2561
Modified palm oil fuel ash (pofa) as quartz replacement for the production of porcelain
Published 2019“…Due to formation of mullite and crystalline phase, the highest values of bulk density, compressive strength, and Vickers micro hardness were found to increase by addition of Fe2O3 at 5 wt. % as 2.515 g/cm3, 177.08 MPa and 829 HV respectively. …”
Get full text
Get full text
Get full text
Thesis -
2562
Analysis of mechanical properties and microstructure of multiple die cavity products produced in vertical and horizontal arrangement by gravity die casting
Published 2012“…The methodology used are vickers microhardness test, izod test, ensile test, density and porosity test and optical microscope inspection for all produced sample. …”
Get full text
Get full text
Get full text
Thesis -
2563
A comparative study on wear and corrosion behaviour of tungsten carbide-nickel (Wc-Ni) and tungsten carbide-cobalt (Wc-Co) high velocity oxy-fuel (HVOF) for carbon steel blade
Published 2017“…The hardness test was carried out by using Vickers micro-hardness tester with load of 490.3 mN (0.05 HV). …”
Get full text
Get full text
Get full text
Thesis -
2564
Influence of agglomeration phenomenon in machining of AISI D2 hardened steel using nano chromium powder mixed-EDM
Published 2020“…Digital Balance, SJ400 Mitutoyo, Shimadzu Vickers's tester, and SEM/EDS-Hitachi SU-1510 were invested to specify the Material Removal Rate (MRR), Tool Wear Rate (TWR), average surface roughness (Ra), Microhardness (MH), Recast Layer Thickness (RLT), and agglomeration ratio (%AG) after machining. …”
Get full text
Get full text
Get full text
Thesis -
2565
Alloying and aging treatment effect on the shape memory and damping properties of Cu-13Al-4Ni alloys
Published 2021“…The hardness of these alloys was determined using Vicker’s hardness tester. The shape memory effect was determined by compression test using an Instron universal testing machine. …”
Get full text
Thesis -
2566
Effect of substrate roughness and PVD deposition temperatures on hardness and wear performance of AlCrN-coated WC-Co
Published 2022“…The mechanical properties of the coated structure were further evaluated via Vickers microhardness and linear reciprocating tests. …”
Article -
2567
The properties of hot extruded binary magnesium calcium alloy for use as a biodegradable material within bone
Published 2010“…The hardness test results also showed that the Vickers hardness rates will increase by increasing the Ca content in the Mg-Ca alloys which was mainly due to the grain refinement and increment of Mg2Ca volume hindering the dislocations movements; According to the corrosion potential values, in-vitro corrosion rate and pH values, it was found out that binary Mg-Ca alloys with greater Ca contents corrodes faster than alloys containing less Ca; thus, increases the pH of the SBF solution and hydrogen evoluted from cathodic reaction more than others, that is predominantly due to grain refinement and increased Mg2Ca by adding more Ca. …”
Get full text
Thesis -
2568
Effect of Spherical Indenter Radius on Hardness and Extraction Mechanical Property of RAFM Steel under Ion Irradiation
Published 2023-12-01“…This paper investigated the impact of different spherical indenter radii (0.3, 1.0, and 10.0 μm) on predicting the Vickers hardness, yield strength, and elastic modulus of 3.5 MeV Fe2+ irradiated reduced activation ferritic/martensitic (RAFM) steel. …”
Article -
2569
Design of Experiment (Doe) Study Of Hydroxyapatite (Ha) For Load Bearing Application Via 2k Factorial Design.
Published 2013“…Bagi analisis fasa,sampel dicirikan menggunakan analisis pembelauan sinaran-X (XRD) dan ujian kekerasan Vickers digunakan untuk mengkaji kekerasan sampel. …”
Get full text
Thesis -
2570
Influence of varying concentrations of epoxy, rice husk, Al2O3, and Fe2O3 on the properties of brake friction materials prepared using hand layup method
Published 2023“…On the other hand, the density, hardness, flexural strength, flexural modulus, and wear rate values of this specimen were 1.23 g/cm3, 81.2 Vickers (HV), 57.24 MPa, 4.08 GPa, and 8.665 × 10−7 mm2/kg. …”
Get full text
Article -
2571
Characteristics of Mg-Based Sintered Alloy with Au Addition
Published 2023-02-01“…The article presents the results of the X-ray diffraction (XRD) method, density, scanning electron microscopy (SEM), particle size distributions, and Vickers microhardness and electrochemical properties via electrochemical impedance spectroscopy (EIS) and potentiodynamic immersion testing. …”
Get full text
Article -
2572
Study on the microstructure and properties of TiB2-CoCrFeNiW0.2 metal ceramic composites prepared by pressureless sintering
Published 2024-05-01“…The relative density, flexural strength, Vickers hardness, fracture toughness, and electrical resistivity of TiB2-30 wt%HEA are 99.7%, 680 MPa, 18.6 GPa, 6.4 MPa m1/2, and 5.7 × 10−7 Ω m, respectively.…”
Get full text
Article -
2573
Impact of aging temperature on the metallurgical and dry sliding wear behaviour of LM25 / Al2O3 metal matrix composite for potential automotive application
Published 2023-09-01“…The heat-treated alloy and composites were tested for their hardness on the Vickers microhardness tester. It was concluded that the aging temperature of 155 °C displayed significant enhancement in hardness values for tested samples. …”
Get full text
Article -
2574
Antimicrobial Cu-Doped TiO<sub>2</sub> Coatings on the β Ti-30Nb-5Mo Alloy by Micro-Arc Oxidation
Published 2023-12-01“…X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron and atomic force microscopies, contact angle, and Vickers microhardness techniques were applied to characterize the deposited coatings. …”
Get full text
Article -
2575
Global trends of acupuncture clinical research on analgesia from 2010 to 2023: a bibliometric and visualization analysis
Published 2024-04-01“…Notably, the most frequently cited reference was a systematic review of individual patient data on acupuncture carried out for chronic pain that was published by Vickers Andrew J in 2012 (156). Burst analysis identified frontier research areas for 2010–2020, encompassing network meta-analysis, case reports, dry needling, lumbar disc herniation, cancer, post-herpetic neuralgia, insomnia, and bibliometric analysis.ConclusionThis study outlines current trends and potential future research hotspots in clinical acupuncture analgesia over the past decade. …”
Get full text
Article -
2576
Influences of Successive Exposure to Bleaching and Fluoride Preparations on the Surface Hardness and Roughness of the Aged Resin Composite Restoratives
Published 2020-09-01“…Specimens’ surfaces were then tested for both surface hardness (Vickers hardness number (VHN), <i>n =</i> 10) and roughness (Ra, <i>n =</i> 10). …”
Get full text
Article -
2577
Study on solution expansion of the Cu-W immiscible alloy system by pulsed electron beam
Published 2022-12-01“…The surface hardness of the sintered and irradiated samples with different pulses was measured using the HVS-1000 Vickers hardness tester.ResultsThe results reveal that Cu(W) solid solutions were formed during the process of ball milling, and the mass fraction of the solute element W in the Cu(W) solid solution reaches 0.88% after 5 h of ball milling. …”
Get full text
Article -
2578
Ultra-dense (Bi, V, B)-oxide-added zircon ceramics fabricated by liquid-phase assisted spark plasma sintering (SPS)
Published 2023-01-01“…We found the ceramics exhibited thermal conductivity ranging from 0.39 to 0.61 Wm ^−1 K ^−1 at 373 K while the coefficient of thermal expansion was 2.3–4.0 × 10 ^−6 /°C and the Vickers hardness was obtained to be 9.52–12.66 GPa. …”
Get full text
Article -
2579
A comparative study on characteristics of composite (Cr3C2-NiCr) clad developed through diode laser and microwave energy
Published 2023-07-01“…The developed clads of both processes were characterized through a field emission scanning electron microscope (FE-SEM) attached with energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD) and assessment of Vickers microhardness. The Cr3C2-NiCr based clads of both processes revealed better metallurgical bonding with the chosen substrate. …”
Get full text
Article -
2580
Anisotropic Behavior of Al1050 through Accumulative Roll Bonding
Published 2021-11-01“…Then, to evaluate sample hardness, the Vickers microhardness test was conducted in the samples’ depth direction, which recorded 39 HV for the annealed piece and 68 HV after the last ARB pass. …”
Get full text
Article