Analysis of Current Signals in a Partially Demagnetized Vector Controlled Interior Permanent Magnet Generator

This manuscript analyzes the operation of an interior permanent magnet (IPM) machine working as a permanent magnet synchronous generator (PMSG). The partial demagnetization operation is analyzed. To obtain more accurate voltages and currents of the machine, finite element analysis (FEA) is used in c...

Full description

Bibliographic Details
Main Author: Quintal-Palomo Roberto Eduardo
Format: Article
Language:English
Published: Sciendo 2019-06-01
Series:Power Electronics and Drives
Subjects:
Online Access:http://www.degruyter.com/view/j/pead.2018.4.issue-1/pead-2019-0012/pead-2019-0012.xml?format=INT