-
1
Al2O3-Cu hybrid nanofluid flow and heat transfer characteristics in the duct with various triangular rib configurations
Published 2024“…Key findings include: (1) the 60° rib configuration produced the highest local heat transfer coefficient, with the maximum occurring at the rib centers. (2) Increasing nanofluid concentration and Reynolds number enhanced heat transfer but reduced skin friction. (3) The optimal performance was achieved with 2 vol.% Al2O3–Cu at Re = 60,000. (4) Velocity contours revealed larger recirculation zones for 60° ribs compared to 45° and 90° configurations. (5) Turbulent kinetic energy was highest for 60° ribs, contributing to enhanced thermal performance. …”
Article -
2
Ultrasonographic imaging study on abdominal organs of goat
Published 2016“…For the reticulum, its wall was examined at the ventral abdomen at the 6th ICS just caudal to the xiphoid and the abomasum wall was examined at the ventral part of the 7th ICS while for the omasum, it was examined at the 8th ICS. …”
Get full text
Project Paper Report -
3
Low-energy channel for mass transfer in Pt crystal initiated by molecule impact
Published 2021Get full text
Journal Article