Optimisation of wastewater volume of single chamber biological cathodic protection system

In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and opt...

Full description

Bibliographic Details
Main Authors: Wan Ali, Wan Nor Azita, Azman, Anis Fitri Afira, Samsudin, Mohd. Dinie Muhaimin, Mohd. Zaini Makhtar, Muaz, Ibrahim, Norazana, Md. Kasmani, Rafiziana
Format: Article
Published: AIDIC Servizi S.r.l. 2018
Subjects:
_version_ 1796863832332697600
author Wan Ali, Wan Nor Azita
Azman, Anis Fitri Afira
Samsudin, Mohd. Dinie Muhaimin
Mohd. Zaini Makhtar, Muaz
Ibrahim, Norazana
Md. Kasmani, Rafiziana
author_facet Wan Ali, Wan Nor Azita
Azman, Anis Fitri Afira
Samsudin, Mohd. Dinie Muhaimin
Mohd. Zaini Makhtar, Muaz
Ibrahim, Norazana
Md. Kasmani, Rafiziana
author_sort Wan Ali, Wan Nor Azita
collection ePrints
description In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and optimise the effect of volume ratio of wastewater to the sand on biological CP performance by using Taguchi method. The maximum performance of biological CP in this study was obtained at the largest volume ratio. The orthogonal array and the signal-to-noise ratio (S/N) were employed to study the effect of volume ratio on performance of biological CP. The CP potential vs. copper sulfate electrode (CSE) was -835 mV. It shows that the corrosion of carbon steel pipe was reduced since the native potential of the carbon steel pipe vs. CSE was -531 mV.
first_indexed 2024-03-05T20:32:40Z
format Article
id utm.eprints-84379
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T20:32:40Z
publishDate 2018
publisher AIDIC Servizi S.r.l.
record_format dspace
spelling utm.eprints-843792019-12-28T01:55:37Z http://eprints.utm.my/84379/ Optimisation of wastewater volume of single chamber biological cathodic protection system Wan Ali, Wan Nor Azita Azman, Anis Fitri Afira Samsudin, Mohd. Dinie Muhaimin Mohd. Zaini Makhtar, Muaz Ibrahim, Norazana Md. Kasmani, Rafiziana TP Chemical technology In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and optimise the effect of volume ratio of wastewater to the sand on biological CP performance by using Taguchi method. The maximum performance of biological CP in this study was obtained at the largest volume ratio. The orthogonal array and the signal-to-noise ratio (S/N) were employed to study the effect of volume ratio on performance of biological CP. The CP potential vs. copper sulfate electrode (CSE) was -835 mV. It shows that the corrosion of carbon steel pipe was reduced since the native potential of the carbon steel pipe vs. CSE was -531 mV. AIDIC Servizi S.r.l. 2018 Article PeerReviewed Wan Ali, Wan Nor Azita and Azman, Anis Fitri Afira and Samsudin, Mohd. Dinie Muhaimin and Mohd. Zaini Makhtar, Muaz and Ibrahim, Norazana and Md. Kasmani, Rafiziana (2018) Optimisation of wastewater volume of single chamber biological cathodic protection system. Chemical Engineering Transactions, 63 . pp. 415-420. ISSN 2283-9216 https://doi.org/0.3303/CET1863070
spellingShingle TP Chemical technology
Wan Ali, Wan Nor Azita
Azman, Anis Fitri Afira
Samsudin, Mohd. Dinie Muhaimin
Mohd. Zaini Makhtar, Muaz
Ibrahim, Norazana
Md. Kasmani, Rafiziana
Optimisation of wastewater volume of single chamber biological cathodic protection system
title Optimisation of wastewater volume of single chamber biological cathodic protection system
title_full Optimisation of wastewater volume of single chamber biological cathodic protection system
title_fullStr Optimisation of wastewater volume of single chamber biological cathodic protection system
title_full_unstemmed Optimisation of wastewater volume of single chamber biological cathodic protection system
title_short Optimisation of wastewater volume of single chamber biological cathodic protection system
title_sort optimisation of wastewater volume of single chamber biological cathodic protection system
topic TP Chemical technology
work_keys_str_mv AT wanaliwannorazita optimisationofwastewatervolumeofsinglechamberbiologicalcathodicprotectionsystem
AT azmananisfitriafira optimisationofwastewatervolumeofsinglechamberbiologicalcathodicprotectionsystem
AT samsudinmohddiniemuhaimin optimisationofwastewatervolumeofsinglechamberbiologicalcathodicprotectionsystem
AT mohdzainimakhtarmuaz optimisationofwastewatervolumeofsinglechamberbiologicalcathodicprotectionsystem
AT ibrahimnorazana optimisationofwastewatervolumeofsinglechamberbiologicalcathodicprotectionsystem
AT mdkasmanirafiziana optimisationofwastewatervolumeofsinglechamberbiologicalcathodicprotectionsystem