Influence of ECAP Parameters on Electrical Conductivity and Hardness of Pure Cu

In this study, the ECAP process was conducted using two different dies of channel angles (Φ) 120° and 90° to extrude pure Cu for 2 and 6 passes of route Bc at room temperature. Optical Microscopy (OM) was used to study the microstructure of Cu before and after ECAP processing. Vicker’s microhardness...

Full description

Bibliographic Details
Main Authors: mahmoud EL-Shenawy, Waleed. H. El-Garaihy, Medhat Elhadek, Mohamed zaki, Ahmed Nassef
Format: Article
Language:English
Published: Port Said University 2022-12-01
Series:Port Said Engineering Research Journal
Subjects:
Online Access:https://pserj.journals.ekb.eg/article_256707_020a5665fab4c78730441fadea1f33ab.pdf
_version_ 1827787113538519040
author mahmoud EL-Shenawy
Waleed. H. El-Garaihy
Medhat Elhadek
Mohamed zaki
Ahmed Nassef
author_facet mahmoud EL-Shenawy
Waleed. H. El-Garaihy
Medhat Elhadek
Mohamed zaki
Ahmed Nassef
author_sort mahmoud EL-Shenawy
collection DOAJ
description In this study, the ECAP process was conducted using two different dies of channel angles (Φ) 120° and 90° to extrude pure Cu for 2 and 6 passes of route Bc at room temperature. Optical Microscopy (OM) was used to study the microstructure of Cu before and after ECAP processing. Vicker’s microhardness was measured along the transvers section of the Cu billets. The electrical conductivity of the Cu billets was measured at room temperature and expressed as a relative percentage of the international annealed copper standard. 2-passes using the two dies revealed an elongated ultrafine-grained structure that aligned parallel to the extrusion direction. 6 passes using the 90°-die resulted in more ultrafine-grained equiaxed structure compared to the Cu billets processed through the 120°-die. Processing through 6-passes revealed a significant increase in the Cu Vicker’s microhardness by 56% and 72% through processing using the using the 120°-die and 90°-die, respectively when it put in comparison with the as-annealed samples. The electrical conductivity finding revealed that ECAP processing up to 6-passes resulted in insignificant decrease of 6.6% compared to the as-annealed counterpart which indicated that ECAP processing can strengthen the Cu billets without losing its electrical conductivity
first_indexed 2024-03-11T16:43:59Z
format Article
id doaj.art-123e52de64ec4b2da8578297756f3bd2
institution Directory Open Access Journal
issn 1110-6603
2536-9377
language English
last_indexed 2024-03-11T16:43:59Z
publishDate 2022-12-01
publisher Port Said University
record_format Article
series Port Said Engineering Research Journal
spelling doaj.art-123e52de64ec4b2da8578297756f3bd22023-10-23T05:54:44ZengPort Said UniversityPort Said Engineering Research Journal1110-66032536-93772022-12-01264424910.21608/pserj.2022.156882.1194256707Influence of ECAP Parameters on Electrical Conductivity and Hardness of Pure Cumahmoud EL-Shenawy0Waleed. H. El-Garaihy1Medhat Elhadek2Mohamed zaki3Ahmed Nassef4باحث دکتوراه بقسم هندسه الانتاج و التصمیم المیکانیکى کلیه الهندسه جامعه بورسعیدMechanical Engineering Department, Faculty of Engineering, Suez Canal University, Ismailia, Egypt. Mechanical Engineering Department, College of Engineering at Al Kharj, Prince Sattam Bin Abdulaziz University, Al Kharj 11942, Saudi Arabia,Port Said UniversityMechanical Engineering Department, Faculty of Engineering, Suez Canal University, Ismailia 41522, Egypt, Mechanical Engineering Department, College of Engineering at Al Kharj, Prince Sattam Bin Abdulaziz University, Al Kharj 11942, Saudi Arabia,Department of Production and Mechanical Design Engineering, Faculty of Engineering, Port-Said University, Port-Fouad, Port-Said 42523, EgyptIn this study, the ECAP process was conducted using two different dies of channel angles (Φ) 120° and 90° to extrude pure Cu for 2 and 6 passes of route Bc at room temperature. Optical Microscopy (OM) was used to study the microstructure of Cu before and after ECAP processing. Vicker’s microhardness was measured along the transvers section of the Cu billets. The electrical conductivity of the Cu billets was measured at room temperature and expressed as a relative percentage of the international annealed copper standard. 2-passes using the two dies revealed an elongated ultrafine-grained structure that aligned parallel to the extrusion direction. 6 passes using the 90°-die resulted in more ultrafine-grained equiaxed structure compared to the Cu billets processed through the 120°-die. Processing through 6-passes revealed a significant increase in the Cu Vicker’s microhardness by 56% and 72% through processing using the using the 120°-die and 90°-die, respectively when it put in comparison with the as-annealed samples. The electrical conductivity finding revealed that ECAP processing up to 6-passes resulted in insignificant decrease of 6.6% compared to the as-annealed counterpart which indicated that ECAP processing can strengthen the Cu billets without losing its electrical conductivityhttps://pserj.journals.ekb.eg/article_256707_020a5665fab4c78730441fadea1f33ab.pdfecapdie90die120pure copper
spellingShingle mahmoud EL-Shenawy
Waleed. H. El-Garaihy
Medhat Elhadek
Mohamed zaki
Ahmed Nassef
Influence of ECAP Parameters on Electrical Conductivity and Hardness of Pure Cu
Port Said Engineering Research Journal
ecap
die90
die120
pure copper
title Influence of ECAP Parameters on Electrical Conductivity and Hardness of Pure Cu
title_full Influence of ECAP Parameters on Electrical Conductivity and Hardness of Pure Cu
title_fullStr Influence of ECAP Parameters on Electrical Conductivity and Hardness of Pure Cu
title_full_unstemmed Influence of ECAP Parameters on Electrical Conductivity and Hardness of Pure Cu
title_short Influence of ECAP Parameters on Electrical Conductivity and Hardness of Pure Cu
title_sort influence of ecap parameters on electrical conductivity and hardness of pure cu
topic ecap
die90
die120
pure copper
url https://pserj.journals.ekb.eg/article_256707_020a5665fab4c78730441fadea1f33ab.pdf
work_keys_str_mv AT mahmoudelshenawy influenceofecapparametersonelectricalconductivityandhardnessofpurecu
AT waleedhelgaraihy influenceofecapparametersonelectricalconductivityandhardnessofpurecu
AT medhatelhadek influenceofecapparametersonelectricalconductivityandhardnessofpurecu
AT mohamedzaki influenceofecapparametersonelectricalconductivityandhardnessofpurecu
AT ahmednassef influenceofecapparametersonelectricalconductivityandhardnessofpurecu