universiti Teknologi Malaysia - ePrints
language English
last_indexed 2024-03-05T20:21:54Z
publishDate 2018
publisher GEOMATE International Society
record_format dspace
spelling utm.eprints-798312019-01-28T06:56:18Z http://eprints.utm.my/79831/ Experimental investigation on box-up cold-formed steel columns in fire Muftah, F. Sani, M. S. H. M. Osman, A. R. Mohammad, S. Ngian, S. P. TA Engineering (General). Civil engineering (General) Cold-formed steel is a popular material with various advantages. Its easy production and assembly give engineer an option to speed the construction process. However, thinness relates to the major issue of buckling, especially when dealing with high temperature. The unprotected cold-formed steel behaviour under fire is expected to have a little strength as compared to hot-rolled steel. Information on such behaviour is still limited. Fire resistance testing on built-up box CFS column was presented in this paper. Two fire resistance tests were carried out under compression load. The Standard ISO 834 Fire Resistance Test under 50% and 70% degree of utilisation measured the temperatures at several points of the steel column surface by using a surface thermocouple and axial column deformation. For reference purpose, one same static test at ambient temperature was carried out to assess the load bearing capacity. Results found that the failure temperature of built-up CFS could reach up to 515 °C and 443 °C within 8 minutes and 7 minutes resistant time for 50 % and 70% degree of utilisation, respectively. Based on deformation analysis, buckling temperature of the column was 448 °C and 394 °C with a critical time of 7 minutes for 50 % and 70% degree of utilisation, respectively. This concluded that the higher degree of utilisation results in lower critical temperatures of the columns. GEOMATE International Society 2018 Article PeerReviewed application/pdf en http://eprints.utm.my/79831/1/ShahrinMohammad2018_ExperimentalInvestigationonBoxUpColdFormed.pdf Muftah, F. and Sani, M. S. H. M. and Osman, A. R. and Mohammad, S. and Ngian, S. P. (2018) Experimental investigation on box-up cold-formed steel columns in fire. International Journal of GEOMATE, 14 (44). pp. 58-64. ISSN 2186-2982 http://dx.doi.org/10.21660/2018.44.3538 DOI:10.21660/2018.44.3538
spellingShingle TA Engineering (General). Civil engineering (General)
Muftah, F.
Sani, M. S. H. M.
Osman, A. R.
Mohammad, S.
Ngian, S. P.
Experimental investigation on box-up cold-formed steel columns in fire
title Experimental investigation on box-up cold-formed steel columns in fire
title_full Experimental investigation on box-up cold-formed steel columns in fire
title_fullStr Experimental investigation on box-up cold-formed steel columns in fire
title_full_unstemmed Experimental investigation on box-up cold-formed steel columns in fire
title_short Experimental investigation on box-up cold-formed steel columns in fire
title_sort experimental investigation on box up cold formed steel columns in fire
topic TA Engineering (General). Civil engineering (General)
url http://eprints.utm.my/79831/1/ShahrinMohammad2018_ExperimentalInvestigationonBoxUpColdFormed.pdf
work_keys_str_mv AT muftahf experimentalinvestigationonboxupcoldformedsteelcolumnsinfire
AT sanimshm experimentalinvestigationonboxupcoldformedsteelcolumnsinfire
AT osmanar experimentalinvestigationonboxupcoldformedsteelcolumnsinfire
AT mohammads experimentalinvestigationonboxupcoldformedsteelcolumnsinfire
AT ngiansp experimentalinvestigationonboxupcoldformedsteelcolumnsinfire