-
1
DEVELOPMENT OF THE ZEUS CENTRAL TRACKING DETECTOR
Published 1989“…The design concept and development of the ZEUS central tracking detector is described. This is a cylindrical drift chamber designed for track reconstruction, electron identification and event triggering in a high-crossing-rate, high-magnetic-field environment. © 1989.…”
Conference item -
2
-
3
Nuclear track detectors : design, methods and applications /
Published 2010Subjects: “…Nuclear track detectors…”
-
4
Overview of CMOS Sensors for Future Tracking Detectors
Published 2020-11-01“…Depleted Complementary Metal-Oxide-Semiconductor (CMOS) sensors are emerging as one of the main candidate technologies for future tracking detectors in high luminosity colliders. Their capability of integrating the sensing diode into the CMOS wafer hosting the front-end electronics allows for reduced noise and higher signal sensitivity, due to the direct collection of the sensor signal by the readout electronics. …”
Get full text
Article -
5
THE DESIGN AND CONSTRUCTION OF THE ZEUS CENTRAL TRACKING DETECTOR
Published 1994“…The mechanical, electrical and electronic design and construction of the ZEUS central tracking detector are described, together with the chamber monitoring and environmental control. …”
Journal article -
6
THE PERFORMANCE OF THE FADC SYSTEM FOR THE ZEUS CENTRAL TRACKING DETECTOR
Published 1993“…The Central Tracking Detector of the ZEUS experiment uses a Flash Analogue to Digital Converter (FADC) read-out system to measure the arrival time of ionisation at sense wires as well as the charge deposited. …”
Conference item -
7
Performance of the FADC system for the ZEUS central tracking detector
Published 1994“…The Central Tracking Detector (CTD) of the ZEUS experiment uses a Flash Analogue to Digital Converter (FADC) readout system to measure the arrival time of ionisation at sense wires as well as the charge deposited. …”
Journal article -
8
THE PERFORMANCE OF THE FADC SYSTEM FOR THE ZEUS CENTRAL TRACKING DETECTOR
Published 1994Conference item -
9
CR-39 plastic nuclear track detectors in physics research /
Published c201Subjects: “…Nuclear track detectors…”
-
10
Optimization of methodology with solid state nuclear track detector (SSNTD)
Published 2021-04-01“… The present study aims to optimize the passive methodology with Solid state Nuclear Track Detector (SSNTD) called the sealed can technique in the physics laboratory of the Federal Institute of Paraná - Telêmaco Borba Campus. …”
Get full text
Article -
11
Configuration of the parameters for scanner-based track detector evaluation system
Published 2020-06-01“…In this study, selection of the applied track detectors and setting of the etching conditions have been carried out. …”
Get full text
Article -
12
THE DESIGN, STATUS AND PERFORMANCE OF THE ZEUS CENTRAL TRACKING DETECTOR ELECTRONICS
Published 1992Conference item -
13
First and second level triggers for the SDC silicon tracking detector
Published 1992Journal article -
14
2ND LEVEL TRIGGER FOR THE SDC SILICON TRACKING DETECTOR
Published 1995“…The design of the second level trigger for the inner silicon tracking detector of the SDC experiment at the Superconducting Super Collider (SSC) is outlined. …”
Conference item -
15
Radon measurements with CR-39 track detectors at specific locations in Turkey
Published 2004-01-01“…Indoor radon concentration levels at three sites in Turkey were measured using CR-39 solid state nuclear track detectors. The annual mean of radon concentration was estimated on the basis of four quarter measurements at specific locations in Turkey. …”
Get full text
Article -
16
THE INVESTIGATION OF POSSIBILITY SPECTROMETRY α-PARTICLES BY SOLID-BODY TRACKING DETECTORS
Published 2010-09-01“…A precise method of measuring the activity of alpha-sources of energy lines by using solid-track detectors is developed. The optimum conditions of extraction stages of registered information are defined. …”
Get full text
Article -
17
Effect of annealing on etch rate of Nuclear Track Detector CR-39
Published 2023-09-01Get full text
Article -
18
The Design and Performance of the ZEUS Central Tracking Detector z-by-Timing System
Published 1997“…The ZEUS Central Tracking Detector utilizes a time difference measurement to provide a fast determination of the z-coordinate of each hit. …”
Journal article -
19
Effect of Ultraviolet Radiation and Alpha-particles on Nuclear Track Detector CR-39
Published 2023-06-01Get full text
Article -
20
He–Ne laser induced changes to CN-85 polymer track detector
Published 2016-10-01“…In this work, the induced changes in cellulose nitrate (CN-85) polymer track detector have been investigated. CN-85 samples were irradiated with He–Ne laser at different fluences. …”
Get full text
Article