Active Tendon Control of Stay Cable by a Giant Magnetostrictive Actuator Considering Time-Delay
Active control of a stay cable through changing its tension is an effective way to lower the vibration amplitude. In this paper, active tendon control of a stay cable using a giant magnetostrictive actuator (GMA), which can generate axial deformation in a short period (normally less than 10 ms) unde...