Showing 1 - 13 results of 13 for search '"micronation"', query time: 0.06s Refine Results
  1. 1
  2. 2
  3. 3
  4. 4

    A low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlines by Burrows, P, Bett, DR, Blaskovic Kraljevic, N, Christian, G, Davis, MR, Perry, C, Apsimon, R, Constance, B, Gerbershagen, A, Resta Ĺopez, J

    Published 2012
    “…A low-latency, sub-micron resolution stripline beam position monitoring system has been developed for use in single-pass beamlines. …”
    Conference item
  5. 5
  6. 6

    Development of a fast, single-pass, micron-resolution beam position monitor signal processor: Beam test results from ATF2 by Apsimon, R, Bett, D, Burrows, P, Christian, G, Constance, B, Dabiri Khah, H, Perry, C, Resta Lopez, J, Swinson, C

    Published 2010
    “…We present the design of a stripline beam position monitor (BPM) signal processor with low latency (c. 10ns) and micron-level spatial resolution in single-pass mode. …”
    Conference item
  7. 7

    The Interaction Point Collision Feedback System at the International Linear Collider and its sensitivity to expected electromagnetic backgrounds by Clarke, C, Christine Clarke

    Published 2008
    “…It is concluded that micron-level resolution will not be aected by the ILC pair backgrounds. …”
    Thesis
  8. 8

    Engineering challenges of future particle accelerators by Burrows, P, IOP

    Published 2008
    “…The engineering challenges are immense. 30km-long straight tunnels must be drilled to house the accelerator, and components must be aligned and stabilised to microns over distances of kilometers. High-power superconducting niobium radio-frequency cavities will drive electron and positron beams to velocities approaching the speed of light. …”
    Journal article
  9. 9

    Latest performance results from the font5 intra-train beam position and angle feedbacksystem at ATF2 by Bett, DR, Blaskovic Kraljevic, N, Burrows, P, Christian, G, Davis, MR, Perry, C, Apsimon, R, Constance, B, Gerbershagen, A, Resta Lopez, J

    Published 2012
    “…The FONT5 intra-train feedbacksystem aims to stabilize the beam orbit by correcting both the position and angle jitter inthe vertical plane on bunch-tobunch time scales, providing micron-level stability at theentrance to the ATF2 final-focus system. …”
    Conference item
  10. 10

    Latest performance results from the FONT5 intra-train position and angle feedback system at ATF2 by Christian, G, Apsimon, R, Bett, DR, Burrows, P, Davis, MR, Gerbershagen, A, Perry, C, Constance, B, Resta-Lopez, J

    Published 2011
    “…The FONT5 intra-train feedback system aims to stabilise the beam orbit by correcting both the position and angle jitter in the vertical plane on bunch-to-bunch timescales, providing micron-level stability at the entrance to the ATF2 final-focus system. …”
    Journal article
  11. 11

    Development of a high-resolution, broad-band, stripline beam position monitoring system by Bett, DR, Kraljevic, N, Burrows, P, Christian, G, Davis, MR, Kim, Y, Perry, C, Apsimon, R, Constance, B, Lopez, JR

    Published 2013
    “…A low-latency, sub-micron resolution stripline beam position monitoring system has been developed and tested with beam at the KEK Accelerator Test Facility, where it has been used as part of a feedback system for beam stabilisation. …”
    Journal article
  12. 12

    A fast, custom FPGA-based signal processor and its applications to intra-train beam stabilisation by Christian, G, Blaskovic Kraljevic, N, Bodenstein, R, Bromwich, T, Burrows, P, Perry, C, Ramjaiwan, R, Roberts, J

    Published 2016
    “…Two examples of applications will also be presented: a position and angle bunch-by-bunch feedback system using strip-line beam position monitors to stabilise intra-train positional jitter to below the micron level with a latency less than 154 ns; and a phase feedforward system using RF cavity-based phase monitors to stabilise the downstream rms phase jitter to below 50 fs with a total latency less than the 380 ns beam time-of-flight.…”
    Conference item
  13. 13

    An intra-pulse fast feedback system for a future linear collider by Jolly, S

    Published 2003
    “…The results of these tests with the NLCTA short and long-pulse beam are presented, demonstrating a linear response to the position of the 180 ns long-pulse beam: measurements show a time constant of ~1.5 ns and a precision of better than 20 microns. A novel BPM processor for use at X-band, making use of the difference-over-sum processing technique, is also presented in detail, with results given for both short and long-pulse beams.…”
    Thesis