Showing 1,641 - 1,660 results of 2,055 for search '"scintillator"', query time: 0.09s Refine Results
  1. 1641

    Assessment of nuclear radiation pollution in uranium mining-impacted soil by Raad Obid Hussein Houmady

    Published 2019-02-01
    “…To measure the specific activity, twenty five surface soil samples were collected, prepared and analyzed by using gamma- ray spectrometer based on high counting efficiency NaI(Tl) scintillation detector. The results showed that the specific activities in Bq/kg are 37.31 to 1112.47 with mean of 268.16, 0.28 to 18.57 with mean of 6.68 and 132.25 to 678.33 with mean of 277.49 for 238U, 232Th and 40K respectively. …”
    Get full text
    Article
  2. 1642

    NATURALLY OCCURRING RADIONUCLIDES (40K, 226Ra, 232Th) IN THE ENVIRONMENT (VERKHNEKAMSKOE DEPOSIT OF POTASSIUM-MAGNESIUM SALTS) by Roman D. Perevoshchikov

    Published 2022-03-01
    “…Measurements of specific activity of natural radionuclides (40K, 226Ra, 232Th) in samples of soils and bottom sediments were performed using MULTIRAD scintillation gamma spectrometer MKS-01A (Russia). Gamma-spectra were processed using programs included in the Progress package. …”
    Get full text
    Article
  3. 1643
  4. 1644

    PENENTUAN UMUR PELAPUKAN TANAH DENGAN RADIOISOTOP 14C MENGGUNAKAN METODE ABSORPSI CO2 by , VEGA ARMAN YAHYA, , Ir. Agus Budhie Wijatna, M.Si.

    Published 2013
    “…The measurement of the number of soil sample activity used Liquid Scintillation Counter (LSC) detector Tri-Carb 2910 TR type. …”
    Thesis
  5. 1645

    Antidiabetic activities of Cinnamomum zeylanicum and Tinospora crispa on adipocytes by Bakhtiar, M. Taher, Mohamed Amiroudine, Mohamed Zaffar Ali, Solachuddin Jauhari, Arief Ichwan, Kaderi, Mohd Arifin, Darnis, Deny Susanti

    Published 2011
    “…Glucose uptake activity was investigated in differentiated adipocytes using a radioactive-labelled glucose by Liquid Scintillation Counter. The activities in the glucose uptake between untreated and treated cells showed that both plants were statistically significant compared metformin (1 mM), but not significant compared to sodium orthovanadate (5 mM). …”
    Get full text
    Proceeding Paper
  6. 1646

    Development of method for simultaneous measurement of gross alpha and beta in aqueous environmental samples / Masitah Alias by Alias, Masitah

    Published 2014
    “…Alternatively, liquid scintillation counting (LSC) offers a better solution, since the latest model of LSC offer simultaneous counting of gross alpha and beta. …”
    Get full text
    Thesis
  7. 1647

    Adaptive biological networks by Fricker, M, Boddy, L, Nakagaki, T, Bebber, D

    Published 2009
    “…Experimentally, nutrient movement can be mapped using radio-tracers and scintillation imaging, and shows more complex transport dynamics, with synchronized oscillations and switching between different pre-existing routes. …”
    Book section
  8. 1648

    Imaging of long-distance alpha-aminoisobutyric acid translocation dynamics during resource capture by Serpula lacrymans. by Tlalka, M, Fricker, M, Watkinson, S

    Published 2008
    “…The dynamics of translocation of subtoxic amounts of [1-(14)C]AIB ([(14)C]AIB) were mapped by photon-counting scintillation imaging in conjunction with destructive harvest to establish the velocity, direction, and rate of translocation and the extent of [(14)C]AIB reallocation accompanying the invasion of fresh wood. …”
    Journal article
  9. 1649

    Systematic effects in LOFAR data: A unified calibration strategy by De Gasperin, F, Dijkema, TJ, Drabent, A, Mevius, M, Rafferty, D, Van Weeren, R, Brueggen, M, Callingham, JR, Emig, KL, Heald, G, Intema, HT, Morabito, LK, Offringa, AR, Oonk, R, Orru, E, Rottgering, H, Sabater, J, Shimwell, T, Shulevski, A, Williams, W

    Published 2019
    “…We were able to isolate and correct for the effects of clock drift, polarisation misalignment, ionospheric delay, Faraday rotation, ionospheric scintillation, beam shape, and bandpass. The designed calibration strategy produced the deepest image to date at 54 MHz. …”
    Journal article
  10. 1650

    Stress strain behaviour of a cohesive soil deposited under water by Been, K, K. Been

    Published 1980
    “…The density measuring technique developed, using an X-ray source and a scintillation counter, is described in some detail. An experiment consists of monitoring the sedimentation, form an initially uniform suspension, of an inorganic clayey silt in a 102 mm I.D. column. …”
    Thesis
  11. 1651

    Scattering analysis of LOFAR pulsar observations by Geyer, M, Karastergiou, A, Kondratiev, V, Zagkouris, K, Kramer, M, Stappers, B, Grießmeier, J, Hessels, J, Michilli, D, Pilia, M, Sobey, C

    Published 2017
    “…Very long baseline interferometry, and observations of the scattering and scintillation properties of these sources at higher frequencies, will provide further evidence.…”
    Journal article
  12. 1652

    A pilot survey for transients and variables with the Australian Square Kilometre Array Pathfinder by Bhandari, S, Bannister, K, Murphy, T, Bell, M, Raja, W, Marvil, J, Hancock, P, Whiting, M, Flynn, C, Collier, J, Kaplan, D, Allison, J, Anderson, C, Heywood, I, Hotan, A, Hunstead, R, Lee-Waddell, K, Madrid, J, McConnell, D, Popping, A, Rhee, J, Sadler, E, Voronkov, M

    Published 2018
    “…They are identified to be compact active galactic nucleus (AGN)/quasars or galaxies hosting an AGN, whose variability is consistent with refractive interstellar scintillation. We also detect a highly variable source with modulation index m > 0.5 over atime intervalof a decade between the Sydney University Molonglo Sky Survey (SUMSS) and our latest ASKAP observations. …”
    Journal article
  13. 1653

    Measurement of radon-222 and radium-226 in well water of Kelantan by Sidi Ahmad, Nurul Ashikin

    Published 2013
    “…The levels of 222Rn and 226Ra dissolved in well water were measured using the liquid scintillation counting technique. 222Rn activity concentrations were found within the range of 0.0491 to 4.3127 Bq/l for both unfiltered and filtered samples. …”
    Get full text
    Thesis
  14. 1654

    Low-noise fast-response readout circuit to improve coincidence time resolution by Jiwoong Jung, Yong Choi, Seunghun Back, Jin Ho Jung, Sangwon Lee, Yeonkyeong Kim

    Published 2024-04-01
    “…Time-of-flight (TOF) PET detectors with fast-rise-time scintillators and fast-single photon time resolution silicon photomultiplier (SiPM) have been developed to improve the coincidence timing resolution (CTR) to sub-100 ps. …”
    Get full text
    Article
  15. 1655

    Tritium contents in drinking and surface seawaters before the nuclear power plant planned in Sinop (Türkiye) and their radiological risks on human population by Serdar Dizman, Feyza Zeynep Aşık, Ali Erdem Özçelik, Recep Keser, Filiz Korkmaz Görür

    Published 2023-12-01
    “…Tritium concentrations in the collected water samples were measured by the liquid scintillation counter. The minimum detectable activity for the method used was found to be 1.48 Bq/L. …”
    Get full text
    Article
  16. 1656

    A Novel Method for Spectrometry Based on Imaging Systems by Rita Falconi, Stefania Sorbino, Roberto Pani, Luca Indovina

    Published 2022-02-01
    “…<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mi>γ</mi></semantics></math></inline-formula>-ray spectrometry is a well-known technique in environmental radioactivity measurements where easily handled systems are needed. Scintillators coupled to a photomultiplier tube (PMT), are typically favoured over solid-state detectors as mobile spectrometers. …”
    Get full text
    Article
  17. 1657

    Photometric Defocus Observations of Transiting Extrasolar Planets by Tobias C. Hinse, Wonyong Han, Joh-Na Yoon, Joh-Na Yoon, Yong-Gi Kim, Chun-Hwey Kim

    Published 2015-03-01
    “…Furthermore, a longer exposure time helps reduce the effect of scintillation noise which otherwise has a significant effect for small-aperture telescopes operated in in-focus mode. …”
    Get full text
    Article
  18. 1658

    Reconstruction of Compton Edges in Plastic Gamma Spectra Using Deep Autoencoder by Byoungil Jeon, Youhan Lee, Myungkook Moon, Jongyul Kim, Gyuseong Cho

    Published 2020-05-01
    “…Plastic scintillation detectors are widely utilized in radiation measurement because of their unique characteristics. …”
    Get full text
    Article
  19. 1659

    Conductive natural and waste rubbers composites-loaded with lead powder as environmental flexible gamma radiation shielding material by Ahmed M El-Khatib, A S Doma, Mohamed S Badawi, Asmaa E Abu-Rayan, N S Aly, Jamila S Alzahrani, Mahmoud I Abbas

    Published 2020-01-01
    “…Gamma attenuation study was carried out using 3″ × 3″ NaI (Tl) (scintillation detector) gamma-ray spectrometer for (Cs-137), (Co-60), (Ba-133), and (Eu-152). …”
    Get full text
    Article
  20. 1660

    Atmospheric Effects on the Performance of Geosynchronous Orbit SAR Systems by Hu Cheng, Dong Xichao, Li Yuanhao

    Published 2018-08-01
    “…Considering the influence of random disturbances such as tropospheric turbulence and ionospheric scintillation in atmosphere, a quantitative analysis model is established based on a power law power spectrum model using the atmospheric disturbance and imaging quality parameters. …”
    Get full text
    Article