Thermally-Induced Crack Evaluation in H13 Tool Steel
This study reported the effect of thermal wear on cylindrical tool steel (AISI H13) under aluminum die-casting conditions. The AISIH13 steels were immersed in the molten aluminum alloy at 700 �C before water-quenching at room temperature. The process involved an alternating heating and cooling of...