Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors

Natural gas transmission pipelines age after a certain duration and are prone to internal anomalies due to the presence of carbon dioxide and hydrogen sulphide in the natural gas constituents. An intelligent pipeline inspection gauge (PIG) is one method that is used to evaluate pipeline integrity, p...

Full description

Bibliographic Details
Main Authors: Idroas, M., Abd. Aziz, M. A. F., Zakaria, Z., Ibrahim, M. N.
Format: Article
Published: Inderscience Publishers 2019
Subjects:
_version_ 1796864858826735616
author Idroas, M.
Abd. Aziz, M. A. F.
Zakaria, Z.
Ibrahim, M. N.
author_facet Idroas, M.
Abd. Aziz, M. A. F.
Zakaria, Z.
Ibrahim, M. N.
author_sort Idroas, M.
collection ePrints
description Natural gas transmission pipelines age after a certain duration and are prone to internal anomalies due to the presence of carbon dioxide and hydrogen sulphide in the natural gas constituents. An intelligent pipeline inspection gauge (PIG) is one method that is used to evaluate pipeline integrity, particularly damage resulting from corrosion threats. In this paper, an ultrasonic prototype PIG was developed that incorporates reflection mode ultrasonic sensors to measure anomalies on the internal surfaces of pipelines. The system consists of ultrasonic sensors, conditioning circuits and a data acquisition system (DAS). Sixty ultrasonic sensors were used mode at a frequency of 390 kHz. Surface anomalies were simulated at different locations on the internal surface of the pipeline to simulate changes in the pipe wall thickness. Variation in the measured distances implied the existence of surface anomalies. The results showed that the percentage error was less than ±0.50%.
first_indexed 2024-03-05T20:48:12Z
format Article
id utm.eprints-89582
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T20:48:12Z
publishDate 2019
publisher Inderscience Publishers
record_format dspace
spelling utm.eprints-895822021-02-22T05:55:59Z http://eprints.utm.my/89582/ Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors Idroas, M. Abd. Aziz, M. A. F. Zakaria, Z. Ibrahim, M. N. TP Chemical technology Natural gas transmission pipelines age after a certain duration and are prone to internal anomalies due to the presence of carbon dioxide and hydrogen sulphide in the natural gas constituents. An intelligent pipeline inspection gauge (PIG) is one method that is used to evaluate pipeline integrity, particularly damage resulting from corrosion threats. In this paper, an ultrasonic prototype PIG was developed that incorporates reflection mode ultrasonic sensors to measure anomalies on the internal surfaces of pipelines. The system consists of ultrasonic sensors, conditioning circuits and a data acquisition system (DAS). Sixty ultrasonic sensors were used mode at a frequency of 390 kHz. Surface anomalies were simulated at different locations on the internal surface of the pipeline to simulate changes in the pipe wall thickness. Variation in the measured distances implied the existence of surface anomalies. The results showed that the percentage error was less than ±0.50%. Inderscience Publishers 2019 Article PeerReviewed Idroas, M. and Abd. Aziz, M. A. F. and Zakaria, Z. and Ibrahim, M. N. (2019) Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors. International Journal of Oil, Gas and Coal Technology, 20 (2). pp. 212-223. ISSN 1753-3317 http://dx.doi.org/10.1504/IJOGCT.2019.097449
spellingShingle TP Chemical technology
Idroas, M.
Abd. Aziz, M. A. F.
Zakaria, Z.
Ibrahim, M. N.
Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors
title Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors
title_full Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors
title_fullStr Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors
title_full_unstemmed Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors
title_short Imaging of pipeline irregularities using a PIG system based on reflection mode ultrasonic sensors
title_sort imaging of pipeline irregularities using a pig system based on reflection mode ultrasonic sensors
topic TP Chemical technology
work_keys_str_mv AT idroasm imagingofpipelineirregularitiesusingapigsystembasedonreflectionmodeultrasonicsensors
AT abdazizmaf imagingofpipelineirregularitiesusingapigsystembasedonreflectionmodeultrasonicsensors
AT zakariaz imagingofpipelineirregularitiesusingapigsystembasedonreflectionmodeultrasonicsensors
AT ibrahimmn imagingofpipelineirregularitiesusingapigsystembasedonreflectionmodeultrasonicsensors