Study of crack detection probability for maintenance reliability of power plant (Estimation of crack detection probability on the damage probability)
This paper discuss about suitable damage size that should be detected by ultrasonic testing (UT) for nuclear power plant piping when consider about propagation of IGSCC. The power plant piping loop is inspected using UT as an in-service inspection (ISI). The reliability of UT result is affected by e...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Japanese |
Published: |
The Japan Society of Mechanical Engineers
2016-12-01
|
Series: | Nihon Kikai Gakkai ronbunshu |
Subjects: | |