Seismic control of a building structure equip with hybrid mass damper using sliding mode control

This paper addresses the issue of the impact of controllers in suppressing the vibration of structural building during seismic. It is important to implement an appropriate controller to avoid a huge impact to the building structure from damage and collapse while earthquake occur. Sliding mode contro...

Full description

Bibliographic Details
Main Authors: Mamat, Normaisharah, Yakub, Fitri, Shaikh Salim, Sheikh Ahmad Zaki, Ab. Rashid, Mohd. Zamzuri, Munawarah, Sharifah, Roslan, Shairatul Akma
Format: Conference or Workshop Item
Published: 2020
Subjects:
_version_ 1796864900853661696
author Mamat, Normaisharah
Yakub, Fitri
Shaikh Salim, Sheikh Ahmad Zaki
Ab. Rashid, Mohd. Zamzuri
Munawarah, Sharifah
Roslan, Shairatul Akma
author_facet Mamat, Normaisharah
Yakub, Fitri
Shaikh Salim, Sheikh Ahmad Zaki
Ab. Rashid, Mohd. Zamzuri
Munawarah, Sharifah
Roslan, Shairatul Akma
author_sort Mamat, Normaisharah
collection ePrints
description This paper addresses the issue of the impact of controllers in suppressing the vibration of structural building during seismic. It is important to implement an appropriate controller to avoid a huge impact to the building structure from damage and collapse while earthquake occur. Sliding mode controller (SMC) and proportional-integral-derivative (PID) are proposed to alleviate the vibration. SMC is selected as control strategy because of its robust control technique that can reject the disturbances while PID is known as simple control design. The simulation for two storey building equipped with structural control device which known as hybrid mass damper placed at the top floor of the structure that represent by mass, spring and damper are constructed by using Matlab/Simulink. The input excitation to the structure is taken from El Centro earthquake with magnitude of 6.9 Mw. The output response for the system generates displacement, velocity, control input, and frequency response. Based from the result, SMC has better performance compared to PID and overall SMC is success to suppress the building vibration according to the displacement performance obtained.
first_indexed 2024-03-05T20:48:50Z
format Conference or Workshop Item
id utm.eprints-89795
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T20:48:50Z
publishDate 2020
record_format dspace
spelling utm.eprints-897952021-03-04T02:45:51Z http://eprints.utm.my/89795/ Seismic control of a building structure equip with hybrid mass damper using sliding mode control Mamat, Normaisharah Yakub, Fitri Shaikh Salim, Sheikh Ahmad Zaki Ab. Rashid, Mohd. Zamzuri Munawarah, Sharifah Roslan, Shairatul Akma TA Engineering (General). Civil engineering (General) This paper addresses the issue of the impact of controllers in suppressing the vibration of structural building during seismic. It is important to implement an appropriate controller to avoid a huge impact to the building structure from damage and collapse while earthquake occur. Sliding mode controller (SMC) and proportional-integral-derivative (PID) are proposed to alleviate the vibration. SMC is selected as control strategy because of its robust control technique that can reject the disturbances while PID is known as simple control design. The simulation for two storey building equipped with structural control device which known as hybrid mass damper placed at the top floor of the structure that represent by mass, spring and damper are constructed by using Matlab/Simulink. The input excitation to the structure is taken from El Centro earthquake with magnitude of 6.9 Mw. The output response for the system generates displacement, velocity, control input, and frequency response. Based from the result, SMC has better performance compared to PID and overall SMC is success to suppress the building vibration according to the displacement performance obtained. 2020-07 Conference or Workshop Item PeerReviewed Mamat, Normaisharah and Yakub, Fitri and Shaikh Salim, Sheikh Ahmad Zaki and Ab. Rashid, Mohd. Zamzuri and Munawarah, Sharifah and Roslan, Shairatul Akma (2020) Seismic control of a building structure equip with hybrid mass damper using sliding mode control. In: 2nd Symposium on Intelligent Manufacturing and Mechatronics, SympoSIMM 2019, 8 July 2019 through 8 July 2019, Melaka, Malaysia. http://dx.doi.org/10.1007/978-981-13-9539-0_15
spellingShingle TA Engineering (General). Civil engineering (General)
Mamat, Normaisharah
Yakub, Fitri
Shaikh Salim, Sheikh Ahmad Zaki
Ab. Rashid, Mohd. Zamzuri
Munawarah, Sharifah
Roslan, Shairatul Akma
Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_full Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_fullStr Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_full_unstemmed Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_short Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_sort seismic control of a building structure equip with hybrid mass damper using sliding mode control
topic TA Engineering (General). Civil engineering (General)
work_keys_str_mv AT mamatnormaisharah seismiccontrolofabuildingstructureequipwithhybridmassdamperusingslidingmodecontrol
AT yakubfitri seismiccontrolofabuildingstructureequipwithhybridmassdamperusingslidingmodecontrol
AT shaikhsalimsheikhahmadzaki seismiccontrolofabuildingstructureequipwithhybridmassdamperusingslidingmodecontrol
AT abrashidmohdzamzuri seismiccontrolofabuildingstructureequipwithhybridmassdamperusingslidingmodecontrol
AT munawarahsharifah seismiccontrolofabuildingstructureequipwithhybridmassdamperusingslidingmodecontrol
AT roslanshairatulakma seismiccontrolofabuildingstructureequipwithhybridmassdamperusingslidingmodecontrol