Analysis of electromagnetic performance of the interior permanent magnet brushless DC motor with stator slot skewed structure based on quasi-3D moving electromagnetic-field circuit coupling calculation

This paper takes a 50 kW interior permanent magnet brushless DC motor as an example, and explores the influence of the degree of stator slot skew on the overall motor magnetic density and air gap magnetic density; then reveals the influences of stator slot skewed structure on a series of key electro...

Full description

Bibliographic Details
Main Authors: Xue-gui Gan, Zhen-nan Fan, Jing-can Li
Format: Article
Language:English
Published: Polish Academy of Sciences 2022-03-01
Series:Archives of Electrical Engineering
Subjects: