341
Kinetic performance of cross-linked enzyme aggregates (clea)-amylase from Zophobas morio
Published 2016“…For CLEA-amylase, Hanes-Woolf plot had showed the best fitted model based on R2 with Vmax= 1.068 mM/min and KM= 0.182 mM. Lineweaver-Burk plot was used to obtain the kinetic parameters for free amylase, with Vmax and KM of 17.230 mM/min and 2.470 mM, respectively. …”
Get full text
Proceeding Paper -
342
Investigation of bioflocculant as renewable dewatering aid in sludge treatment
Published 2016“…Results showed that salt extraction by NaCl gave the best results of 0.41 cm/min of settling velocity and 63.39 mg/L of SVI. …”
Get full text
Proceeding Paper -
343
The effect of incorporating lithium fluoride on the compressive strength and diametric tensile strength of glass ionomer cement
Published 2011“…The specimens were tested in a Universal Testing Machine (Instron 1122, Instron corp., High Wycombe, U.K.) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. …”
Get full text
Get full text
Article -
344
Adsorption of copper, nickel and lead ions from synthetic semiconductor industrial wastewater by palm shell activated carbon
Published 2010“…The percentage metal removal approached equilibrium within 30 min for lead, 75 min for copper and nickel, with lead recording 100 %, copper 97 % and nickel 55 % removal, having a trend of Pb2+ > Cu2+ > Ni2+ . …”
Get full text
Article -
345
Assessment of heavy metals in Malacca river water using electrokinetic technique
Published 2020“…The optimal removal was observed at a voltage of 90 V, with an electrode distance of 10cm and operational time of 30 min. The pH water was acidic which below than 7 after the electrokinetic process. …”
Get full text
Book Section -
346
Penghasilan manual rjngkas penggunaan alat Total Station Sokkia Set5f dan Perisian Sdr Mapping & Design untuk automasi ukur topografi
Published 2002“…Analisis data dilakukan menggunakan perisian SPSS versi 11.0. Hasil analisis skor min menunjukkan kesemua responden bersetuju bahawa manual dalam bentuk buku ini menarik Min ( M ) ^ ^ dan Sisihan Piawai (SD) = .535 tetapi kurang interaktif (M) = 2.29 dan (SD) = 0.488. …”
Get full text
Get full text
Get full text
Thesis -
347
-
348
-
349
-
350
Optimization of supercritical carbon dioxide extraction of bioactive flavonoid compounds from spearmint (Mentha Spicata l.) leaves by using response surface methodology
Published 2012“…The optimal conditions were identified as 209.39 bar pressure, 50.00 °C temperature and 7.39 g/min co-solvent amount. The obtained extract under optimum SC-CO2 condition was analysed by high-performance liquid chromatography. …”
Get full text
Get full text
Article -
351
Optimization of ultrasound-assisted extraction of crude oil from winter melon (Benincasa hispida) seed using response surface methodology and evaluation of its antioxidant activity...
Published 2012“…Optimal conditions were identified as 65% power level, 52 °C temperature and 36 min sonication time for maximum crude yield (108.62 mg-extract/g-dried matter). …”
Get full text
Article -
352
Photocatalytic decomposition of acetaldehyde gas on TiO2-SiO2 thin film photocatalyst ― a kinetic analysis
Published 2013“…It is found that the first order reaction rate constant (k) of the TF95/5 thin film photocatalyst (1.2438 µmol dm-3 min-1) is higher than that of TF90/10 thin film (0.3648 µmol dm-3 min-1). …”
Get full text
Article -
353
Supercritical carbon dioxide extraction of oil from Thunnus tonggol head by optimization of process parameters using response surface methodology
Published 2013“…Total oil was extracted from ground fish head of Longtail tuna (Thunnus tonggol) using supercritical carbon dioxide (SC-CO2) at 20 to 40 MPa, 45 to 65 oC and 1 to 3 ml min−1. Response surface methodology (RSM) was employed to optimize the operating conditions of the SC-CO2 technique where the highest oil yield was obtained (35.6% on dry weight basis) at 40 MPa, 65 oC, and 3 ml min−1. …”
Get full text
Article -
354
Dry machining of brass using titanium carbonitride (TiCN) coated tool
Published 2013“…The optimum cutting condition for wet and dry machining of brass using TiCN coated cutting tool was found to be 498 m/min at d = 0.2 mm, f = 0.4 mm/rev. The tool tip temperature obtained from dry machining did not influence tool wear since the temperature rise is quite similar to the wet machining temperatures. …”
Get full text
Article -
355
Bladder scan vs urethral catheterization for measurement of immediate post partum bladder volume
Published 2011“…The mean for time interval between bladder scan and catheterization was 3 min(range between 1-8 min). There is a linear relationship between the bladder scan-estimated and catheter bladder volumes (r2=082). …”
Get full text
Article -
356
Rapid and sensitive LC method for the analysis of Gemifloxacin in Human plasma
Published 2009“…The mixture was then sonicated for 10 min followed by 20 min centrifugation at 5000 rpm (g = 3600). …”
Get full text
Article -
357
Personal control related to childbirth satisfaction among postpartum mothers in Hospital Tengku Ampuan Afzan (HTAA)
Published 2013“…Findings: The mean score for personal control among postnatal mother was 52.56 [SD = 10.693, min max (29, 70)] with the mean childbirth satisfaction score of 140.06 [SD = 17.109, min max (89, 170)]. …”
Get full text
Proceeding Paper -
358
Effect of peak current on material removal rate for electrical discharge machining of non-conductive Al2O3 ceramic
Published 2014“…MRR was found to be 0.052 mm3/min at peak current 1.1 A and it was found to be 0.132 mm3/min at peak current 1.3 A.…”
Get full text
Get full text
Article -
359
Coal-fired power plant airborne particles impact towards human health
Published 2015“…Manjung coal-fired power plant emission had been recognised as one of the potential anthropogenic sources of airborne particles. 8-hours airborne particles sampling had been done at Manjung Power Plant in March and July 2011 with 7-hole sampler at 2 L/min air flow and cyclone sampler at 2.2 L/min airflow. …”
Get full text
Article -
360
Reaction kinetics of free and immobilized β-glucosidase in alginate gel
Published 2013“…Michaelis constants obtained from linearized Langmuir plot are: vmax and Km as 21.10 μmol/mL.min and 0.0148 mol/L respectively for immobilized enzyme; vmax and Km for free enzyme were obtained as 24.33 μmol/mL.min and 0.0073 mol/L respectively. …”
Get full text
Get full text
Get full text
Proceeding Paper