Localization of CO2 Leakage from a Circular Hole on a Flat-Surface Structure Using a Circular Acoustic Emission Sensor Array

Leak localization is essential for the safety and maintenance of storage vessels. This study proposes a novel circular acoustic emission sensor array to realize the continuous CO2 leak localization from a circular hole on the surface of a large storage vessel in a carbon capture and storage system....

Full description

Bibliographic Details
Main Authors: Xiwang Cui, Yong Yan, Miao Guo, Xiaojuan Han, Yonghui Hu
Format: Article
Language:English
Published: MDPI AG 2016-11-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/16/11/1951