Showing 10,101 - 10,120 results of 10,246 for search '"anode"', query time: 0.14s Refine Results
  1. 10101

    Comparison of the Electrochemical Response of Carbon-Fiber-Reinforced Plastic (CFRP), Glassy Carbon, and Highly Ordered Pyrolytic Graphite (HOPG) in Near-Neutral Aqueous Chloride M... by Stanley Udochukwu Ofoegbu, Mário Guerreiro Silva Ferreira, Helena I. S. Nogueira, Mikhail Zheludkevich

    Published 2023-01-01
    “…Employing the averages of the specific charges (CFRP, 129.52 mC cm<sup>−2</sup>; glassy carbon, 89.95 mC cm<sup>−2</sup>; HOPG, 60.77 mC cm<sup>−2</sup>) passed during 1 h polarization of each of the 3 carbon surfaces at −1000 mV<sub>SCE</sub> in the test media as a ranking criterion, the propensities of the 3 carbon surfaces (CFRP, GC, and HOPG) to support cathodic activities that can lead to anodic metal dissolution on galvanic coupling to metallic materials are ranked thusly; CFRP > GC > HOPG. …”
    Get full text
    Article
  2. 10102

    Antitumor effectiveness of different amounts of electrical charge in Ehrlich and fibrosarcoma Sa-37 tumors by González TR, Pena OG, Salas MF, Bruzón RP, Cabrales LB, Quevedo MS, Ciria HC, López DS, Flores JM

    Published 2004-11-01
    “…In this experiment when the tumor volumes reached 0.35 cm<sup>3</sup>, two anodes and two cathodes were inserted into the base perpendicular to the tumor long axis.…”
    Get full text
    Article
  3. 10103
  4. 10104

    The effect of action observation combined with high-definition transcranial direct current stimulation on motor performance in healthy adults: A randomized controlled trial by Gidon Schwell, Zvi Kozol, David Tarshansky, Moshe Einat, Silvi Frenkel-Toledo, Silvi Frenkel-Toledo

    Published 2023-03-01
    “…We investigated the effect of AO combined with high-definition tDCS (HD-tDCS) targeting the inferior parietal lobe (IPL) and inferior frontal gyrus (IFG), the main aggregates of the human mirror neuron system, on motor performance in healthy adults and compared the immediate vs. 24-h retention test effects (anodal electrodes were placed over these regions of interest). …”
    Get full text
    Article
  5. 10105

    A new biosensing platform based on L-cysteine-capped Fe3O4 nanoparticles embedded in chitosan-MWCNT matrix: Electrochemical kinetic and sensing studies by Tamal Sarkar, Nirmita Dutta, Gorachand Dutta

    Published 2023-12-01
    “…The CS-MWCNT-LCys@Fe3O4 nanocomposite exhibits a twofold enhancement of the peak anodic voltammetric current, and a tenfold decrease in the charge transfer resistance, as compared to the LCys@Fe3O4 nanoparticles. …”
    Get full text
    Article
  6. 10106

    In Situ Raman Investigation of TiO<sub>2</sub> Nanotube Array-Based Ultraviolet Photodetectors: Effects of Nanotube Length by Yanyu Ren, Xiumin Shi, Pengcheng Xia, Shuang Li, Mingyang Lv, Yunxin Wang, Zhu Mao

    Published 2020-04-01
    “…TiO<sub>2</sub> nanotube arrays (TNAs) with tube lengths of 4, 6, and 7 μm were prepared via two-step anodization. Thereafter, ultraviolet (UV) photodetectors (PDs) with Au/TiO<sub>2</sub>/Au structures were prepared using these TNAs with different tube lengths. …”
    Get full text
    Article
  7. 10107

    The effect of temperature on dissipative electron tunneling through Co nanoparticles in HfO2 films by Vladimir D. Krevchik, Mikhail B. Semenov, Dmitriy O. Filatov, Dmitriy A. Antonov

    Published 2023-09-01
    “…Co NPs were formed by local anodic oxidation of the Co sublayer using an AFM probe with subsequent drift of Co ions to the AFM probe, their reduction, and growth of Co NPs near the contact of the AFM probe tip with the surface of the HfO2 film. …”
    Article
  8. 10108

    Safety of One-Stage Atrioventricular Junction Ablation after Pacemaker Implantation for Left Bundle Branch Pacing by Eugene O. Perepeka, Roman A. Sikhnevych

    Published 2024-03-01
    “…The mean intraoperative LBB pacing threshold was 1.71 ± 0.39 V for 0.4 ms, the anodal pacing threshold was 3.25 ± 0.5 V for 0.4 ms (we could demonstrate it in 6 out of 8 patients [75%]). …”
    Get full text
    Article
  9. 10109

    Removal of fluoride and pathogens from water using the combined electrocoagulation-inline-electrolytic disinfection process by Oscar Ezekiel Njau, Philipp Otter, Revocatus Machunda, Anita Rugaika, Kerstin Wydra, Karoli Nicholas Njau

    Published 2023-07-01
    “….; Aluminum and titanium mixed oxide as sacrificial anodes.; Electrolyzed at various current density, flowrates, and supporting electrolyte.; 88% defluoridation (12.3 mg/L) and complete disinfection (19700 CFU/100 mL) meet the WHO standards (<1.5 mg/L and 0 CFU/100 mL, respectively).; Chloride ion break passivation in EC cell and enhance chlorine production in the EC-ECl2 system…”
    Get full text
    Article
  10. 10110

    Chiral Selectors in Voltammetric Sensors Based on Mixed Phenylalanine/Alanine Cu(II) and Zn(II) Complexes by Rufina A. Zilberg, Tatyana V. Berestova, Ruslan R. Gizatov, Yulia B. Teres, Miras N. Galimov, Elena O. Bulysheva

    Published 2022-08-01
    “…Linear relationships between the anodic current and the concentrations of Nap and Prp enantiomers were achieved in the range of 2.5 × 10<sup>−5</sup> to 1.0 × 10<sup>−3</sup> mol L<sup>−1</sup> for GCE/PEC-[Cu(<i>S</i>-Ala)<sub>2</sub>]–[Cu(<i>S</i>-Phe)<sub>2</sub>] and 5.0 × 10<sup>−5</sup> to 1.0 × 10<sup>−3</sup> for GCE/PEC–[Zn(<i>S</i>-Ala)<sub>2</sub>(H<sub>2</sub>O)]–[Zn(<i>S</i>-Phe)<sub>2</sub>(H<sub>2</sub>O)], with detection limits (3 s/m) of 0.30–1.24 μM. …”
    Get full text
    Article
  11. 10111

    Effects of tDCS on Language Recovery in Post-Stroke Aphasia: A Pilot Study Investigating Clinical Parameters and White Matter Change with Diffusion Imaging by Radwa K. Soliman, Chantal M. W. Tax, Noha Abo-Elfetoh, Ahmed A. Karim, Ayda Youssef, Doaa Kamal, Eman M. Khedr

    Published 2021-09-01
    “…Patients received 10 sessions (5/week) bi-hemispheric tDCS treatments over the left affected Broca’s area (anodal electrode) and over the right unaffected Broca’s area (cathodal stimulation). …”
    Get full text
    Article
  12. 10112

    Electrochemical Sensors Based on Single-Wall Carbon Nanotubes in Voltammetric Ascorbic Acid Tests by Natalia V. Ivanova, Elizaveta A. Martynova, Anna I. Vershinina, Maksim V. Lomakin, Galina O. Eremeeva, Olesya R. Gordaya, Sergey D. Shandakov

    Published 2023-12-01
    “…These parameters were selected experimentally to obtain the maximal sensor response to ascorbic acid content. The anodic peak of ascorbic acid in the phosphate buffer electrolyte (pH 6.86) was observed at a potential of +0.2 V. …”
    Get full text
    Article
  13. 10113

    Bifunctional Al-Doped Cobalt Ferrocyanide Nanocube Array for Energy-Saving Hydrogen Production via Urea Electrolysis by Xiafei Gao, Mengyue Gao, Xueping Yu, Xiaoyong Jin, Gang Ni, Juan Peng

    Published 2023-10-01
    “…The very slow anodic oxygen evolution reaction (OER) greatly limits the development of large-scale hydrogen production via water electrolysis. …”
    Get full text
    Article
  14. 10114

    Electrocatalytic Degradation of Phenolic Wastewater Using a Zero-Gap Flow-Through Reactor Coupled with a 3D Ti/RuO<sub>2</sub>-TiO<sub>2</sub>@Pt Electrode by Yunqing Zhu, Kaiyue Wen, Bingqing Li, Yirong Hao, Jianjun Zhou

    Published 2024-03-01
    “…In this study, the performance of a zero-gap flow-through reactor with three-dimensional (3D) porous Ti/RuO<sub>2</sub>-TiO<sub>2</sub>@Pt anodes was systematically investigated for the electrocatalytic oxidation of phenolic wastewater, considering phenol and 4-nitrophenol (4-NP) as the target pollutants. …”
    Get full text
    Article
  15. 10115

    Surface Modification Effect and Electrochemical Performance of LiOH-High Surface Activated Carbon as a Cathode Material in EDLC by Zambaga Otgonbayar, Sunhye Yang, Ick-Jun Kim, Won-Chun Oh

    Published 2021-04-01
    “…The oxidizing agent of LiOH treated high surface area of activated carbon was used for the cathode material for EDLC (electric double layer capacitor) to determine its electrochemical properties and the as-prepared electrode retained excellent performance after 10 cycles and 100 cycles. The anodic and cathodic peak current value and peak segregation of Li-YP80F were better than those of the other two samples, due to the micropore-size and physical properties of the sample. …”
    Get full text
    Article
  16. 10116

    3D Porous Ti<sub>3</sub>C<sub>2</sub> MXene/NiCo-MOF Composites for Enhanced Lithium Storage by Yijun Liu, Ying He, Elif Vargun, Tomas Plachy, Petr Saha, Qilin Cheng

    Published 2020-04-01
    “…To improve Li storage capacity and the structural stability of Ti<sub>3</sub>C<sub>2</sub> MXene-based electrode materials for lithium-ion batteries (LIBs), a facile strategy is developed to construct three-dimensional (3D) hierarchical porous Ti<sub>3</sub>C<sub>2</sub>/bimetal-organic framework (NiCo-MOF) nanoarchitectures as anodes for high-performance LIBs. 2D Ti<sub>3</sub>C<sub>2</sub> nanosheets are coupled with NiCo-MOF nanoflakes induced by hydrogen bonds to form 3D Ti<sub>3</sub>C<sub>2</sub>/NiCo-MOF composite films through vacuum-assisted filtration technology. …”
    Get full text
    Article
  17. 10117

    MnCo<sub>2</sub>O<sub>4</sub>/NiCo<sub>2</sub>O<sub>4</sub>/rGO as a Catalyst Based on Binary Transition Metal Oxide for the Methanol Oxidation Reaction by Mohammad Bagher Askari, Sadegh Azizi, Mohammad Taghi Tourchi Moghadam, Majid Seifi, Seyed Mohammad Rozati, Antonio Di Bartolomeo

    Published 2022-11-01
    “…MN and MNR nanocatalysts, with a maximum current density of 14.58 and 24.76 mA/cm<sup>2</sup> and overvoltage of 0.6 and 0.58 V, as well as cyclic stability of 98.3% and 99.7% (at optimal methanol concentration/scan rate of 20 mV/S), respectively, can be promising and inexpensive options in the field of efficient nanocatalysts for use in methanol fuel cell anodes.…”
    Get full text
    Article
  18. 10118
  19. 10119
  20. 10120