-
841
Monitoring of Interfractional Proton Range Verification and Dosimetric Impact Based on Daily CBCT for Pediatric Patients with Pelvic Tumors
Published 2023-08-01“…The dosimetric impact was due to proton range pullback or overshoot, which led to reduced coverage in CTV Dmin averaging 12.1% and 11.3% in the rescanned and synthetic CT verification plans, respectively; (4) Conclusions: The study demonstrated that synthetic CT generated by deforming the original planning CT to daily CBCT can be used to quantify proton range changes and predict adverse dosimetric scenarios without the need for excessive rescanned CT scans during large interfractional variations in adaptive proton therapy of pediatric pelvic tumors.…”
Get full text
Article -
842
Technical note: Defining cyclotron based clinical scanning proton machines in a FLUKA Monte Carlo system
Published 2017“…<strong>Methods</strong> The described beam is produced at the Provision Proton Therapy Center (Knoxville, Tennessee, USA) using a cyclotron-based IBA Proteus Plus equipment. …”
Journal article -
843
Patient positioning in the proton radiotherapy era
Published 2010-05-01“…<p>Abstract</p> <p>The main hindrance to the diffusion of proton therapy facilities is the high cost for gantry installations. …”
Get full text
Article -
844
-
845
Glioblastoma multiforme - case presentation and literature review
Published 2019-09-01“…Presented case of 75y.o. patient diagnosed with GBM underwent full treatment : surgery and adjuvant proton-therapy. Despite new therapy development, overall survival time of GBM patients is still unacceptable.…”
Get full text
Article -
846
-
847
Novel Monthly Quality Assurance Regimen and 5-Year Analysis Using a Proton Metrology System
Published 2023-10-01“…Purpose: To develop a novel, monthly quality assurance (QA) regimen for a proton therapy system that uses 2 custom phantoms, each housing a commercial scintillator detector and a charge-coupled device camera. …”
Get full text
Article -
848
Design of Low Level RF Control System for 250 MeV Cyclotron
Published 2023-07-01“…A 250 MeV superconducting cyclotron for proton therapy has been developed by the China Institute of Atomic Energy (CIAE). …”
Get full text
Article -
849
Radiation dose and image quality of CT fluoroscopy with partial exposure mode
Published 2020-07-01Get full text
Article -
850
-
851
-
852
High LET-Like Radiation Tracks at the Distal Side of Accelerated Proton Bragg Peak
Published 2021-06-01“…Proton therapy is a type of hadron radiotherapy used for treating solid tumors. …”
Get full text
Article -
853
-
854
Estimation of the risk for radiation-induced liver disease following photon- or proton-beam radiosurgery of liver metastases
Published 2018-10-01“…The clinical implementation of such a model-based approach to select liver metastases patients to proton therapy needs to be made with caution while considering the uncertainties involved in the NTCP estimations.…”
Get full text
Article -
855
Variations in Resources Among Radiation Oncology Residency Programs in the United States
Published 2021-01-01“…Only 19 programs (20%) had in-house proton therapy availability; however, 37 programs (39%) offered proton therapy training via resident rotation at an affiliated institution. …”
Get full text
Article -
856
Feasibility Study of a Proton Irradiation Facility for Radiobiological Measurements at an 18 MeV Cyclotron
Published 2018-11-01“…Measurements of this kind are of interest for proton therapy, since the variation of proton RBE at the distal edge of the Bragg curve may have implications in clinical proton therapy treatments. …”
Get full text
Article -
857
Proton vs photon: A model-based approach to patient selection for reduction of cardiac toxicity in locally advanced lung cancer
Published 2019“…<p><strong>Purpose/Objective:</strong> To use a model-based approach to identify a sub-group of patients with locally advanced lung cancer who would benefit from proton therapy compared to photon therapy for reduction of cardiac toxicity.…”
Journal article -
858
Investigating survival, quality of life and cognition in PROton versus photon therapy for IDH-mutated diffuse grade 2 and 3 GLIOmas (PRO-GLIO): a randomised controlled trial in Nor...
Published 2023-03-01“…Proton therapy enables sparing of non-neoplastic tissue from radiation. …”
Get full text
Article -
859
-
860
Different Approaches in Radiation Therapy
Published 2011-12-01“…Modern treatment technologies including fractionated 3-d conformal radiotherapy, intensity modulated radiation therapy and recently proton therapy are able to precisely cover the target while preserving surrounding tissue,Tumour controls between 80 and in access of 90 % can be achieved. …”
Get full text
Article