Misidentification of preformed anti-HLA-DP antibodies leads to antibody-mediated kidney transplant rejection: a case report
Abstract Background Patients who are HLA-sensitized are at high risk for early antibody-mediated rejection (AMR) and worse outcomes. Therefore, it is crucial to detect the presence of donor-specific antibodies (DSAs) using pretransplant antibody identification and crossmatch assays. An error in anti...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2022-05-01
|
Series: | BMC Nephrology |
Subjects: | |
Online Access: | https://doi.org/10.1186/s12882-022-02807-6 |