Infrared tomography : data distribution system for real-time mass flow rate measurement
The system developed in this research has the objective of measuring mass flow rate in an online mode. If a single computer is used as data processing unit, a longer time is needed to produce a measurement result. In the research carried out by previous researcher shows about 11.2 seconds is needed...
Главные авторы: | , , , , |
---|---|
Формат: | Статья |
Язык: | English |
Опубликовано: |
International Frequency Sensors Association (IFSA)
2007
|
Предметы: | |
Online-ссылка: | http://eprints.utm.my/8663/1/8663.pdf |
_version_ | 1825910232009670656 |
---|---|
author | Abdul Rahim, Ruzairi Pang, Jon Fea Chan, Kok San Leong, Lai Chen Rahiman, Mohd. Hafiz Fazalul |
author_facet | Abdul Rahim, Ruzairi Pang, Jon Fea Chan, Kok San Leong, Lai Chen Rahiman, Mohd. Hafiz Fazalul |
author_sort | Abdul Rahim, Ruzairi |
collection | ePrints |
description | The system developed in this research has the objective of measuring mass flow rate in an online mode. If a single computer is used as data processing unit, a longer time is needed to produce a measurement result. In the research carried out by previous researcher shows about 11.2 seconds is needed to obtain one mass flow rate result in the offline mode (using offline data). This insufficient real-time result will cause problems in a feedback control process when applying the system on industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit. |
first_indexed | 2024-03-05T18:14:01Z |
format | Article |
id | utm.eprints-8663 |
institution | Universiti Teknologi Malaysia - ePrints |
language | English |
last_indexed | 2024-03-05T18:14:01Z |
publishDate | 2007 |
publisher | International Frequency Sensors Association (IFSA) |
record_format | dspace |
spelling | utm.eprints-86632017-10-19T01:05:39Z http://eprints.utm.my/8663/ Infrared tomography : data distribution system for real-time mass flow rate measurement Abdul Rahim, Ruzairi Pang, Jon Fea Chan, Kok San Leong, Lai Chen Rahiman, Mohd. Hafiz Fazalul TK Electrical engineering. Electronics Nuclear engineering The system developed in this research has the objective of measuring mass flow rate in an online mode. If a single computer is used as data processing unit, a longer time is needed to produce a measurement result. In the research carried out by previous researcher shows about 11.2 seconds is needed to obtain one mass flow rate result in the offline mode (using offline data). This insufficient real-time result will cause problems in a feedback control process when applying the system on industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit. International Frequency Sensors Association (IFSA) 2007 Article PeerReviewed application/pdf en http://eprints.utm.my/8663/1/8663.pdf Abdul Rahim, Ruzairi and Pang, Jon Fea and Chan, Kok San and Leong, Lai Chen and Rahiman, Mohd. Hafiz Fazalul (2007) Infrared tomography : data distribution system for real-time mass flow rate measurement. Sensors & Trandusers Journal, 80 (6). pp. 1277-1288. ISSN 1726-5479 http://www.sensorsportal.com/HTML/DIGEST/P_156.htm |
spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Abdul Rahim, Ruzairi Pang, Jon Fea Chan, Kok San Leong, Lai Chen Rahiman, Mohd. Hafiz Fazalul Infrared tomography : data distribution system for real-time mass flow rate measurement |
title | Infrared tomography : data distribution system for real-time mass flow rate measurement |
title_full | Infrared tomography : data distribution system for real-time mass flow rate measurement |
title_fullStr | Infrared tomography : data distribution system for real-time mass flow rate measurement |
title_full_unstemmed | Infrared tomography : data distribution system for real-time mass flow rate measurement |
title_short | Infrared tomography : data distribution system for real-time mass flow rate measurement |
title_sort | infrared tomography data distribution system for real time mass flow rate measurement |
topic | TK Electrical engineering. Electronics Nuclear engineering |
url | http://eprints.utm.my/8663/1/8663.pdf |
work_keys_str_mv | AT abdulrahimruzairi infraredtomographydatadistributionsystemforrealtimemassflowratemeasurement AT pangjonfea infraredtomographydatadistributionsystemforrealtimemassflowratemeasurement AT chankoksan infraredtomographydatadistributionsystemforrealtimemassflowratemeasurement AT leonglaichen infraredtomographydatadistributionsystemforrealtimemassflowratemeasurement AT rahimanmohdhafizfazalul infraredtomographydatadistributionsystemforrealtimemassflowratemeasurement |