Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation
This paper describes a three dimensional 5 kW PEMFC stack dynamic model. Both time and spatial dependence are considered. Dynamic response and sensitivity analyses of the stack are carried out using MATLAB and Simulink modules. The results highlights the three dimensional distributions of species co...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Malaysia Sabah
2003
|
Subjects: | |
Online Access: | http://eprints.utm.my/8027/1/ArshadAhmad2003_DynamicBehaviourAndSensitivityAnalysis.pdf |
_version_ | 1825910139816771584 |
---|---|
author | Ahmad, Arshad Ramli, Ahmad Raoof |
author_facet | Ahmad, Arshad Ramli, Ahmad Raoof |
author_sort | Ahmad, Arshad |
collection | ePrints |
description | This paper describes a three dimensional 5 kW PEMFC stack dynamic model. Both time and spatial dependence are considered. Dynamic response and sensitivity analyses of the stack are carried out using MATLAB and Simulink modules. The results highlights the three dimensional distributions of species concentrations, power density and temperature of model. The effects of feed flowrates on the stack power performance are illustrated. The results confirmed that the model developed as a reasonable representation of the fuel cell stack system. |
first_indexed | 2024-03-05T18:12:35Z |
format | Article |
id | utm.eprints-8027 |
institution | Universiti Teknologi Malaysia - ePrints |
language | English |
last_indexed | 2024-03-05T18:12:35Z |
publishDate | 2003 |
publisher | Universiti Malaysia Sabah |
record_format | dspace |
spelling | utm.eprints-80272010-06-02T01:50:49Z http://eprints.utm.my/8027/ Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation Ahmad, Arshad Ramli, Ahmad Raoof T Technology (General) This paper describes a three dimensional 5 kW PEMFC stack dynamic model. Both time and spatial dependence are considered. Dynamic response and sensitivity analyses of the stack are carried out using MATLAB and Simulink modules. The results highlights the three dimensional distributions of species concentrations, power density and temperature of model. The effects of feed flowrates on the stack power performance are illustrated. The results confirmed that the model developed as a reasonable representation of the fuel cell stack system. Universiti Malaysia Sabah 2003 Article PeerReviewed application/pdf en http://eprints.utm.my/8027/1/ArshadAhmad2003_DynamicBehaviourAndSensitivityAnalysis.pdf Ahmad, Arshad and Ramli, Ahmad Raoof (2003) Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation. Proceedings of International Conference On Chemical and Bioprocess Engineering . pp. 867-874. |
spellingShingle | T Technology (General) Ahmad, Arshad Ramli, Ahmad Raoof Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation |
title | Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation |
title_full | Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation |
title_fullStr | Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation |
title_full_unstemmed | Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation |
title_short | Dynamic behaviour and sensitivity analysis of 5kW PEMFC stack simulation |
title_sort | dynamic behaviour and sensitivity analysis of 5kw pemfc stack simulation |
topic | T Technology (General) |
url | http://eprints.utm.my/8027/1/ArshadAhmad2003_DynamicBehaviourAndSensitivityAnalysis.pdf |
work_keys_str_mv | AT ahmadarshad dynamicbehaviourandsensitivityanalysisof5kwpemfcstacksimulation AT ramliahmadraoof dynamicbehaviourandsensitivityanalysisof5kwpemfcstacksimulation |