-
1041
A Novel NDT Scanning System Based on Line Array Fast Neutron Detector and D-T Neutron Source
Published 2022-07-01“…The fast neutron detection subsystem consists of a polypropylene zinc sulfide scintillator embedded with wavelength-shifting fibers, coupled with a light lens and a scientific CCD camera. …”
Get full text
Article -
1042
Requirements on common solutions to the LSND and MiniBooNE excesses: a post-MicroBooNE study
Published 2022-06-01“…Abstract The strong statistical significance of an observed electron-like event excess in the MiniBooNE (MB) experiment, along with an earlier similar excess seen in the Liquid Scintillator Neutrino Detector (LSND), when interpreted in conjunction with recent MicroBooNE results may have brought us to the cusp of new physics discoveries. …”
Get full text
Article -
1043
Study of a Compton backscattering wall defects detection device using the Monte Carlo method
Published 2023-06-01“…After simulation and comparative analysis, the relevant optimal parameters are obtained: the object is detected using a Cs-137 γ-ray source with an activity of 6 mCi, and a ring detector consisting of four 0.5-inch cube-shaped CsI scintillator detectors is placed at 150° to receive the backscattered photons. …”
Get full text
Article -
1044
Effect of Ultra High Frequency Mobile Phone Radiation on Human Health
Published 2016-05-01“…For radiation dosimetry, we used an ALNOR scintillator that can measure gamma radiation. The simulation was performed by MATLAB software, and data from the International Commission on Non-Ionizing Radiation Protection (ICNIRP) were used to verify the simulation. …”
Get full text
Article -
1045
Gamma rays’ shielding parameters for some Pb-Cu binary alloys
Published 2018-10-01“…Using narrow beam geometry, transmitted photon spectra were recorded with the help of GAMMARAD5 (scintillator detector of NaI(Tl) crystal dimensions 3″ × 3″ having resolution of 6.5% at 662 keV) and radioactive isotopes of Na22 (511 keV), Cs137 (662 keV) and Mn54 (835 keV). …”
Get full text
Article -
1046
Present and Future Contributions of Reactor Experiments to Mass Ordering and Neutrino Oscillation Studies
Published 2020-04-01“…The first example of this kind, the liquid scintillator JUNO experiment, characterized by a very high mass and an unprecedented energy resolution, will soon start data collecting in China. …”
Get full text
Article -
1047
Studies of MCP-PMTs in the miniTimeCube neutrino detector
Published 2018-09-01“…The miniTimeCube detector has 24 8 × 8-anode Photonis MCP-PMT Planacon XP85012, totalling 1536 individual pixels viewing the 2-liter cube of plastic scintillator.…”
Get full text
Article -
1048
Source-detector effective solid angle calculation using MCNP6 code
Published 2021-04-01“…The simulated model consists of a NaI(Tl) scintillator detector and two point isotropic sources (241Am and 137Cs). …”
Get full text
Article -
1049
Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy
Published 2023-06-01“…Based on the detector geometry optimized in the previous study, we constructed a dual-head PG-PET system consisting of a 16 × 16 GAGG scintillator and KETEK SiPM arrays, BaSO4 reflectors, and an 8 × 8 parallel-hole tungsten collimator. …”
Get full text
Article -
1050
X-ray Activated Nanoplatforms for Deep Tissue Photodynamic Therapy
Published 2023-02-01“…Recent advances in the design of nanoparticle-based X-ray scintillators and photosensitizers have enabled hybridization of these moieties into single nanocomposite particles. …”
Get full text
Article -
1051
GAMMA DOSE VALUES OF STRATIGRAPHIC UNITS SURFACED IN BEHRAMKALE (ÇANAKKALE) - ZEYTİNLİ (EDREMİT-BALIKESİR) SECTION OF KAZ MOUNTAINS
Published 2020-02-01“…A SPA-6 plastic scintillation sensor isconnected to the instrument tip to perform the measurement. …”
Get full text
Article -
1052
Design of Monolithic Bi-Layer High-Z PAL-Si Hard X-ray CMOS Image Sensors for Quantum Efficiency Enhancement
Published 2023-08-01“…Furthermore, substituting the high-Z PAL with a lower-Z material—Sn—and alternatively coupling it with a conventional scintillator ma-terial—Lutetium-yttrium oxyorthosilicate (LYSO)—have been compared to demonstrate the most prominent efficacy of monolithic integration of high-Z PAL on Si CIS to detect hard X-rays, paving the way for next-generation high-energy X-ray detection methods.…”
Get full text
Article -
1053
Design and application of gamma radiation monitoring system based on LoRa
Published 2023-09-01“…A wired nuclear radiation monitoring system has the characteristics of complex wiring, a long construction period, high cost, poor mobility, and more difficult troubleshooting.PurposeThis study aims to address the demand for convenient measurement and monitoring of gamma radiation fields.MethodsBased on the LoRa wireless communication technology, a γ radiation monitoring system using silicon photomultiplier (SiPM) tube-scintillator detector was designed. The main functions of the system included data collection from the detector, data processing and transmission using a STM32 single-core processor. …”
Get full text
Article -
1054
Development of neutron time-of-flight measurement system for 1.7-MV tandem proton accelerator with lithium target
Published 2022-02-01“…The nTOF system consists of a 3″ cylindrical NaI(Tl) and four stilbene scintillation detectors. The NaI(Tl) scintillator is placed 50 cm from the Li target to measure the time of beam irradiation on the target, and the stilbene detectors are placed 2 and 2.4 m away to measure nTOF at each location. …”
Get full text
Article -
1055
Reactive Dual Magnetron Sputtering: A Fast Method for Preparing Stoichiometric Microcrystalline ZnWO<sub>4</sub> Thin Films
Published 2021-04-01“…Thin films of ZnWO<sub>4</sub>, a promising photocatalytic and scintillator material, were deposited for the first time using a reactive dual magnetron sputtering procedure. …”
Get full text
Article -
1056
Performance of the MALTA telescope
Published 2023-07-01“…It hosts a dedicated fully configurable trigger system enabling to trigger on coincidence between telescope planes and timing reference from a scintillator. The excellent time resolution performance allows for fast track reconstruction, due to the possibility to retain a low hit multiplicity per event which reduces the combinatorics. …”
Get full text
Article -
1057
Investigation of light ion fusion reactions with plasma discharges
Published 2020“…We detect neutrons from D-D reactions with scintillator-based detectors. For palladium targets, we find neutron yields as a function of cathode voltage that are over 100 times higher than yields expected for bare nuclei fusion at ion energies below 2 keV (center of mass frame). …”
Get full text
Article -
1058
Measurement of differential cross sections for ν μ -Ar charged-current interactions with protons and no pions in the final state with the MicroBooNE detector
Published 2022“…We achieve a significantly lower proton momentum threshold than previous carbon and scintillator-based experiments. Using data collected from a total of approximately 1.6×1020 protons on target, we measure the muon neutrino cross section for the CC0πNp interaction channel in argon at MicroBooNE in the Booster Neutrino Beam which has a mean energy of around 800 MeV. …”
Get full text
Article -
1059
Streaming readout for next generation electron scattering experiments
Published 2022“…We exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. …”
Get full text
Article -
1060