The optimum location of outrigger in reducing the along-wind and across-wind responses

Outrigger is one of the many tall building structural systems that are used to reduce the building responses to wind. However, it is not known where the outrigger should be placed so that the responses of the tall building due to wind can be minimized. Thus, 64-story reinforced concrete buildings wi...

Full description

Bibliographic Details
Main Authors: Abd. Samal, Roslinda, Mohd. Ali, Nasty, Marsono , Abdul Kadir
Format: Article
Language:English
Published: Faculty of Civil Engineering, Universiti Teknologi Malaysia 2008
Subjects:
Online Access:http://eprints.utm.my/8524/1/RoslidaAbdSamat2008_TheOptimumLocationofOuttrigger.pdf
_version_ 1796854397503799296
author Abd. Samal, Roslinda
Mohd. Ali, Nasty
Marsono , Abdul Kadir
author_facet Abd. Samal, Roslinda
Mohd. Ali, Nasty
Marsono , Abdul Kadir
author_sort Abd. Samal, Roslinda
collection ePrints
description Outrigger is one of the many tall building structural systems that are used to reduce the building responses to wind. However, it is not known where the outrigger should be placed so that the responses of the tall building due to wind can be minimized. Thus, 64-story reinforced concrete buildings with the ratio of height to the breadth of 6:1 are studied in order to determine the optimum location to construct the outriggers to minimize the along-wind and across-wind responses. Buildings with different location of outriggers are analysed by a structural analysis software in order to determine the natural frequencies and eigenvectors in the along-wind and across-wind direction. The along-wind responses are determined by employing the procedures from the ASCE 7-02 while the across-wind responses of the buildings are calculated based on the procedures and wind tunnel data available in a data base of aerodynamic load. The database is comprised of high-frequency base balance measurements on a host of isolated tall buildings models. Results from the analysis shows that the optimum location to construct the outriggers is between one third to two third of the height of the building
first_indexed 2024-03-05T18:13:42Z
format Article
id utm.eprints-8524
institution Universiti Teknologi Malaysia - ePrints
language English
last_indexed 2024-03-05T18:13:42Z
publishDate 2008
publisher Faculty of Civil Engineering, Universiti Teknologi Malaysia
record_format dspace
spelling utm.eprints-85242010-08-18T02:22:29Z http://eprints.utm.my/8524/ The optimum location of outrigger in reducing the along-wind and across-wind responses Abd. Samal, Roslinda Mohd. Ali, Nasty Marsono , Abdul Kadir TA Engineering (General). Civil engineering (General) Outrigger is one of the many tall building structural systems that are used to reduce the building responses to wind. However, it is not known where the outrigger should be placed so that the responses of the tall building due to wind can be minimized. Thus, 64-story reinforced concrete buildings with the ratio of height to the breadth of 6:1 are studied in order to determine the optimum location to construct the outriggers to minimize the along-wind and across-wind responses. Buildings with different location of outriggers are analysed by a structural analysis software in order to determine the natural frequencies and eigenvectors in the along-wind and across-wind direction. The along-wind responses are determined by employing the procedures from the ASCE 7-02 while the across-wind responses of the buildings are calculated based on the procedures and wind tunnel data available in a data base of aerodynamic load. The database is comprised of high-frequency base balance measurements on a host of isolated tall buildings models. Results from the analysis shows that the optimum location to construct the outriggers is between one third to two third of the height of the building Faculty of Civil Engineering, Universiti Teknologi Malaysia 2008 Article PeerReviewed application/pdf en http://eprints.utm.my/8524/1/RoslidaAbdSamat2008_TheOptimumLocationofOuttrigger.pdf Abd. Samal, Roslinda and Mohd. Ali, Nasty and Marsono , Abdul Kadir (2008) The optimum location of outrigger in reducing the along-wind and across-wind responses. Malaysian Journal of Civil Engineering, 20 (2). pp. 223-241. ISSN 1823-7843 http://web.utm.my/ipasa/index.php?option=content&task=view&id=734&Itemid
spellingShingle TA Engineering (General). Civil engineering (General)
Abd. Samal, Roslinda
Mohd. Ali, Nasty
Marsono , Abdul Kadir
The optimum location of outrigger in reducing the along-wind and across-wind responses
title The optimum location of outrigger in reducing the along-wind and across-wind responses
title_full The optimum location of outrigger in reducing the along-wind and across-wind responses
title_fullStr The optimum location of outrigger in reducing the along-wind and across-wind responses
title_full_unstemmed The optimum location of outrigger in reducing the along-wind and across-wind responses
title_short The optimum location of outrigger in reducing the along-wind and across-wind responses
title_sort optimum location of outrigger in reducing the along wind and across wind responses
topic TA Engineering (General). Civil engineering (General)
url http://eprints.utm.my/8524/1/RoslidaAbdSamat2008_TheOptimumLocationofOuttrigger.pdf
work_keys_str_mv AT abdsamalroslinda theoptimumlocationofoutriggerinreducingthealongwindandacrosswindresponses
AT mohdalinasty theoptimumlocationofoutriggerinreducingthealongwindandacrosswindresponses
AT marsonoabdulkadir theoptimumlocationofoutriggerinreducingthealongwindandacrosswindresponses
AT abdsamalroslinda optimumlocationofoutriggerinreducingthealongwindandacrosswindresponses
AT mohdalinasty optimumlocationofoutriggerinreducingthealongwindandacrosswindresponses
AT marsonoabdulkadir optimumlocationofoutriggerinreducingthealongwindandacrosswindresponses