Intraprosthetic Dislocation of a Modular Dual-Mobility Total Hip Arthroplasty With Posterior Migration of the Polyethylene Liner
Dual-mobility (DM) implants have been used in total hip arthroplasty since 1974. Modular DM implants have seen an increase in use in primary and revision total hip arthroplasties given the theoretical decreased dislocation rate. DM constructs have 2 articulation sites, one between the acetabular she...