Oxygen Stripping in Deaerator Feed Water: Condensation on Spray Droplets

Deaerator is used to remove oxygen from boiler feed-water. Experiments with deaerator indicate that the droplet diameter decreases with increasing the mass flow rate of water and the increasing deaerator pressure leads to increase in heat and mass transfer coefficients. The mass transfer coefficient...