The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective

An external fixator is a promising medical device that could provide optimum stability and reduce the rate of complications in treating bone fracture during intervention period. It is noted that the biomechanics behaviour of device can be altered by introducing more features such as material suitabi...

Full description

Bibliographic Details
Main Authors: Ramlee, Muhammad Hanif, Seng, Gan Hong, Ros Felip, Antonio, Abdul Kadir, Mohammed Rafiq
Format: Article
Published: Elsevier Ltd 2021
Subjects:
_version_ 1796866242075688960
author Ramlee, Muhammad Hanif
Seng, Gan Hong
Ros Felip, Antonio
Abdul Kadir, Mohammed Rafiq
author_facet Ramlee, Muhammad Hanif
Seng, Gan Hong
Ros Felip, Antonio
Abdul Kadir, Mohammed Rafiq
author_sort Ramlee, Muhammad Hanif
collection ePrints
description An external fixator is a promising medical device that could provide optimum stability and reduce the rate of complications in treating bone fracture during intervention period. It is noted that the biomechanics behaviour of device can be altered by introducing more features such as material suitability and additional components. Therefore, this study was conducted via finite element method to investigate the effects of additional hollow cylinder coated with external fixator screws in treating Type III pilon fracture. Finite element models which have been validated with experimental data were used to simulate stresses at the pin-bone interface and relative micromovement at interfragmentary fractures during swing (70 N load) and stance phases (350 N load). All bones and external fixators were assigned with isotropic material properties while the cartilages were simulated with hyper-elastic. For the hollow cylinder, polyethylene was assigned due to its properties which are equivalent to the bone. From the results, it is found that stresses at the pin-bone interface for the coated screws were reduced to 54% as compared to the conventional fixator. For the micromovement, there was no difference between both models, whereby the value was 0.03 mm. The results supported previously published literature, in which high stresses are unavoidable at the interface, fortunately, those stresses did not exceed the ultimate strength of bone, which is safe for treating patients. In conclusion, if patients are allowed to bear weight bearing, the external fixator with coated screws is a more favourable option to be fixed into the bone to avoid complications at the interface.
first_indexed 2024-03-05T21:09:12Z
format Article
id utm.eprints-96528
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T21:09:12Z
publishDate 2021
publisher Elsevier Ltd
record_format dspace
spelling utm.eprints-965282022-07-26T08:41:04Z http://eprints.utm.my/96528/ The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective Ramlee, Muhammad Hanif Seng, Gan Hong Ros Felip, Antonio Abdul Kadir, Mohammed Rafiq RD Surgery An external fixator is a promising medical device that could provide optimum stability and reduce the rate of complications in treating bone fracture during intervention period. It is noted that the biomechanics behaviour of device can be altered by introducing more features such as material suitability and additional components. Therefore, this study was conducted via finite element method to investigate the effects of additional hollow cylinder coated with external fixator screws in treating Type III pilon fracture. Finite element models which have been validated with experimental data were used to simulate stresses at the pin-bone interface and relative micromovement at interfragmentary fractures during swing (70 N load) and stance phases (350 N load). All bones and external fixators were assigned with isotropic material properties while the cartilages were simulated with hyper-elastic. For the hollow cylinder, polyethylene was assigned due to its properties which are equivalent to the bone. From the results, it is found that stresses at the pin-bone interface for the coated screws were reduced to 54% as compared to the conventional fixator. For the micromovement, there was no difference between both models, whereby the value was 0.03 mm. The results supported previously published literature, in which high stresses are unavoidable at the interface, fortunately, those stresses did not exceed the ultimate strength of bone, which is safe for treating patients. In conclusion, if patients are allowed to bear weight bearing, the external fixator with coated screws is a more favourable option to be fixed into the bone to avoid complications at the interface. Elsevier Ltd 2021 Article PeerReviewed Ramlee, Muhammad Hanif and Seng, Gan Hong and Ros Felip, Antonio and Abdul Kadir, Mohammed Rafiq (2021) The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective. Injury, 52 (8). pp. 2131-2141. ISSN 0020-1383 http://dx.doi.org/10.1016/j.injury.2021.03.017 DOI:10.1016/j.injury.2021.03.017
spellingShingle RD Surgery
Ramlee, Muhammad Hanif
Seng, Gan Hong
Ros Felip, Antonio
Abdul Kadir, Mohammed Rafiq
The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective
title The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective
title_full The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective
title_fullStr The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective
title_full_unstemmed The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective
title_short The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective
title_sort effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture a biomechanical perspective
topic RD Surgery
work_keys_str_mv AT ramleemuhammadhanif theeffectsofadditionalhollowcylindercoatedtoexternalfixatorscrewsfortreatingpilonfractureabiomechanicalperspective
AT sengganhong theeffectsofadditionalhollowcylindercoatedtoexternalfixatorscrewsfortreatingpilonfractureabiomechanicalperspective
AT rosfelipantonio theeffectsofadditionalhollowcylindercoatedtoexternalfixatorscrewsfortreatingpilonfractureabiomechanicalperspective
AT abdulkadirmohammedrafiq theeffectsofadditionalhollowcylindercoatedtoexternalfixatorscrewsfortreatingpilonfractureabiomechanicalperspective
AT ramleemuhammadhanif effectsofadditionalhollowcylindercoatedtoexternalfixatorscrewsfortreatingpilonfractureabiomechanicalperspective
AT sengganhong effectsofadditionalhollowcylindercoatedtoexternalfixatorscrewsfortreatingpilonfractureabiomechanicalperspective
AT rosfelipantonio effectsofadditionalhollowcylindercoatedtoexternalfixatorscrewsfortreatingpilonfractureabiomechanicalperspective
AT abdulkadirmohammedrafiq effectsofadditionalhollowcylindercoatedtoexternalfixatorscrewsfortreatingpilonfractureabiomechanicalperspective