Patient-Specific Instrument Guided Double Chevron-Cut Distal Femur Osteotomy
The risk of non-union and prolonged periods of protected weight-bearing still remain unsolved issues after distal femur osteotomy (DFO). To improve the stability, we developed the double chevron-cut technique, which is a modified medial closing-wedge DFO guided by a patient-specific instrument. The...