Review on column fire resistance design for concrete filled steel tube
The use of concrete filled steel tube (CFST) columns offers an alternative for providing the required fire resistance and load bearing capacity, making its use in medium and high rise structures are highly popular. This paper aims to review the previous studies on CFST column under fire. The standar...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Penerbit UTM Press
2018
|
Subjects: |
_version_ | 1796864225670332416 |
---|---|
author | Kado, Bishir Mohammad, Shahrin Lee, Yeong Huei Shek, Poi Ngian Ab. Kadir, Mariyana Aida Muftah, Fadhluhartini |
author_facet | Kado, Bishir Mohammad, Shahrin Lee, Yeong Huei Shek, Poi Ngian Ab. Kadir, Mariyana Aida Muftah, Fadhluhartini |
author_sort | Kado, Bishir |
collection | ePrints |
description | The use of concrete filled steel tube (CFST) columns offers an alternative for providing the required fire resistance and load bearing capacity, making its use in medium and high rise structures are highly popular. This paper aims to review the previous studies on CFST column under fire. The standards or codes of practice used in fire resistance designs have been highlighted. The design of the CFST column is summarised with previous investigations on experiments and numerical modelling at ambient temperature and elevated temperature. Different conclusions were drawn depending on the material’s properties, considered parameters and the method used for the investigations. Outer diameter or width of the steel tube, steel tube thickness, concrete grade, column length, and eccentricity of loadings are among the parameters that affects the structural behaviour of CFST columns under fire. Several numerical analyses software were adequately used for simulating the behaviour of CFST columns at elevated temperatures, and validated using experimental results. Furthermore, the advantages of using the fire resistance design approaches on CFST columns filled with lightweight foamed concrete is highlighted. In conclusion, there is the need for more studies on standard fire tests of CFST column filled with light weight foamed concrete which is not covered in the current design guide. |
first_indexed | 2024-03-05T20:38:41Z |
format | Article |
id | utm.eprints-86348 |
institution | Universiti Teknologi Malaysia - ePrints |
last_indexed | 2024-03-05T20:38:41Z |
publishDate | 2018 |
publisher | Penerbit UTM Press |
record_format | dspace |
spelling | utm.eprints-863482020-08-31T14:02:30Z http://eprints.utm.my/86348/ Review on column fire resistance design for concrete filled steel tube Kado, Bishir Mohammad, Shahrin Lee, Yeong Huei Shek, Poi Ngian Ab. Kadir, Mariyana Aida Muftah, Fadhluhartini TA Engineering (General). Civil engineering (General) The use of concrete filled steel tube (CFST) columns offers an alternative for providing the required fire resistance and load bearing capacity, making its use in medium and high rise structures are highly popular. This paper aims to review the previous studies on CFST column under fire. The standards or codes of practice used in fire resistance designs have been highlighted. The design of the CFST column is summarised with previous investigations on experiments and numerical modelling at ambient temperature and elevated temperature. Different conclusions were drawn depending on the material’s properties, considered parameters and the method used for the investigations. Outer diameter or width of the steel tube, steel tube thickness, concrete grade, column length, and eccentricity of loadings are among the parameters that affects the structural behaviour of CFST columns under fire. Several numerical analyses software were adequately used for simulating the behaviour of CFST columns at elevated temperatures, and validated using experimental results. Furthermore, the advantages of using the fire resistance design approaches on CFST columns filled with lightweight foamed concrete is highlighted. In conclusion, there is the need for more studies on standard fire tests of CFST column filled with light weight foamed concrete which is not covered in the current design guide. Penerbit UTM Press 2018-11 Article PeerReviewed Kado, Bishir and Mohammad, Shahrin and Lee, Yeong Huei and Shek, Poi Ngian and Ab. Kadir, Mariyana Aida and Muftah, Fadhluhartini (2018) Review on column fire resistance design for concrete filled steel tube. Jurnal Teknologi, 80 (6). pp. 169-179. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v80.11114 DOI:10.11113/jt.v80.11114 |
spellingShingle | TA Engineering (General). Civil engineering (General) Kado, Bishir Mohammad, Shahrin Lee, Yeong Huei Shek, Poi Ngian Ab. Kadir, Mariyana Aida Muftah, Fadhluhartini Review on column fire resistance design for concrete filled steel tube |
title | Review on column fire resistance design for concrete filled steel tube |
title_full | Review on column fire resistance design for concrete filled steel tube |
title_fullStr | Review on column fire resistance design for concrete filled steel tube |
title_full_unstemmed | Review on column fire resistance design for concrete filled steel tube |
title_short | Review on column fire resistance design for concrete filled steel tube |
title_sort | review on column fire resistance design for concrete filled steel tube |
topic | TA Engineering (General). Civil engineering (General) |
work_keys_str_mv | AT kadobishir reviewoncolumnfireresistancedesignforconcretefilledsteeltube AT mohammadshahrin reviewoncolumnfireresistancedesignforconcretefilledsteeltube AT leeyeonghuei reviewoncolumnfireresistancedesignforconcretefilledsteeltube AT shekpoingian reviewoncolumnfireresistancedesignforconcretefilledsteeltube AT abkadirmariyanaaida reviewoncolumnfireresistancedesignforconcretefilledsteeltube AT muftahfadhluhartini reviewoncolumnfireresistancedesignforconcretefilledsteeltube |