Showing 181 - 200 results of 236 for search '((("topographic" OR "holographic") OR "topographics") OR ("tomographic" OR "tomography"))', query time: 0.16s Refine Results
  1. 181

    Eikonal equation-based earthquake location by Li, Xiaoyan

    Published 2022
    “…We also use fast marching method by grid searching and traveltime adjoint tomography method to improve the accuracy and correctness of the earthquake location.…”
    Get full text
    Thesis-Master by Research
  2. 182

    Membrane filtration of manganese (II) remediated-microalgae: manganese (II) removal, extracellular organic matter, and membrane fouling by Sim, Lee Nuang, Ho, Jia Shin, Khaswan, Nurshazwani Binte, Wu, Bing, Chong, Tzyy Haur

    Published 2022
    “…The optical coherence tomography (OCT) analysis revealed that the specific volume of cake layer increased gradually over time, however, the irreversible fouling was predominant and associated the presence of building blocks in soluble organics.…”
    Get full text
    Journal Article
  3. 183

    Formation of the postmitotic nuclear envelope from extended ER cisternae precedes nuclear pore assembly by Lu, Lei, Ladinsky, Mark S., Kirchhausen, Tomas.

    Published 2011
    “…Using live-cell imaging and electron microscope tomography, we find that the mitotic assembly of the nuclear envelope primarily originates from ER cisternae. …”
    Get full text
    Get full text
    Journal Article
  4. 184

    New methods in 18F-fluorination and fluoroalkylation by Ford, J

    Published 2024
    “…<p><strong>Chapter 1</strong> (<em>Introduction</em>) summarises the key concepts surrounding Positron Emission Tomography (PET) imaging, including the underlying physical principles and its applications and the use of fluorine-18 as a PET radioisotope. …”
    Thesis
  5. 185

    Novel material composites for dielectric elastomer actuators by Ankit

    Published 2020
    “…A new device architecture for dielectric elastomer actuators, capable of producing on-demand surface texture change and local topographic features, is demonstrated. Owing to its unique architecture, a highly transparent, flexible and integrable configuration of the device is showed. …”
    Get full text
    Thesis-Doctor of Philosophy
  6. 186

    Edible Bird's Nest treatment effects on subchondral bone and articular cartilage changes and synovial fluid proteome profiles in an osteoarthritis rabbit model by Syed Sulaiman, Sharifah Zakiah

    Published 2022
    “…The joints were subjected to micro-computed tomographic (micro-CT) analysis and histological evaluation. …”
    Get full text
    Thesis
  7. 187

    Computational modeling of low-density lipoprotein accumulation at the carotid artery bifurcation after stenting by Nasrul Hadi, Johari, Menichini, Claudia, Hamady, Mohamad S., Xu, Xiaoyun

    Published 2023
    “…Anatomically realistic geometric models of the carotid bifurcation were built based on pre- and post-stent computed tomography (CT) scans. The influence of stent design was investigated by virtually deploying two different types of stents (open- and closed-cell stents) into the same carotid bifurcation model. …”
    Get full text
    Article
  8. 188
  9. 189

    Comparative analysis of changes in retinal layer thickness following femtosecond laser-assisted cataract surgery and conventional cataract surgery by Surl, Dongheon, Kim, Seungmin, Kim, Sangyeop, Kim, Tae-Im, Seo, Kyoung Yul, Jun, Ikhyun

    Published 2024
    “…Methods This study included 113 unrelated Korean patients with age-related cataract who underwent CCS or FLACS in Severance Hospital between September 2019 and July 2021. Optical coherence tomography was performed before and 1 month after surgery. …”
    Get full text
    Article
  10. 190

    Coseismic and postseismic slip of the 2005 Mw8.6 Nias‐Simeulue earthquake : spatial overlap and localized viscoelastic flow by Qiu, Qiang, Feng, Lujia, Hermawan, Iwan, Hill, Emma M.

    Published 2020
    “…This localized viscoelastic flow coincides with a low-velocity zone below Toba volcano, as imaged by tomography studies; it is possible that the viscoelastic flow beneath the volcano accelerated following this event.…”
    Get full text
    Journal Article
  11. 191

    Non-local means improves total-variation constrained photoacoustic image reconstruction by Yalavarthy, Phaneendra K., Kalva, Sandeep Kumar, Pramanik, Manojit, Prakash, Jaya

    Published 2021
    “…Photoacoustic/Optoacoustic tomography aims to reconstruct maps of the initial pressure rise induced by the absorption of light pulses in tissue. …”
    Get full text
    Journal Article
  12. 192

    New possibilities in polymer binder jetting additive manufacturing via infiltration and warm isostatic pressing by Park, Seong Jun, Ju, Ho Gi, Park, Seong Je, Hong, Sukjoon, Son, Yong, Ahn, Il Hyuk

    Published 2023
    “…In addition, the results of transmission, scanning electron microscopy, and microcomputer X-ray tomography reveal a clear decrease in the number of voids.…”
    Get full text
    Journal Article
  13. 193

    Low-velocity impact response of sandwich structures with cores made from entangled metallic wire material - silicone rubber composites by Zheng, Xiaoyuan, Xiao, Zhongmin, Ren, Zhiying, Zi, Bao, Bai, Hongbai, Wu, Yiwan, Yao, Liming

    Published 2024
    “…Additionally, visual observation and computerized tomography scans were employed to characterize the damage mechanisms. …”
    Get full text
    Journal Article
  14. 194

    Modeling of Mechanical Stress Exerted by Cholesterol Crystallization on Atherosclerotic Plaques by Luo, Yuemei, Cui, Dongyao, Yu, Xiaojun, Chen, Si, Liu, Xinyu, Tang, Hongying, Wang, Xianghong, Liu, Linbo

    Published 2017
    “…Using micro-optical coherence tomography (μOCT), we extracted the cross-sectional geometric information of cholesterol crystals in human atherosclerotic aorta tissue ex vivo and applied the information to the model. …”
    Get full text
    Get full text
    Journal Article
  15. 195

    Effect of Topically Administered Chitosan-N-acetylcysteine on Corneal Wound Healing in a Rabbit Model by Fischak, Corinna, Klaus, Robert, Werkmeister, René M., Hohenadl, Christine, Prinz, Martin, Schmetterer, Leopold, Garhöfer, Gerhard

    Published 2017
    “…Monitoring of corneal wound healing was performed with ultra-high-resolution optical coherence tomography (OCT) and epithelial fluorescein staining. …”
    Get full text
    Get full text
    Journal Article
  16. 196

    The anatomy of Westlothiana lizziae and a novel phylogenetic analysis of early amniotes by Igielman, B

    Published 2024
    “…</p> <br> <p>Here I use phase-contrast synchrotron computed-tomography to reveal considerable new data on the enigmatic early Carboniferous stem-amniote <em>Westlothiana lizziae</em>, which was originally described as a “reptiliomorph”. …”
    Thesis
  17. 197

    Wavelet-based compression of medical images: Filter-bank selection and evaluation by Saffor, A., Bin Ramli, A.R., Ng, K.H.

    Published 2003
    “…In this study a variety of wavelet filters are used to compress and decompress computed tomography (CT) brain and abdomen images. We applied two-dimensional wavelet decomposition, quantization and reconstruction using several families of filter banks to a set of CT images. …”
    Article
  18. 198

    Dosimetric study of fletcher’s applicator in high-dose-rate (HDR) brachytherapy for cervical cancer: TLD measurements in pelvic water phantom by Sallehudin,, Muhammad Nursyabil

    Published 2024
    “…Materials and Method: The eight sets of thermoluminescence dosimeters (TLD), calibrated using an Iridium-192 source, were placed across the bladder and rectum organ at risk (OAR) inside the heterogenous pelvic water phantom and computed tomography (CT) scanned for image acquisition. The planning of the cervical brachytherapy is done to obtain the calculated TPS dose using the CT image with an 8Gy dose prescription. …”
    Get full text
    Monograph
  19. 199

    Dose verification of 3D printed male pelvic phantom for radiotherapy quality assurance by Maniam, Peraveen M

    Published 2024
    “…In this study, the phantom material was characterized by its physical density and computed tomography (CT) numbers and profile. In addition, dose verification was conducted using the phantom with thermoluminescent dosimeter-100 (TLD-100) and ionisation chamber. …”
    Get full text
    Monograph
  20. 200

    A comprehensive 3D dosimetric analysis of the vienna ring applicator in high-dose-rate (HDR) brachytherapy for cervical cancer treatment: TLD measurement by Sivaprakasam, Pugalya

    Published 2024
    “…Methods and Materials: A Vienna Ring applicator was assembled in a pelvic phantom with Thermoluminescence Dosimeters (TLD-100) chips were attached to the OARs (bladder and rectum) to act as markers. Computed Tomography (CT) images were obtained for treatment planning. 7Gy was prescribed for irradiation and the treatment was planned for the assessment of dose received by target, OAR and the TLDs at 8 points. …”
    Get full text
    Monograph