Showing 1 - 20 results of 305 for search '"serf"', query time: 0.22s Refine Results
  1. 1
  2. 2

    SERF Protein Is a Direct Modifier of Amyloid Fiber Assembly by S. Fabio Falsone, N. Helge Meyer, Evelyne Schrank, Gerd Leitinger, Chi L.L. Pham, Michelle T. Fodero-Tavoletti, Mats Holmberg, Martin Dulle, Benjamin Scicluna, Bernd Gesslbauer, Hanna-Marie Rückert, Gabriel E. Wagner, David A. Merle, Ellen A. Nollen, Andreas J. Kungl, Andrew F. Hill, Roberto Cappai, Klaus Zangger

    Published 2012-08-01
    “…It was recently shown that a class of evolutionary conserved proteins, called MOAG-4/SERF, profoundly alter amyloid toxicity via an autonomous but yet unexplained mode. …”
    Get full text
    Article
  3. 3

    Suppression of thermal coupling noise in the SERF atomic co-magnetometer by Jiasen Ruan, Lihong Duan, Yang Fu, Lv Yang, Wenfeng Fan, Xinxiu Zhou, Wei Quan

    Published 2023-10-01
    Subjects: “…Spin-exchange relaxation-free (SERF) co-magnetometer…”
    Get full text
    Article
  4. 4

    Metasurface-integrated elliptically polarized laser-pumped SERF magnetometers by Zihua Liang, Jinsheng Hu, Peng Zhou, Lu Liu, Gen Hu, Ankang Wang, Mao Ye

    Published 2024-07-01
    “…Abstract The emergence of biomagnetism imaging has led to the development of ultrasensitive and compact spin-exchange relaxation-free (SERF) atomic magnetometers that promise high-resolution magnetocardiography (MCG) and magnetoencephalography (MEG). …”
    Get full text
    Article
  5. 5
  6. 6

    Constraints on axion-like dark matter from a SERF comagnetometer by Itay M. Bloch, Roy Shaham, Yonit Hochberg, Eric Kuflik, Tomer Volansky, Or Katz

    Published 2023-09-01
    “…The detector uses nuclei of noble-gas and alkali-metal atoms and operates in the Spin-Exchange Relaxation-Free (SERF) regime, achieving high sensitivity to axion-like dark matter fields. …”
    Get full text
    Article
  7. 7
  8. 8

    Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell by Yintao Ma, Yao Chen, Mingzhi Yu, Yanbin Wang, Shun Lu, Ju Guo, Guoxi Luo, Libo Zhao, Ping Yang, Qijing Lin, Zhuangde Jiang

    Published 2024-08-01
    “…In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. …”
    Get full text
    Article
  9. 9
  10. 10
  11. 11
  12. 12

    Serf Thinking of Russian Post-Reform Society and Leveling and Reefficient Community (to Problem Statement) by M A Davidov

    Published 2013-12-01
    “…The author considers that in a basis of this phenomenon the not overcome serf consciousness of the Russian society lay.…”
    Get full text
    Article
  13. 13
  14. 14

    Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer by Jiajie Li, Ying Liu, Renjie Li, Qian Cao, Tianwei Zhou, Yueyang Zhai

    Published 2024-01-01
    “…Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. …”
    Get full text
    Article
  15. 15

    A new wearable multichannel magnetocardiogram system with a SERF atomic magnetometer array by Yanfei Yang, Mingzhu Xu, Aimin Liang, Yan Yin, Xin Ma, Yang Gao, Xiaolin Ning

    Published 2021-03-01
    “…Abstract In this study, a wearable multichannel human magnetocardiogram (MCG) system based on a spin exchange relaxation-free regime (SERF) magnetometer array is developed. The MCG system consists of a magnetically shielded device, a wearable SERF magnetometer array, and a computer for data acquisition and processing. …”
    Get full text
    Article
  16. 16
  17. 17

    Structural fuzziness of the RNA-organizing protein SERF determines a toxic gain-of-interaction by Meyer, N, Dellago, H, Tam-Amersdorfer, C, Merle, D, Parlato, R, Gesslbauer, B, Almer, J, Gschwandtner, M, Leon, A, Franzmann, T, Grillari, J, Kungl, A, Zangger, K, Falsone, S

    Published 2019
    “…The absence of primary or secondary structure discriminants results in SERF1a being unable to select between nucleic acid and amyloidogenic protein, leading the pro-amyloid aSyn:SERF1a interaction to prevail in the cytosol under conditions of cellular stress. …”
    Journal article
  18. 18
  19. 19
  20. 20

    A p.Val412Serfs pathogenic variant associated with Wolfram-like syndrome and leukodystrophy by Ayca Kocaaga, Sevgi Yimenicioglu, Murat Bayav

    Published 2023-01-01
    “…The heterozygous frame-shift (c.1230_1233delCTCT; p.Val412Serfs) mutation in the WFS1 gene. This heterozygous pathogenic variant in the WFS1 gene was identified in both the father and grandmother. …”
    Get full text
    Article