Effects of decay heat and cooling condition on the reactor pool natural circulation under RVACS operation in a water 2-D slab model

The temperature distribution of the reactor pool under natural circulation induced by the RVACS operation was experimentally studied. According to the Bo’ based similarity law, which could reproduce the temperature distribution of the working fluid under natural circulation, SINCRO-2D facility was d...

Full description

Bibliographic Details
Main Authors: Min Ho Lee, Dong Wook Jerng, In Cheol Bang
Format: Article
Language:English
Published: Elsevier 2023-05-01
Series:Nuclear Engineering and Technology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1738573323000633