Search alternatives:
"tomographics" » "demographics" (Expand Search), "topographies" (Expand Search), "homographies" (Expand Search), "demographicss" (Expand Search), "ethnographics" (Expand Search)
"tomographic" » "demographic" (Expand Search), "demographics" (Expand Search), "ethnographic" (Expand Search)
"topographic" » "topography" (Expand Search), "ethnographic" (Expand Search), "photographic" (Expand Search)
"tomographics" » "demographics" (Expand Search), "topographies" (Expand Search), "homographies" (Expand Search), "demographicss" (Expand Search), "ethnographics" (Expand Search)
"tomographic" » "demographic" (Expand Search), "demographics" (Expand Search), "ethnographic" (Expand Search)
"topographic" » "topography" (Expand Search), "ethnographic" (Expand Search), "photographic" (Expand Search)
-
41
Adjoint-state traveltime tomography for azimuthally anisotropic media in spherical coordinates
Published 2023“…This method is applicable for large-scale tomography, and its performance is verified by a synthetic checkerboard test and a practical seismic tomographic inversion in central California near Parkfield.…”
Get full text
Journal Article -
42
Quantitative analysis of coronary artery from computed tomography angiography images
Published 2016“…An automated, robust and efficient method to approach most Computed Tomography Angiography (CTA) images is still in demand due to the intrinsic ill-posedness and the external stenosis quantification difficulties such as manual measurement, low contrast and huge processing time, which motivates the studies in this thesis. …”
Get full text
Thesis -
43
Quantitative imaging using ultrasonic tomography based on full waveform inversion
Published 2018“…Based on this concept, ultrasonic tomography provides a promising alternative for defects/inclusions diagnosis. …”
Get full text
Thesis -
44
Characterization on three-dimensional trajectory of disk-like gold-nickel-platinum nanomotor using digital holographic imaging
Published 2019“…In addition, the holographic images are for the first time used to reconstruct the instantaneously three‐dimensional (3D) location and trajectory of the nanomotor.…”
Get full text
Get full text
Journal Article -
45
Optical diffraction tomography for assessing single cell models in angular light scattering
Published 2024“…We investigate the validity of these assumptions using 3D refractive index (RI) tomograms measured via optical diffraction tomography (ODT). We compute the angular scattering on digitally manipulated tomograms with increasingly strong model assumptions, including RI-matched immersion media, homogeneous cytosol, and spherical organelles. …”
Get full text
Article -
46
-
47
An efficient image formation algorithm for real-time linear-array photoacoustic tomography
Published 2019Subjects: “…Photoacoustic Tomography…”
Get full text
Get full text
Conference Paper -
48
Multi-angle data acquisition to compensate transducer finite size in photoacoustic tomography
Published 2022Subjects: Get full text
Journal Article -
49
Single-input polarization-sensitive optical coherence tomography through a catheter
Published 2023“…Intravascular polarimetry with catheter-based polarization-sensitive optical coherence tomography (PS-OCT) complements the high-resolution structural tomograms of OCT with morphological contrast available through polarimetry. …”
Get full text
Journal Article -
50
Limited-view ultrasonic guided wave tomography using an adaptive regularization method
Published 2017“…Ultrasonic guided waves are useful to assess the integrity of a structure from a remote location. Recently, tomography techniques have been developed to quantitatively estimate the thickness map of plate-like structures based on the dispersion characteristics of guided waves. …”
Get full text
Get full text
Journal Article -
51
Modified delay-and-sum reconstruction algorithm to improve tangential resolution in photoacoustic tomography
Published 2018“…In photoacoustic/optoacoustic tomography (PAT/OAT) for a circular scanning geometry, the axial/radial resolution is not variant spatially and also do not depend on the ultrasound transducer (UST) aperture. …”
Get full text
Get full text
Conference Paper -
52
Depth-of-focus extension in optical coherence tomography via multiple aperture synthesis
Published 2018Subjects: Get full text
Get full text
Journal Article -
53
Spectral domain optical coherence tomography with extended depth-of-focus by aperture synthesis
Published 2018Subjects: Get full text
Get full text
Conference Paper -
54
Automatic segmentation of the choroid in enhanced depth imaging optical coherence tomography images
Published 2013“…Enhanced Depth Imaging (EDI) optical coherence tomography (OCT) provides high-definition cross-sectional images of the choroid in vivo, and hence is used in many clinical studies. …”
Get full text
Get full text
Journal Article -
55
Quantitative measurement of displacement in photopolymer layers during holographic recording using phase shifting electronic speckle pattern interferometry
Published 2016“…The aim of this study is to determine the displacement profile due to shrinkage in acrylamide-based photopolymer layer during holographic recording. Using phase shifting electronic speckle pattern interferometry the displacement at each pixel in the image of the object is measured by phase shifting technique so that a complete displacement profile of the object can be obtained. …”
Get full text
Get full text
Conference Paper -
56
Regulation of lipid droplets in live preadipocytes using optical diffraction tomography and Raman spectroscopy
Published 2020“…In this paper, we study the effects of fatty acid stimulation and cell starvation on lipid droplets using optical diffraction tomography and Raman spectroscopy by measuring size, refractive index, volume, dry mass and degree of unsaturation. …”
Get full text
Journal Article -
57
Effect of hyperoxia and hypoxia on retinal vascular parameters assessed with optical coherence tomography angiography
Published 2022“…To investigate the response of the superficial and deep capillary plexuses to hyperoxia and hypoxia using optical coherence tomography angiography (OCT-A) and retinal vessel analyzer.…”
Get full text
Journal Article -
58
In vivo positron emission tomography imaging of mitochondrial abnormalities in a mouse model of tauopathy
Published 2023“…Here we used a recently developed positron emission tomography (PET) probe targeting mitochondrial complex I (MC-I), 18F-BCPP-EF, to non-invasively visualize mitochondrial abnormalities in the brains of tau transgenic mice (rTg4510 TauTg). …”
Get full text
Journal Article -
59
X-Ray Computed Tomography Study of the Microstructure of Superconducting MgB 2 Bulks
Published 2025“…In this work, high-resolution laboratory X-ray computed tomography (XCT) has been used to investigate the microstructure of MgB2 bulks in three dimensions. …”
Journal article -
60
Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system
Published 2017Subjects: “…Photoacoustic tomography…”
Get full text
Get full text
Journal Article