Showing 21 - 40 results of 189 for search '"Geomagic"', query time: 0.26s Refine Results
  1. 21

    Design of Customize Interbody Fusion Cages of Ti64ELI with Gradient Porosity by Selective Laser Melting Process by Cheng-Tang Pan, Che-Hsin Lin, Ya-Kang Huang, Jason S. C. Jang, Hsuan-Kai Lin, Che-Nan Kuo, De-Yao Lin, Jacob C. Huang

    Published 2021-03-01
    “…The medical imaging software InVesalius and 3D surface reconstruction software Geomagic Studio 12 (Raindrop Geomagic Inc., Morrisville, NC, USA) were utilized to establish the vertebra model, and ANSYS Workbench 16 (Ansys Inc., Canonsburg, PA, USA) simulation software was used to simulate the stress and strain of the motions including vertical body-weighted compression, flexion, extension, lateral bending, and rotation. …”
    Get full text
    Article
  2. 22

    VIRTUAL TEST APPLIED ON A 3D MODEL OF VERTEBRAL COLUMN by Vladimir ONTICA, Andrei TUDORA, Danut Nicolae TARNITA, Dragos Laurentiu POPA, George GHERGHINA, Bogdan CAPITANESCU

    Published 2019-05-01
    “…These models have been taken over in the Geomagic program where replenishment, triangle reduction and finishing techniques have been applied. …”
    Get full text
    Article
  3. 23

    VIRTUAL TEST APPLIED ON A 3D MODEL OF VERTEBRAL COLUMN by Vladimir Ontica, Andrei Tudora, Danut Nicolae Tarnita, Dragos Laurentiu Popa, George Gherghina, Bogdan Capitanescu

    Published 2019-05-01
    “…These models have been taken over in the Geomagic program where replenishment, triangle reduction and finishing techniques have been applied. …”
    Get full text
    Article
  4. 24

    VIRTUAL TEST APPLIED ON A 3D MODEL OF VERTEBRAL COLUMN by Vladimir Ontica, Andrei Tudora, Danut Nicolae Tarnita, Dragos Laurentiu Popa, George Gherghina, Bogdan Capitanescu

    Published 2019-05-01
    “…These models have been taken over in the Geomagic program where replenishment, triangle reduction and finishing techniques have been applied. …”
    Get full text
    Article
  5. 25

    Analyzing taphonomic deformation of ankylosaur skulls using retrodeformation and finite element analysis. by Victoria M Arbour, Philip J Currie

    Published 2012-01-01
    “…The software program Geomagic is used to retrodeform three-dimensional (3D) digital models of the ankylosaur skulls. …”
    Get full text
    Article
  6. 26

    VIRTUAL HUMAN HIP JOINT OBTAINED FROM CT IMAGES AND FEM TEST by Andrei Tudora, Vladimir Ontica, Danut Nicolae Tarnita, Dragos Laurentiu Popa, Daniel Cosmin Calin, Alin Oncescu, Bogdan Capitanescu, Dana Albulescu

    Published 2019-05-01
    “…These surfaces processed with the Geomagic program were transformed into virtual solids in SolidWorks. …”
    Get full text
    Article
  7. 27

    VIRTUAL HUMAN HIP JOINT OBTAINED FROM CT IMAGES AND FEM TEST by Andrei TUDORA, Vladimir ONTICA, Danut Nicolae TARNITA, Dragos Laurentiu POPA, Daniel Cosmin CALIN, Alin ONCESCU, Bogdan CAPITANESCU, Dana ALBULESCU

    Published 2019-05-01
    “…These surfaces processed with the Geomagic program were transformed into virtual solids in SolidWorks. …”
    Get full text
    Article
  8. 28

    The design and execution of a laboratory micro hydroelectric power plant by Elisabeta Spunei, Ionel Turcu, Alina Vișan

    Published 2021-11-01
    “…The hydraulic turbine is a Pelton turbine, rebuilt by fast prototyping in Geomagic Design X and printed on a 3 D printer. The turbine casing and the afferent ele-ments are made in-house. …”
    Article
  9. 29

    VIRTUAL HUMAN HIP JOINT OBTAINED FROM CT IMAGES AND FEM TEST by Andrei Tudora, Vladimir Ontica, Danut Nicolae Tarnita, Dragos Laurentiu Popa, Daniel Cosmin Calin, Alin Oncescu, Bogdan Capitanescu, Dana Albulescu

    Published 2019-05-01
    “…These surfaces processed with the Geomagic program were transformed into virtual solids in SolidWorks. …”
    Get full text
    Article
  10. 30

    Reverse Engineering of a Racing Motorbike Connecting Rod by Marco Freddi, Patrich Ferretti, Giulia Alessandri, Alfredo Liverani

    Published 2023-01-01
    “…By taking advantage of appropriate redesign CAD software (Geomagic Design X), a reconstruction can proceed within the high standard of accuracy imposed. …”
    Get full text
    Article
  11. 31

    3D display and printing by Chia, Meng Loong.

    Published 2013
    “…Data were also converted to STL format which is compatiable for 3D printing using the software – Geomagic Studio 10…”
    Get full text
    Final Year Project (FYP)
  12. 32

    STIFFNESS EVALUATION OF AEROSTATIC SPINDLE BASED ON NON-IDEAL CYLINDRICAL SURFACES by ZHAO ZeXiang, SHANG MengJiao, LIU RuYi, DOU WuYang

    Published 2019-01-01
    “…The non-ideal cylindrical surface model based on profile measurement was built by using Geomagic Studio software, and it was imported into UG12.0 to create the aerostatic bearing simulation model, which can be simulated by using ANSYS WORKBENCH software. …”
    Get full text
    Article
  13. 33

    ABOUT THREE-DIMENSIONAL MODELS OF OSTEOSYNTHESIS SYSTEMS by Ilaria Lorena PETROVICI, Mihai Catalin TENOVICI, Razvan Cristian VADUVA, Danut Nicolae TARNITA, Georgiana VINTILA, Dragos Laurentiu POPA

    Published 2019-05-01
    “…This model was "finalized" and modified using certain Geomagic techniques and then imported into SolidWorks. …”
    Get full text
    Article
  14. 34

    ABOUT THREE-DIMENSIONAL MODELS OF OSTEOSYNTHESIS SYSTEMS by Ilaria Loredana Petrovici, Mihai Catalin Tenovici, Razvan Cristian Vaduva, Danut Nicolae Tarnita, Georgiana Vintila, Dragos Laurentiu Popa

    Published 2019-05-01
    “…This model was "finalized" and modified using certain Geomagic techniques and then imported into SolidWorks. …”
    Get full text
    Article
  15. 35

    ABOUT THREE-DIMENSIONAL MODELS OF OSTEOSYNTHESIS SYSTEMS by Ilaria Loredana Petrovici, Mihai Catalin Tenovici, Razvan Cristian Vaduva, Danut Nicolae Tarnita, Georgiana Vintila, Dragos Laurentiu Popa

    Published 2019-05-01
    “…This model was "finalized" and modified using certain Geomagic techniques and then imported into SolidWorks. …”
    Get full text
    Article
  16. 36

    Research of Measurement Technology of 3D Tooth Surface Error of Non-circular Gear by Yongping Liu, Haiqing Deng, Fulin Liao, Changbin Dong, Jie Xu

    Published 2019-01-01
    “…Taking the elliptical gear as an example, the three-dimensional solid model of the non-circular gear is obtained by Einscan-SP scanner. The Geomagic Qualify software is used to align the solid model with the theoretical model, and the aligned tooth flanks are meshed to obtain the three-dimensional error value of the tooth surface of non-circular gear. …”
    Get full text
    Article
  17. 37

    Establishment of a Finite Element Model of Normal Nasal Bone and Analysis of Its Biomechanical Characteristics by Liuqing Zhang, XinYue Wang, Yiyuan Sun, Shuqin Wang, FuLong Zhang, Zhen Zhang

    Published 2023-01-01
    “…At the same time, the Geomagic software was used for relevant image processing, and the finite element software ANSYS was used to establish a finite element model to analyze the stress characteristics of the nasomaxillary complex. …”
    Get full text
    Article
  18. 38

    Virtual surgical planning is a useful tool in the surgical management of mandibular condylar fractures by Shubhechha Shakya, Kai-De Li, Dou Huang, Zuo-Qiang Liu, Xiao Zhang, Lei Liu

    Published 2022-05-01
    “…Variables including the rate of perfect reduction by radiological analysis, the average distance of deviation between preoperative and postoperative CT measurements using Geomagic software and postoperative clinical examinations (e.g., mouth opening, occlusion) were investigated for outcome measurement. …”
    Get full text
    Article
  19. 39

    Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy. by Yi-Jiao Zhao, Yu-Xue Xiong, Yong Wang

    Published 2017-01-01
    “…Registration based on the iterative closest point (ICP) algorithm was executed to overlap the test models to reference models, and "3D error" as a new measurement indicator calculated by reverse engineering software (Geomagic Studio) was used to evaluate the 3D global and partial (upper, middle, and lower parts of face) PA of each facial scanner. …”
    Get full text
    Article
  20. 40

    The finite element modeling and analysis of human lumbar segment herniation by Ju⁃ying HUANG, Hai⁃yun LI, Feng⁃zeng JIAN, Hua⁃gang YAN

    Published 2012-08-01
    “…Methods According to CT radiological data of a healthy adult, the vertebra and intervertebral disc of lumbar L3-5 segment were respectively reconstructed by Mimics 10.0 software and Geomagic 10.0 software. The FE model of L3-5 segment was reconstructed, and intact disc and herniated lumbar disc were created by adding the lumbar attaching ligaments into the simulating model and changing the corresponding material properties after the disc was extruded in Ansys software. …”
    Get full text
    Article