Review on column fire resistance design for concrete filled steel tube

The use of concrete filled steel tube (CFST) columns offers an alternative for providing the required fire resistance and load bearing capacity, making its use in medium and high rise structures are highly popular. This paper aims to review the previous studies on CFST column under fire. The standar...

Full description

Bibliographic Details
Main Authors: Kado, Bishir, Mohammad, Shahrin, Lee, Yeong Huei, Shek, Poi Ngian, Ab. Kadir, Mariyana Aida, Muftah, Fadhluhartini
Format: Article
Published: Penerbit UTM Press 2018
Subjects:
_version_ 1796864225670332416
author Kado, Bishir
Mohammad, Shahrin
Lee, Yeong Huei
Shek, Poi Ngian
Ab. Kadir, Mariyana Aida
Muftah, Fadhluhartini
author_facet Kado, Bishir
Mohammad, Shahrin
Lee, Yeong Huei
Shek, Poi Ngian
Ab. Kadir, Mariyana Aida
Muftah, Fadhluhartini
author_sort Kado, Bishir
collection ePrints
description The use of concrete filled steel tube (CFST) columns offers an alternative for providing the required fire resistance and load bearing capacity, making its use in medium and high rise structures are highly popular. This paper aims to review the previous studies on CFST column under fire. The standards or codes of practice used in fire resistance designs have been highlighted. The design of the CFST column is summarised with previous investigations on experiments and numerical modelling at ambient temperature and elevated temperature. Different conclusions were drawn depending on the material’s properties, considered parameters and the method used for the investigations. Outer diameter or width of the steel tube, steel tube thickness, concrete grade, column length, and eccentricity of loadings are among the parameters that affects the structural behaviour of CFST columns under fire. Several numerical analyses software were adequately used for simulating the behaviour of CFST columns at elevated temperatures, and validated using experimental results. Furthermore, the advantages of using the fire resistance design approaches on CFST columns filled with lightweight foamed concrete is highlighted. In conclusion, there is the need for more studies on standard fire tests of CFST column filled with light weight foamed concrete which is not covered in the current design guide.
first_indexed 2024-03-05T20:38:41Z
format Article
id utm.eprints-86348
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T20:38:41Z
publishDate 2018
publisher Penerbit UTM Press
record_format dspace
spelling utm.eprints-863482020-08-31T14:02:30Z http://eprints.utm.my/86348/ Review on column fire resistance design for concrete filled steel tube Kado, Bishir Mohammad, Shahrin Lee, Yeong Huei Shek, Poi Ngian Ab. Kadir, Mariyana Aida Muftah, Fadhluhartini TA Engineering (General). Civil engineering (General) The use of concrete filled steel tube (CFST) columns offers an alternative for providing the required fire resistance and load bearing capacity, making its use in medium and high rise structures are highly popular. This paper aims to review the previous studies on CFST column under fire. The standards or codes of practice used in fire resistance designs have been highlighted. The design of the CFST column is summarised with previous investigations on experiments and numerical modelling at ambient temperature and elevated temperature. Different conclusions were drawn depending on the material’s properties, considered parameters and the method used for the investigations. Outer diameter or width of the steel tube, steel tube thickness, concrete grade, column length, and eccentricity of loadings are among the parameters that affects the structural behaviour of CFST columns under fire. Several numerical analyses software were adequately used for simulating the behaviour of CFST columns at elevated temperatures, and validated using experimental results. Furthermore, the advantages of using the fire resistance design approaches on CFST columns filled with lightweight foamed concrete is highlighted. In conclusion, there is the need for more studies on standard fire tests of CFST column filled with light weight foamed concrete which is not covered in the current design guide. Penerbit UTM Press 2018-11 Article PeerReviewed Kado, Bishir and Mohammad, Shahrin and Lee, Yeong Huei and Shek, Poi Ngian and Ab. Kadir, Mariyana Aida and Muftah, Fadhluhartini (2018) Review on column fire resistance design for concrete filled steel tube. Jurnal Teknologi, 80 (6). pp. 169-179. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v80.11114 DOI:10.11113/jt.v80.11114
spellingShingle TA Engineering (General). Civil engineering (General)
Kado, Bishir
Mohammad, Shahrin
Lee, Yeong Huei
Shek, Poi Ngian
Ab. Kadir, Mariyana Aida
Muftah, Fadhluhartini
Review on column fire resistance design for concrete filled steel tube
title Review on column fire resistance design for concrete filled steel tube
title_full Review on column fire resistance design for concrete filled steel tube
title_fullStr Review on column fire resistance design for concrete filled steel tube
title_full_unstemmed Review on column fire resistance design for concrete filled steel tube
title_short Review on column fire resistance design for concrete filled steel tube
title_sort review on column fire resistance design for concrete filled steel tube
topic TA Engineering (General). Civil engineering (General)
work_keys_str_mv AT kadobishir reviewoncolumnfireresistancedesignforconcretefilledsteeltube
AT mohammadshahrin reviewoncolumnfireresistancedesignforconcretefilledsteeltube
AT leeyeonghuei reviewoncolumnfireresistancedesignforconcretefilledsteeltube
AT shekpoingian reviewoncolumnfireresistancedesignforconcretefilledsteeltube
AT abkadirmariyanaaida reviewoncolumnfireresistancedesignforconcretefilledsteeltube
AT muftahfadhluhartini reviewoncolumnfireresistancedesignforconcretefilledsteeltube