Showing 1,041 - 1,060 results of 2,055 for search '"scintillator"', query time: 0.10s Refine Results
  1. 1041

    A Novel NDT Scanning System Based on Line Array Fast Neutron Detector and D-T Neutron Source by Sheng Wang, Chao Cao, Wei Yin, Yang Wu, Heyong Huo, Yong Sun, Bin Liu, Xin Yang, Rundong Li, Shilei Zhu, Chunlei Wu, Hang Li, Bin Tang

    Published 2022-07-01
    “…The fast neutron detection subsystem consists of a polypropylene zinc sulfide scintillator embedded with wavelength-shifting fibers, coupled with a light lens and a scientific CCD camera. …”
    Get full text
    Article
  2. 1042

    Requirements on common solutions to the LSND and MiniBooNE excesses: a post-MicroBooNE study by Waleed Abdallah, Raj Gandhi, Samiran Roy

    Published 2022-06-01
    “…Abstract The strong statistical significance of an observed electron-like event excess in the MiniBooNE (MB) experiment, along with an earlier similar excess seen in the Liquid Scintillator Neutrino Detector (LSND), when interpreted in conjunction with recent MicroBooNE results may have brought us to the cusp of new physics discoveries. …”
    Get full text
    Article
  3. 1043

    Study of a Compton backscattering wall defects detection device using the Monte Carlo method by Qin Xuan, Yang Jianbo, Du Zhengcong, Xu Jie, Li Rui, Li Hui, Liu Qi

    Published 2023-06-01
    “…After simulation and comparative analysis, the relevant optimal parameters are obtained: the object is detected using a Cs-137 γ-ray source with an activity of 6 mCi, and a ring detector consisting of four 0.5-inch cube-shaped CsI scintillator detectors is placed at 150° to receive the backscattered photons. …”
    Get full text
    Article
  4. 1044

    Effect of Ultra High Frequency Mobile Phone Radiation on Human Health by Mosa Moradi, Nasrollah Naghdi, Hamidreza Hemmati, Majid Asadi-Samani, Mahmoud Bahmani

    Published 2016-05-01
    “…For radiation dosimetry, we used an ALNOR scintillator that can measure gamma radiation. The simulation was performed by MATLAB software, and data from the International Commission on Non-Ionizing Radiation Protection (ICNIRP) were used to verify the simulation. …”
    Get full text
    Article
  5. 1045

    Gamma rays’ shielding parameters for some Pb-Cu binary alloys by Tejbir Singh, Amandeep Kaur, Jeewan Sharma, Parjit S. Singh

    Published 2018-10-01
    “…Using narrow beam geometry, transmitted photon spectra were recorded with the help of GAMMARAD5 (scintillator detector of NaI(Tl) crystal dimensions 3″ × 3″ having resolution of 6.5% at 662 keV) and radioactive isotopes of Na22 (511 keV), Cs137 (662 keV) and Mn54 (835 keV). …”
    Get full text
    Article
  6. 1046

    Present and Future Contributions of Reactor Experiments to Mass Ordering and Neutrino Oscillation Studies by Vito Antonelli, Lino Miramonti, Gioacchino Ranucci

    Published 2020-04-01
    “…The first example of this kind, the liquid scintillator JUNO experiment, characterized by a very high mass and an unprecedented energy resolution, will soon start data collecting in China. …”
    Get full text
    Article
  7. 1047

    Studies of MCP-PMTs in the miniTimeCube neutrino detector by V. A. Li, J. Koblanski, R. Dorrill, M. J. Duvall, K. Engel, G. R. Jocher, J. G. Learned, S. Matsuno, W. F. McDonough, H. P. Mumm, S. Negrashov, K. Nishimura, M. Rosen, M. Sakai, S. M. Usman, G. S. Varner, S. A. Wipperfurth

    Published 2018-09-01
    “…The miniTimeCube detector has 24 8 × 8-anode Photonis MCP-PMT Planacon XP85012, totalling 1536 individual pixels viewing the 2-liter cube of plastic scintillator.…”
    Get full text
    Article
  8. 1048

    Source-detector effective solid angle calculation using MCNP6 code by Roos Sophia de Freitas Dam, Alessandra Galvão Menezes dos Santos, William Luna Salgado, César Marques Salgado

    Published 2021-04-01
    “…The simulated model consists of a NaI(Tl) scintillator detector and two point isotropic sources (241Am and 137Cs). …”
    Get full text
    Article
  9. 1049

    Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy by Bo-Wi Cheon, Hyun Cheol Lee, Sei Hwan You, Hee Seo, Chul Hee Min, Hyun Joon Choi

    Published 2023-06-01
    “…Based on the detector geometry optimized in the previous study, we constructed a dual-head PG-PET system consisting of a 16 × 16 GAGG scintillator and KETEK SiPM arrays, BaSO4 reflectors, and an 8 × 8 parallel-hole tungsten collimator. …”
    Get full text
    Article
  10. 1050

    X-ray Activated Nanoplatforms for Deep Tissue Photodynamic Therapy by Jeffrey S. Souris, Lara Leoni, Hannah J. Zhang, Ariel Pan, Eve Tanios, Hsiu-Ming Tsai, Irina V. Balyasnikova, Marc Bissonnette, Chin-Tu Chen

    Published 2023-02-01
    “…Recent advances in the design of nanoparticle-based X-ray scintillators and photosensitizers have enabled hybridization of these moieties into single nanocomposite particles. …”
    Get full text
    Article
  11. 1051

    GAMMA DOSE VALUES OF STRATIGRAPHIC UNITS SURFACED IN BEHRAMKALE (ÇANAKKALE) - ZEYTİNLİ (EDREMİT-BALIKESİR) SECTION OF KAZ MOUNTAINS by Zeki Ünal YÜMÜN, Erol KAM, Melike ÖNCE

    Published 2020-02-01
    “…A SPA-6 plastic scintillation sensor isconnected to the instrument tip to perform the measurement. …”
    Get full text
    Article
  12. 1052

    Design of Monolithic Bi-Layer High-Z PAL-Si Hard X-ray CMOS Image Sensors for Quantum Efficiency Enhancement by Eldred Lee, Kevin D. Larkin, Xin Yue, Zhehui Wang, Eric R. Fossum, Jifeng Liu

    Published 2023-08-01
    “…Furthermore, substituting the high-Z PAL with a lower-Z material—Sn—and alternatively coupling it with a conventional scintillator ma-terial—Lutetium-yttrium oxyorthosilicate (LYSO)—have been compared to demonstrate the most prominent efficacy of monolithic integration of high-Z PAL on Si CIS to detect hard X-rays, paving the way for next-generation high-energy X-ray detection methods.…”
    Get full text
    Article
  13. 1053

    Design and application of gamma radiation monitoring system based on LoRa by ZHANG Di, CHENG Maosong, DAI Zhimin, SHI Chenglong

    Published 2023-09-01
    “…A wired nuclear radiation monitoring system has the characteristics of complex wiring, a long construction period, high cost, poor mobility, and more difficult troubleshooting.PurposeThis study aims to address the demand for convenient measurement and monitoring of gamma radiation fields.MethodsBased on the LoRa wireless communication technology, a γ radiation monitoring system using silicon photomultiplier (SiPM) tube-scintillator detector was designed. The main functions of the system included data collection from the detector, data processing and transmission using a STM32 single-core processor. …”
    Get full text
    Article
  14. 1054

    Development of neutron time-of-flight measurement system for 1.7-MV tandem proton accelerator with lithium target by Soobin Lim, Donghwan Kim, Jin-Goo Kang, Jeong-Jeung Dang, Pilsoo Lee, Geehyun Kim, Kyoung-Jae Chung, Y.S. Hwang

    Published 2022-02-01
    “…The nTOF system consists of a 3″ cylindrical NaI(Tl) and four stilbene scintillation detectors. The NaI(Tl) scintillator is placed 50 cm from the Li target to measure the time of beam irradiation on the target, and the stilbene detectors are placed 2 and 2.4 m away to measure nTOF at each location. …”
    Get full text
    Article
  15. 1055

    Reactive Dual Magnetron Sputtering: A Fast Method for Preparing Stoichiometric Microcrystalline ZnWO<sub>4</sub> Thin Films by Yannick Hermans, Faraz Mehmood, Kerstin Lakus-Wollny, Jan P. Hofmann, Thomas Mayer, Wolfram Jaegermann

    Published 2021-04-01
    “…Thin films of ZnWO<sub>4</sub>, a promising photocatalytic and scintillator material, were deposited for the first time using a reactive dual magnetron sputtering procedure. …”
    Get full text
    Article
  16. 1056

    Performance of the MALTA telescope by Milou van Rijnbach, Giuliano Gustavino, Phil Allport, Ignacio Asensi Tortajada, Dumitru Vlad Berlea, Daniela Bortoletto, Craig Buttar, Edoardo Charbon, Florian Dachs, Valerio Dao, Dominik Dobrijevic, Leyre Flores Sanz de Acedo, Andrea Gabrielli, Martin Gazi, Laura Gonella, Vicente Gonzalez, Stefan Guidon, Matt LeBlanc, Heinz Pernegger, Francesco Piro, Petra Riedler, Heidi Sandaker, Abhishek Sharma, Carlos Solans Sanchez, Walter Snoeys, Tomislav Suligoj, Marcos Vazquez Nunez, Julian Weick, Steven Worm, Abdelhak M. Zoubir

    Published 2023-07-01
    “…It hosts a dedicated fully configurable trigger system enabling to trigger on coincidence between telescope planes and timing reference from a scintillator. The excellent time resolution performance allows for fast track reconstruction, due to the possibility to retain a low hit multiplicity per event which reduces the combinatorics. …”
    Get full text
    Article
  17. 1057

    Investigation of light ion fusion reactions with plasma discharges by Chiang, Y.-M.

    Published 2020
    “…We detect neutrons from D-D reactions with scintillator-based detectors. For palladium targets, we find neutron yields as a function of cathode voltage that are over 100 times higher than yields expected for bare nuclei fusion at ion energies below 2 keV (center of mass frame). …”
    Get full text
    Article
  18. 1058

    Measurement of differential cross sections for ν μ -Ar charged-current interactions with protons and no pions in the final state with the MicroBooNE detector by Conrad, Janet

    Published 2022
    “…We achieve a significantly lower proton momentum threshold than previous carbon and scintillator-based experiments. Using data collected from a total of approximately 1.6×1020 protons on target, we measure the muon neutrino cross section for the CC0πNp interaction channel in argon at MicroBooNE in the Booster Neutrino Beam which has a mean energy of around 800 MeV. …”
    Get full text
    Article
  19. 1059

    Streaming readout for next generation electron scattering experiments by Ameli, Fabrizio, Battaglieri, Marco, Berdnikov, Vladimir V., Bondí, Mariangela, Boyarinov, Sergey, Brei, Nathan, Celentano, Andrea, Cappelli, Laura, Chiarusi, Tommaso, De Vita, Raffaella, Fanelli, Cristiano, Gyurjyan, Vardan, Lawrence, David, Moran, Patrick, Musico, Paolo, Pellegrino, Carmelo, Pilloni, Alessandro, Raydo, Ben, Timmer, Carl, Ungaro, Maurizio

    Published 2022
    “…We exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. …”
    Get full text
    Article
  20. 1060