Minimal fixed flow anesthesia for off-pump coronary artery bypass surgery: A parallel randomized trail

Objectives: The aim of the present study was to test a safety of a fixed minimal (0.5 l/min) fresh gas flow (FGF) anesthesia as a method ensuring adequate oxygenation during off-pump coronary artery bypass grafting operations. Design: A randomized, prospective study. Setting: Single-center clinical...

Full description

Bibliographic Details
Main Authors: Ioseb Begashvili, Merab Kiladze, Christina Ejibishvili, George Grigolia
Format: Article
Language:English
Published: Elsevier 2023-11-01
Series:Heliyon
Online Access:http://www.sciencedirect.com/science/article/pii/S2405844023093891