Showing 61 - 80 results of 104 for search '"Seal (device)"', query time: 0.17s Refine Results
  1. 61

    An Experimental Study of the Leakage Mechanism in Static Seals by Qiang Zhang, Xiaoqian Chen, Yiyong Huang, Xiang Zhang

    Published 2018-08-01
    “…The experimental device was also used to perform single-factor comparison experiments, which were then combined with the theoretical prediction model to analyze the effects of the sealing surface contact load, fluid pressure, and surface apparent size on the leak rate, so that theoretical support and experimental evidence for selecting the parameters of sealing device was provided.…”
    Get full text
    Article
  2. 62

    Sellado electrotérmico de vasos bipolares versus recorte de los vasos mesentéricos inferiores durante la proctectomía mínimamente invasiva by Mohamed Zuhdy, Islam H. Metwally, Ugo Elmore, Sameh Roshdy, Riccardo Rosati

    Published 2020-01-01
    “…Introduction: The introduction of new energy vessel sealing devices in minimally invasive proctectomy led to better hemostatic effect, less blood loss, and shorter operating time. …”
    Get full text
    Article
  3. 63

    Research and development of airtight biosafety containment facility for stainless steel structures by Zongxing Zhang, Jinhui Wu, Enlei Zhang, Siqing Zhao, Dong Wang, Ying Yi, Jiancheng Qi

    Published 2019-03-01
    “…Methods: An experimental study was conducted on a domestic high-level pathogenic microorganism model laboratory, considering the sealing process of the containment structure, including airtight doors, pass boxes, dunk tanks, through-wall pipeline sealing devices, and sealed floor drains. Results: The results indicate that the airtightness of the model laboratory containment structure meets the tightness requirements of a biosafety level-4 (BSL-4) laboratory. …”
    Get full text
    Article
  4. 64

    The Polymer-Based Technology in the Endovascular Treatment of Abdominal Aortic Aneurysms by Gianmarco de Donato, Edoardo Pasqui, Claudia Panzano, Brenda Brancaccio, Gaia Grottola, Giuseppe Galzerano, Domenico Benevento, Giancarlo Palasciano

    Published 2021-04-01
    “…This review underlines the two platforms that are based on a polymer technology: (1) the polymer-filled endobags, also known as Endovascular Aneurysm Sealing (EVAS) with Nellix stent graft; and (2) the O-ring EVAR polymer-based proximal neck sealing device, also known as an Ovation stent graft. …”
    Get full text
    Article
  5. 65

    Research and application of nuclear fuel embedded intelligent security monitoring technology by Haiyan Li, Min Zhu, Yang Yang, Lei Tu, Xiaojun Zhou, Shikuo Du

    Published 2022-11-01
    “…The system uses MCU as the control core, is equipped with motion detection and electronic seal devices, and realizes alarm functions such as identity authentication, unauthorized movement, and illegal unpacking real-time monitoring. …”
    Get full text
    Article
  6. 66

    Ultrasonic shears and bipolar vessel-sealing system for three-port laparoscopic ovariohysterectomy in dogs by N. Guizzo-Júnior, J.P.S. Feranti, M.C. Bairros, M. Bortoluzzi, A.C. Motta, L.W. Sartori, F.R. Santos, F.V. Tomazzoni, G. Brambatti, R.L. Guedes, M.A.M. Silva, M.V. Brun

    Published 2015-02-01
    “…In GI and GII the LigaSure(tm) impedance-controlled bipolar vessel-sealing device was used, differing in the size of trocartes used between groups, and in GIII Autosonix(tm) was used. …”
    Get full text
    Article
  7. 67

    Right-sided Bochdalek hernia containing retroperitoneal fat in the elderly: report of a case by Michihito Toda, Aya Yamamoto, Takashi Iwata

    Published 2019-05-01
    “…The neck of the mass was separated by a vessel-sealing device immediately above the hernia orifice. The defect of the diaphragm was repaired by direct suturing after completion of resection. …”
    Get full text
    Article
  8. 68

    Study on Additively Manufactured Mechanical Seal (Part 1) by Yoshiaki Takigahira, Yuki Maetani, Masanobu Ito, Norio Uemura, Kazuhito Ohashi

    Published 2022-12-01
    “…In oil refineries and petrochemical industries, a containment seal (CS) can be applied to a flashing hydrocarbon pump as a sealing device to prevent environmental pollution. It is extremely difficult to design a CS to ensure the contradictory functions of fluid-tight sealing and sealing-surface wear resistance, which are required under both conditions of dry running in gas and wet running in liquid. …”
    Get full text
    Article
  9. 69

    Numerical simulation of the laws of fracture propagation of multi-hole linear co-directional hydraulic fracturing by Weiyong Lu, Changchun He

    Published 2021-05-01
    “…Due to the existence of the borehole-sealing device, the three-dimensional hydraulic fracture first initiates and expands along the axial direction in the bare borehole section, then extends along the axial direction in the non-bare hole section and finally expands along the axial direction in the rock mass without the borehole. …”
    Get full text
    Article
  10. 70

    Laparoscopic resection of retroperitoneal paraganglioma close to caudal vena cava in a dog by Young Tae Park, Tomomi Minamoto

    Published 2021-11-01
    “…Based on these findings, laparoscopic tumour resection was performed using a vessel‐sealing device. The operation time was 136 minutes. Results The dog was stable after recovery from anaesthesia and discharged to home the next day. …”
    Get full text
    Article
  11. 71

    Design and Experimental Study on Divergent Magnetic Fluid Seal with Large Clearance and Dual Magnetic Sources by Xiaolong Yang, Yunyun Song, Peng Sun, You Li

    Published 2022-01-01
    “…In order to solve the leakage problem of rotating machinery under the condition of large clearance, a new type of divergent magnetic fluid sealing device with secondary magnetic source was designed. …”
    Get full text
    Article
  12. 72
  13. 73

    Indocyanine green lymphangiography for the management of lymphatic complications after vascular surgery by Marie Burgard, Floryn Cherbanyk, Emmanouil Psathas

    Published 2023-06-01
    “…Leaking lymphatics were identified and oversewn or closed by a vessel-sealing device. Results: All patients were initially managed with wound debridement and negative pressure wound therapy to quantify the amount of the lymphatic leak. …”
    Get full text
    Article
  14. 74

    Segmented sealing of cores and collection and test of escaped light hydrocarbons and its preliminary application by Yunjie BAO, Zhiming LI, Maowen LI, Menhui QIAN, Peng LIU, Ershe XU, Guoliang TAO, Zhenheng YANG

    Published 2020-05-01
    “…A new method for the segmented sealing of cores and the collection and test of light hydrocarbons was developed based on the patent "a segmented sealing device for cores and its instructions(2013101681829)". …”
    Get full text
    Article
  15. 75

    Wound Retractor Laparoscopic Port System for Laparoscopic Ovariectomy in <i>Panthera leo</i> by Luca Lacitignola, Pietro Laricchiuta, Annarita Imperante, Claudia Acquafredda, Marzia Stabile, Annalaura Scardia, Marta Guadalupi, Caterina Vicenti, Alberto Crovace, Francesco Staffieri

    Published 2022-03-01
    “…An ovariectomy was performed with a vessel-sealing device. We evaluated the surgery time and the intraoperative and early postoperative complications. …”
    Get full text
    Article
  16. 76

    Study on the Leakage and Inter-Stage Pressure Drop Characteristics of Two-Stage Finger Seal by Hailin Zhao, Hua Su, Guoding Chen, Yanchao Zhang

    Published 2021-03-01
    “…To solve the high leakage and high wear problems faced by sealing devices in aeroengines under the condition of high axial pressure difference, the two-stage finger seal is proposed in this paper. …”
    Get full text
    Article
  17. 77

    Resection of a thoracoabdominal ganglioneuroma via a retroperitoneal minimally invasive approach by Laura A. Galganski, Shinjiro Hirose, Payam Saadai

    Published 2019-01-01
    “…Development of the retroperitoneal space was achieved with both blunt dissection and a vessel-sealing device. The diaphragm was incised to resect the thoracic component of the mass. …”
    Get full text
    Article
  18. 78

    PROLONGED AIR LEAK AFTER LOBECTOMY IN LUNG CANCER PATIENTS by E. A. Toneev, D. V. Bazarov, O. V. Pikin, A. L. Charyshkin, A. A. Martynov, R. I. Lisyutin, A. Sh. Zulkarnyaev, E. P. Anokhina

    Published 2020-03-01
    “…Despite the progress in thoracic surgery including energy-based vessel-sealing devices and digital drainage systems, there is no universal agreement on the optimal treatment of patients with prolonged air-leaks. …”
    Get full text
    Article
  19. 79

    Laparoscopic partial pancreatectomy in a cat with exocrine pancreatic carcinoma by Jenna Menard, Nicole J Buote, Benjamin Rivard, Cheryl Balkman

    Published 2023-02-01
    “…A three-port technique using a 5 mm 0º telescope and bipolar vessel sealing device was performed to remove the entire left limb of the pancreas. …”
    Get full text
    Article
  20. 80

    Surgical resection of a middle mediastinal paraganglioma that caused diabetes by Kentaro Miura, Nobutaka Kobayashi, Hidetoshi Satomi

    Published 2020-09-01
    “…Surgery was performed using a vessel-sealing device; however, bleeding was persistent from the surrounding tissue. …”
    Get full text
    Article