Analysis of the Causes of the Emergency Shutdown of Natural Gas-Fired Water Peak Boilers at the Large Municipal Combined Heat and Power Plant
The paper presents a cause-and-effect analysis of the failure of a 130 MWt gas-fired water boiler. The fault was a rupture of the helically finned tubes in the first rows of the second-stage water heater (ECO2). The high frequency of failures forced the boiler user to investigate their causes. The r...